Please read this manual before switching the unit on.
Please read this manual before switching the unit on.
Important
Important safety information inside.
safety information inside.
Page 2
Laser Distance Meter User Manual
www.tools.in.th
www.tools.in.th
Page 3
Laser Distance Meter User Manual
www.tools.in.th
www.tools.in.th
Content
Safety Instruction
1.
2.
3.
4.
5.
6.
7.
8.
9
.
The compact and handy base model was specifically designed for indoor applications.
Shortcut and Soft grip keys for addition, subtraction, area and volume calculation make
measuring fast and very reliable.
• Deactivation of safety systems and removal of explanatory and hazard labels
• Opening of the equipment by using tools (screwdrivers, etc.), as far as not specifically permitted for certain cases
• Carrying out modification or conversion of the product
• Use of accessories from other manufacturers without the express approval of CEM Technology.
• Deliberate or irresponsible behavior on scaffolding, when using ladders, when measuring near machines which
are running, or near parts of machines or installations which are unprotected
• Aiming directly into the sun
• Inadequate safeguards at the surveying site (e.g. when measuring on roads, construction sites, etc.)
4
Page 5
Laser Distance Meter User Manual
www.tools.in.th
www.tools.in.th
Laser Classification
The CEM produced a visible laser beam which emerges from the front of the instrument.
Laser Class 2 products:
Do not stare into the laser beam or direct it towards other people unnecessarily. Eye protection is normally afforded
by aversion responses including the blink reflex.
‘s
WARNING
Looking directly into the beam with optical aids
(e.g. binoculars, telescopes) can be hazardous.
Precautions:
Do not look directly into the beam with optical aids.
:
CAUTION:
Looking into the laser beam may be hazardous to the eyes.
Precautions:
Do not look into the laser beam. Make sure the laser is aimed above or below eye level.
5
Page 6
Laser Distance Meter User Manual
www.tools.in.th
www.tools.in.th
2 Start-Up.
Inserting/Replacing Batteries
1) Remove battery compartment lid.
2) Insert batteries, observing correct polarity.
3) Close the battery compartment again.
•
Replace the batteries when the symbol ““ flashes permanently
in the display.
•
• Use alkaline batteries only.
• Remove the batteries before any long period of non-use to avoid
the danger of corrosion
Area measurement
Volume measurement
Indirect measurement
Indirect (second) measurement
5- Single distance measurement
6- Battery status
7- Historical memory
8- Instrument error warning
9- Continuous measurement & Max and Min measurement
10- First value display line
11- Second value display line
12- Summary line for last measure or calculation result
Laser Distance Meter User Manual
56 7 8
9
1
2
3
4
Figure C
10
11
12
7
Page 8
Laser Distance Meter User Manual
www.tools.in.th
www.tools.in.th
.3 Initial Operation and Setting
Switching On and Off
Switches on the instrument and laser.
Press this button longer to switch off the instrument.
The instrument switches off automatically after three minutes of inactivity.
Clear Button
The last action is cancelled or the data display is cleared. If in the mode of History storage, press Storage
button and Clear button simultaneously will clear all storage data in the memory.
Reference Level Setting (See “Figure D”)
The default reference setting is from the rear of the instrument.
Press this buttonto take the selection from the front edge,
A special beep sounds whenever the reference setting is changed.
After a re-startup the reference returns automatically to the default
setting (rear reference).
8
Figure D
Page 9
Laser Distance Meter User Manual
www.tools.in.th
www.tools.in.th
Display Illumination
Click illuminationbutton of the display can be switched on or off, user can trigger the function when
he/she is in darkness situation. The value is clear visible on the LCD
Distance Unit Setting For Instrument
Click the button longer to change the next type of unit,then continueclick the button for
the next unit selection
/UNITS
m, ft. in, ft+in
to
9
Page 10
Laser Distance Meter User Manual
www.tools.in.th
www.tools.in.th
.4 Measuring
Single Distance Measurement
Press to activate the laser.
Press again to trigger the distance measurement. The measured value is displayed immediately.
Continuous Measurement (Tracking) & Max and Min Measurement (See “Figure E”)
The continuous measurement function (tracking) is used for the
transferring of measurements, e.g., from construction plans. In
continuous measurement mode, the measuring tool can be moved
to the target, whereby the measured value is updated approx. every
0.5 seconds in the third line. The corresponding minimum and
maximum values are displayedin the first and second
line. As an example, the user can move from a wall to the required
distance, while the actual distance can be read continuously. For
continuous measurement, push buttonuntil the indicator for
continuous measurement appears in the display. And press MEAS
or Clear button again to stop the function. The function is terminated
automatically after continuous 100 times measurement.
10
dynamically
MIN
MAX
Figure E
Page 11
Laser Distance Meter User Manual
www.tools.in.th
www.tools.in.th
.5 Functions
Addition / Subtraction
Distance measuring.
The next measurement is added to the previous one
The next measurement is subtracted from the previous one
The last step is cancelled.
Return to the single distance measurement
Area Measurement
Press the Area/Volume button. Thesymbol appears in the display.
Pressbutton to take the first length measurement (e.g. length).
Pressagain to take the second length measurement (e.g. width).
The result of the area measurement is displayed in the third line, the individually measured values are displayed in
lines 1 and 2.
.
.
