C.E. Niehoff & Co. C520, A2-326 Installation

A9-4000 & A9-4001 Extended Wiring Harnesses
for Remote-Mounted A2-326 Regulator
with C520 Alternator
Installation Instructions
1. Before installing regulator, make sure battery-age switch on back of regulator is set for appropriate battery age in years. See Table 1 and Figure 1. Then install regulator in location determined by vehicle manufacturer.
2. Connect 20-ft. A9-4000 extended wiring harness between regulator and alternator. Make sure harness plugs are securely connected to regulator and alternator sockets. See Figure 2.
3. Using cable ties every 12-14 inches, securely support wiring
Table 1 — Battery-Age
Setpoints on Regulator
Setpoint Battery Age (Years)
1 New
2 1
3 2
4 3+
harness between alternator and regulator.
4. Connect A9-4001 battery sense harness to J1939 connector on regulator.
5. Complete remaining connections from battery sense harness as shown in Figure 2.
C520 Alternator
A9-4000 Extended wiring harness
A2-326 Regulator
2
3
1
4
Figure 1 –
4 Battery-Age
Setpoints
J1939/11 Connector
A9-4001 Battery sense harness
Battery current sensor: current sensor can be placed on positive or negative battery cable but battery CHARGING current should fl ow in direction shown
Fuseholder w/1 amp fuse included
Black wire
Red wire
Connect to battery negative post or busbar (3/8 dia)
Connect to battery positive post or busbar (3/8 dia)
Figure 2 – Remote-Mounted A2-326 Regulator/C520 Alternator with Extended Wiring Harnesses
Page 1 of 1
II0117A