C.E. Niehoff & Co. A9-307 Instructions

A9-307 Alternator Voltage Filter Assembly
Installation Instructions
TURN OFF
BATTERY DISCONNECT SWITCH
BEFORE PROCEEDING
2. Remove and save one screw from top of drive end (DE) control box (see Figure 1).
B+ cable from vehicle
3. See Figure 2. Connect leads of A9-307 assembly:
Red lead to B+ terminal as shown in stacking order. Torque terminal nut to 32 Nm/24 lb. ft.
• Black lead to top of control box (ref. step 2). Torque to 2.3 Nm/20 lb. in.
4. Replace red boot on B+ terminal.
5. Using cable ties, securely support the assembly to the vehicle B+ cable as shown in Figure 1.
See step 2
Red boot
Black lead from A9-307 assembly
Red lead from A9-307 assembly
A9-307 alternator voltage fi lter assembly
Cable ties securing A9-307 assembly
Figure 1 – C706 Alternator with A9-307 Assembly Installed
Black lead from A9-307 assembly
B+ cable terminal
Red lead from
A9-307 assembly
Insulator Flat washer
Lock washer
B+ bolt
Figure 2 – Top View of A9-307 Alternator Voltage Filter Assembly Stacking Order
Red boot
C. E. Niehoff & Co. • 2021 Lee Street • Evanston, IL 60202 Tech Services Hotline 800-643-4633
Page 1 of 1
II0158B