C.E. Niehoff & Co. A2-149, A2-155 Regulator Installation

A2-149 & A2-155
Regulators
Installation Instructions
Table 1 – Voltage Select Switch Position
4 Voltage Setpoints (Fig. 1)
Position 1 14.0 V
Position 2 14.4 V
Position 3 14.8 V
Position 4 15.5 V
Note: On Group 31 batteries, if boiling or excessive gassing occurs with high voltage setpoint (position 3), change to medium voltage setpoint (position 2).
1. Before installing, turn regulator over and select appropriate voltage setpoint for battery type (See Table 1 and Fig. 1).
2. Install new regulator as described below:
a. Mount new regulator on alternator in the
same position as the previous regulator.
b. Use screws and washers (if supplied).
Torque regulator mounting screws to
8.5 Nm/75 lb. in.
3. Plug the alternator-to-regulator harness into the regulator.
4. A2-155 regulator connections:
Maintenance (D Category)
Maintenance-Free (Group 31)
Maintenance-Free (Group 31)
Battery Isolator setpoint
5. A2-149 regulator connections:
• D+ terminal provides 14 VDC voltage output to multiplex controller. When connecting D+ terminal to controller through a relay, the relay coil must be diode protected and rated for proper voltage. Torque M5 terminal nut on regulator to 4.5 Nm/40 lb. in.
• Connect R terminal to tachometer or relay. R terminal taps AC voltage, typically half the charge voltage. Torque M6 terminal nut on regulator to 4.5 Nm/40 lb. in.
2
3
1
Figure 1 – 4 Voltage Setpoints
4
• Connect IGN terminal to ignition source through existing switch. Torque M5 terminal nut on regulator to 4.5 Nm/40 lb. in.
• Connect P terminal to tachometer or relay. P terminal taps AC voltage, typically half the charge voltage. Torque M6 terminal nut on regulator to 4.5 Nm/40 lb. in.
C. E. Niehoff & Co. • 2021 Lee Street • Evanston, IL 60202 Tech Services Hotline 800-643-4633
II0118BPage 1 of 1