C.E. Niehoff & Co. C190 Installation

C190 Series Alternators
for Use in Hazardous Locations
Installation Instructions
Repair of this equipment shall only be carried out by C.E. Niehoff & Co.
This symbol is used to indicate presence
of hazards that can cause severe personal injury, death or substantial property damage.
Contact C.E. Niehoff & Co. for:
• Sira IECEx Certificate of Conformity IECEx SIR 09.0144X
• SIR A ATEX Cer tificate of Conformity Sira 09ATEX1345X
• Quality Assurance Cer tificate of Conformity Sira 0518
The alternator incorporates flameproof joints with dimensions that are other than the relevant maximum or minimum, specified in Table 1 or IEC 60079 -1. The user shall contact the original manufacturer for infor­mation on the dimensions of the f lameproof joints.
The user shall refer to the manufacturer’s instructions with respect to the enclosure providing a degree of ingress protection IP66.
MODEL, VDC, ADC, ISOL GND
Figure 1 – Alternator Nameplate Data
The alternator contains no user serviceable
parts. DO NOT DISMANTLE. Failure to observe any instructions in the installation instruction may invalidate any certificate or warranty agreement.
DO NOT DISASSEMBLE. The cover O-ring may
dislodge and cause failure of the flameproof protection features. Verify that there is NOT a gap between the cover and the alternator hous­ ing. Torque the nine cover bolts (M6x1x25 6g Class 12.9. DIN 912) to 13.5 Nm/120 lb.in., which incorporate a steel zinc-plated washer (7.10x
12.00 -12.12x 1.0mm thick) complete with bonded seal provided with each bolt.
1. Gland and cable and pulley/fan are specified and ordered separately and are factory-installed. Cable and gland have their own application requirements.
Cable entry temperature may be 40º C above ambient—cable to be suitable.
TABLE 1—Conductor Sizes
Provision Internal Earthing Bonding conductor size = CSAMIN
*CSAMAX16mm2 (5.5 Awg) CSAMIN≥ CSAMIN
1
16mm2<CSAMAX35mm
2
(2 Awg)
CSAMAX>35mm2 (2 Awg) CSAMIN≥0.5 x CSAMAX
3
* Cross Sectional Area (CSA) of largest cable conductor = (CSAMAX)
Provision
External Earthing Bonding conductor size = CSAMIN
CSAMIN4.0mm2(11.5 Awg) CSAMIN=[8 Awg (8.4mm2)
1
2
CSAMIN16mm2 (5.5 Awg)
INSTALLED]
Installation Instructions
Explosion hazard. Do not open when an explosive
atmosphere is present. Improper installation of alternator in an explosive environment can cause severe personal injury, death, or substantial property damage. Alternator must be installed by a qualified person trained and familiar with requirements for selection, installation, and maintenance of flame­ proof equ ipment to IEC 60079 -14 and IEC 60 079-17 respectively.
“Person In Authority” is def ined as the employee of a company taking full responsibility for the safety, welfare, and super vision of all other employees under their control. (See Inspection and Mainte­ nance Section referenced above.)
Page 1 of 4
2 Mount alternator on a suitable bracket and secure
with hardware per alternator drawing on page 2 of these instructions.
3. Ground bolt torque is 14.9 Nm/132 lb. in. Clean sur­faces of all corosion and apply a suitable corrosion inhibitor over ground connction for protection.
4. Secure output and ground cables within 12 inches (300mm) of gland or terminal to prevent rotation and loosening of cable at terminal.
5. Connect output cable from alternator to connections as shown in diagram on page 4.
6. Perform a final inspection on the installation.
7. Install suitable alternator drive belt.
8. Start engine. Confirm the operation of charging system meets specification.
II154E
Page 2 of 4
Figure 2 – Alternator Outline Drawing
II154E