11
Page 12
Laser Distance Meter User Manual
www.tools.in.th
www.tools.in.th
Volume Measurement
For volume measurements, push Area/Volume button twice until theindicator for volume measurement appears
in the display. Afterwards,
press to takes first distance measurement (e.g. length)
press to takes second distance measurement(e.g. width)
The result of the area measurement from the values already measured is displayed in the summary line.
Press to takes the third distance measurement(e.g. height). The value is displayed in the second line.
The result of the area measurement is displayed in the third line, the two previously measured values in lines 1 and 2.
12
,
Page 13
Laser Distance Meter User Manual
www.tools.in.th
www.tools.in.th
Indirect Measurement
Indirect measurement - determining a distance using 2 auxiliary measurements
e.g. when measuring heights that require the measurement of two or three measurements as following step:
Press this buttononce, the displayshows.
Aim at the upper point (1) and trigger the measurement.
After the first measurement the value is adopted. Keep the instrument
as horizontal as possible.
Press to measurement the distance result of the horizontal point (2).
The result of the function is displayed in the summary line.
The distance to be measured flashes in the symbol.
. (See ”Figure G”).
1
2
Figure G
13
Page 14
Laser Distance Meter User Manual
www.tools.in.th
www.tools.in.th
Indirect Measurement - Determining a Distance Using 3 Measurements
Press this buttontwice; the display shows theThe distance to be measured flashes in the symbol.
Aim at the lower point (1) and trigger the measurement. After the
first measurement the value is adopted. Keep the instrument as horizontal
as possible.
Press to measurement the distance result of the horizontal point (2).
ress to measurement the distance result of the upper point (3).
P
The result of the function is displayed in the summary line.
Historical Storage
the previous 20 records (measurements or calculated results) are shown
in the reverse order. Use theorbuttons to navigate through these
records.
You can clear all records by press Storage button and Clear button simultaneously
in historical storage mode.
14
symbol.
(See”Figure H”)
3
2
1
Figure H
3
2
1
Figure I
Page 15
6.Technical Data
www.tools.in.th
www.tools.in.th
Technical Specifications
Range
Measuring accuracy up to 10m
σ
(2 , standard deviation)
Measuring units
Laser Class
Laser Type
Area, Volume Calculations
Indirect measurement using Pythagoras
Addition/Subtraction
Continuous Measurement
Min/Max Distance Tracking
Display illumination and multi-line display
Beep indication
Dust Protect/Splash proof
History measurement records
0.05 to 40m
Typically: ±1.5 mm*
(± 0.06 in )
m,in,ft
Class II
635 nm, <1mW
•
•
•
•
•
•
•
IP 54
1
0
*(0.15 ft to 131ft*)
**
Laser Distance Meter User Manual
*
15
Page 16
Laser Distance Meter User Manual
www.tools.in.th
www.tools.in.th
Keyboard Type
Operating Temperature
Storage Temperature
Battery Life
Batteries
Auto. laser switch-off
Auto instrument switch-off
Dimension
Weight
* Use a target plate to increase the measurement range during daylight or if the target has poor reflection properties!
** in favourable conditions (good target surface properties, room temperature) up to 10 m (33 ft). In unfavourable
conditions, such as intense sunshine, poorly reflecting target surface or high temperature variations, the deviation
over distances above 10 m (33 ft) can increase by ± 0.15 mm/m (± 0.0018 in/ft).
16
Super Soft-Touch (Long life)
0°C to 40°C(32°F to 104°F)
-10°C to 60°C(14°F to 140°F)
up to 4,000 measurements
Type AAA 2 x 1.5V
after 0.5 min
after 3 min
115x48x28mm
135g
Page 17
Laser Distance Meter User Manual
www.tools.in.th
www.tools.in.th
7.Troubleshooting – Causes and Corrective Measures
Code
204
208
209
252
253
255
Cause
Calculation error
Received signal too weak,
measurement time too long.
Distance >50m
Received signal too strong
Temperature too high
Temperature too low
Hardware error
Corrective measure
Repeat procedure
Use target plate
Target too reflective(use target plate)
Cool down instrument
Warm up instrument
Switch on/off the device several times,
If the symbol still appears, please contact
your dealer for assistance.
17
Page 18
Laser Distance Meter User Manual
www.tools.in.th
www.tools.in.th
8.Measuring Sonditions
Measuring Range
The range is limited tom.
At night or dusk and if the target is in shadow the measuring range without target plate is increased. Use a target
plate to increase the measurement range during daylight or if the target has poor reflection properties.
Target Surfaces
Measuring errors can occur when measuring toward colorless liquids (e.g. water) or dust free glass, Styrofoam or
similar semi-permeable surfaces. Aiming at high gloss surfaces may deflect the laser beam and lead to measurement
errors.
Against non-reflective and dark surfaces the measuring time may increase.
Care
Do not immerse the instrument in water. Wipe off dirt with a damp, soft cloth. Do not use aggressive cleaning
agents or solutions. Handle the instrument as you would a telescope or camera.
18
40
Page 19
.9 Labelling
www.tools.in.th
www.tools.in.th
Type:LDM-100by CEM
www.cem-meter.com.cn
Laser Distance Meter User Manual
19
Page 20
Laser Distance Meter User Manual
www.tools.in.th
www.tools.in.th
Rev.111125
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.