Please read this manual before switching the unit on.
Important
safety information inside.
Please read this manual before switching the unit on.
Important safety information inside.
User Manual
Laser Distance Meter
Laser-Distanzmesser
Laser distance-mètre
Metro di distanza laser
Medidor Láser de Distancia

Laser Distance Meter User Manual

.................................................4
..............................................................6
...................................9
.........................................................11
..........................................................12
....................................................15
......17
..........................................18
............................................................19
Safety Instruction
Start-Up
Initial Operation and Setting
Measuring
Functions
9
The compact and handy base model was specifically designed for indoor applications.
Shortcut and Soft grip keys for addition, subtraction, area and volume calculation make
measuring fast and very reliable.
1.
2.
3.
4.
5.
6.
7.
8.
.
Technical Data
Troubleshooting-Causes and Corrective Measures
Measuring Conditions
Labelling
Content
Laser Distance Meter User Manual
3

• Measuring distances
• Computing functions, e. g. areas and volumes
• Using the instrument without instruction
• Using outside the stated limits
• Deactivation of safety systems and removal of explanatory and hazard labels
• Opening of the equipment by using tools (screwdrivers, etc.), as far as not specifically permitted for certain cases
• Carrying out modification or conversion of the product
• Use of accessories from other manufacturers without the express approval of CEM Technology.
• Deliberate or irresponsible behavior on scaffolding, when using ladders, when measuring near machines which
are running, or near parts of machines or installations which are unprotected
• Aiming directly into the sun
• Inadequate safeguards at the surveying site (e.g. when measuring on roads, construction sites, etc.)
1.Safety Instruction
•
Permitted Use
Prohibited Use
Laser Distance Meter User Manual
4

Laser Classification
There is a visible laser beam which emerges from the front of the instrument.
Do not stare into the laser beam or direct it towards other people unnecessarily. Eye‘s protection is normally
afforded by aversion responses including the blink reflex.
Looking directly into the beam with optical aids (e.g. binoculars, telescopes) can be hazardous.
Do not look directly into the beam with optical aids.
Looking into the laser beam may be hazardous to the eyes.
Do not look into the laser beam. Make sure the laser is aimed above or below eye level.
Laser Class 2 products:
:
Precautions:
Precautions:
WARNING
CAUTION:
Laser Distance Meter User Manual
5

1) Remove battery compartment lid.
2) Insert batteries, observing correct polarity.
3) Close the battery compartment again.
Replace the batteries when the symbol “ “ flashes permanently
in the display.
• Use alkaline batteries only.
• Remove the batteries before any long period of non-use to avoid
the danger of corrosion
•
2 Start-Up.
•
Inserting/Replacing Batteries (See “Figure A”)
Figure A
Laser Distance Meter User Manual
6

Keypad (See “Figure B”)
1- button
2- button
3- button
4- Button
ON/MEAS
CLR/OFF
MEM/Reference
Function( )/Unit
Laser Distance Meter User Manual
7
OFF
MEM
Uint
Figure B
1
2
4
3

Laser Distance Meter User Manual
8
LCD Display (See “figure C”)
1- Laser active
2- Reference level (front)
3- Reference level (rear)
4- Battery status
5- Intermediate line 1
6- Intermediate line 2
7- Summary line
Figure C
1
2
3
4
5
6
7

Laser Distance Meter User Manual
9
Figure D
.3 Initial Operation and Setting
Switches on the instrument and laser.
Press this button longer to switch off the instrument.
The instrument switches off automatically after three minutes of inactivity.
The last action is cancelled or the data display is cleared. If in the
mode of History storage, press MEM button and Clear button simultaneously
will clear all storage data in the memory.
The default reference setting is from the rear of the
instrument. Long press this button to take the
selection from the front edge , A special beep
sounds whenever the reference setting is changed.
After a re-startup the reference returns automatically
to the default setting (rear reference).
Switching On and Off
Clear Button
Reference Level Setting (See “Figure D”)
OFF
MEM
Uint
OFF
MEM
Uint
OFF
OFF
MEM

Laser Distance Meter User Manual
10
Area
0.000 m²
0.000 ft²
0.000 ft²
0.000 ft²
0.000 ft²
1
2
3
4
5
Distance
0.000 m
0.0 in
0 1/16 in
0.000 ft
0’00” 1/ 61
Volume
0.000 m³
0.000 ft³
0.000 ft³
0.000 ft³
0.000 ft³
Click the button longer to change the next type of unit. The following unit can be set:
Distance Unit Setting For Instrument
Uint

