NOTICE
This sensor/wire assembly is used to replace the temperature sensor black wire (B terminal) when necessary on various CEN temperature-voltage sense wiring harnesses (with or without other external connections such as J1939 connections). For more information, see CEN Service Bulletin SB27.
A9-4056
Temperature Sensor
Replacement Instructions
1. Make sure master battery switch has been turned off on vehicle.
2. Disconnect temperature-voltage sense harness at both B+ and B terminals at battery.
3. From black wire on existing harness, cut off first six inches on B terminal end, which includes the sensor.
4. Strip 1/4” from the shortened black wire on the harness. Crimp one end of insulated butt splice on shortened wire.
5. Crimp end of new sensor/wire assembly on other end of butt splice.
6. Use heat gun to seal spliced ends.
7. Re-attach new black wire in harness to battery negative post and existing red wire to 14V battery positive post for 14 V systems or 28 V battery positive post for 28 V systems.
2. Reconnect master battery switch and test charging system for proper function.
Butt splice
A9-4056 Temperature sensor replacement assembly (black wire)
Figure 1 - Temperature Sensor Replacement Details
If you have questions about your a lternator or a ny of these instructions, or i f you need to locate a Factory Authorized Service Dealer, please contact us at:
TEL: 800.643.4633 USA and Canada • TEL: 847.866.6030 outside USA and Canada • FAX: 847.492.1242
Page 1 of 1
C. E. Niehoff & Co.• 2021 Lee Street • Evanston, IL 60202 USA
E-mail us at service@CENiehoff.com
II224A