Laser Distance Meter User Manual
11
Figure E
MIN
MAX
.4 Measuring
Press again to trigger the distance measurement. The measured value is displayed immediately.
The continuous measurement function (tracking) is used for the
transferring of measurements, e.g., from construction plans. In
continuous measurement mode, the measuring tool can be moved
to the target, whereby the measured value is updated approx.
Every 0.5 seconds in the third line. The corresponding minimum
and maximum values are displayed dynamically in the first and
second line.
As an example, the user can move from a wall to the required
distance, while the actual distance can be read continuously.
For continuous measurement, long press the button will
start the continuous measurement.
Press to activate the laser.
Single Distance Measurement
Continuous Measurement (Tracking) & Max and Min
Measurement (See “Figure E”)
OFF
Uint
MEM
OFF
Uint
MEM

Laser Distance Meter User Manual
12
.5 Functions
Press the button once will start the area measurement function.
Press button to take the first length measurement (e.g. length).
Press again to take the second length measurement (e.g. width).
The result of the area measurement is displayed in the third line, the individually measured values are displayed in
lines 1 and 2.
Area Measurement
And press or button
again to stop the function. The function is terminated automatically
after continuous 100 times measurement.
The MIN and MAX data will display in lines 1 and 2 individually.
OFF
Uint

Laser Distance Meter User Manual
13
Whilst the first connection between the Phone/PC and the Laser distance meter is being established, a prompt for
the Pin-code of the instrument may be displayed. In this case, enter the code 0000 into your Phone/PC.
Press and hold Func/Unit button until the Bluetooth symbol disappears in the display.
The BLUETOOTH switches off as soon as the instrument is switched off.
Switching off BLUETOOTH
Volume Measurement
Push button twice will start volume measurement function .
press to takes first distance measurement (e.g. Length)
press to takes second distance measurement(e.g. width)
The result of the area measurement from the values already measured is displayed in the summary line.
Press to takes the third distance measurement(e.g. height). The value is displayed in the second line.
The result of the volume measurement is displayed in the summary line, the two previously measured values in lines
1 and 2.
Unit
Uint

Laser Distance Meter User Manual
14
Historical Storage
Bluetooth function (Optional)
The previous 20 records (measurements or calculated results) are shown in the reverse order. Use buttons
to navigate through these records.
You can clear all records by press Storage button and Clear button simultaneously in historical storage mode.
Press and hold Func/Unit button until the Bluetooth symbol appears in the display. Then you can use our Meterbox
APP installed on your phone to connect with this instrument.
Switching on BLUETOOTH / sending measurements
MEM

Laser Distance Meter User Manual
15
6.Technical Data
Technical Specifications
Range (use target plate from about 50m)
Measuring accuracy up to 10m
(2 , standard deviation)
Measuring units
Laser Class
Laser Type
Smallest unit displayed
Area, Volume Calculations
Continuous Measurement
Min/Max Distance Tracking
Display illumination and multi-line display
Beep indication
BLUETOOTH® 4.0 EDR
Range of BLUETOOTH®
BLUETOOTH® with Apple iPod/iPhone support
BLUETOOTH® with SPP support
σ
0.05 to 30 m*(0.2 in to 98 ft*)
Typically: ±1.5 mm**
(± 1/16 in**)
m,in,ft
Class II
650 nm, <1mW
1mm
10m
√
√
√
√
√
√
√
O

Laser Distance Meter User Manual
16
* Use a target plate to increase the measurement range during daylight or if the target has poor reflection properties!
** in favourable conditions (good target surface properties, room temperature) up to 10 m (33 ft). In unfavourable
conditions, such as intense sunshine, poorly reflecting target surface or high temperature variations, the deviation
over distances above 10 m (33 ft) can increase by ± 0.15 mm/m (± 0.0018 in/ft).
Dust Protect/Splash proof
History measurement records
Keyboard Type
Operating Temperature
Storage Temperature
Batteries
Battery Life
Auto laser switch-off
Auto instrument switch-off
Dimension
Weight
IP 54
20
Super Soft-Touch (Long life)
0° C to 40° C(32° F to 104° F)
-10° C to 60° C(14° F to 140° F)
Type AAA 2 x 1.5V
up to 5,000 measurements
after 30 seconds
after 3 min
135x33x24mm
80g

Laser Distance Meter User Manual
17
7.Troubleshooting – Causes and Corrective Measures
Code
208
252
253
255
Cause
Received signal too weak,
measurement time too long.
Distance >50m
Temperature too high
Temperature too low
Hardware error
Corrective measure
Use target plate
Cool down instrument
Warm up instrument
Switch on/off the device several times,
If the symbol still appears, please contact
your dealer for assistance.

Laser Distance Meter User Manual
18
8.Measuring Sonditions
The range is limited to 30m.
At night or dusk and if the target is in shadow the measuring range without target plate is increased. Use a target
plate to increase the measurement range during daylight or if the target has poor reflection properties.
Measuring errors can occur when measuring toward colorless liquids (e.g. water) or dust free glass, Styrofoam
or similar semi-permeable surfaces. Aiming at high gloss surfaces may deflect the laser beam and lead to
measurement errors.
Against non-reflective and dark surfaces the measuring time may increase.
Do not immerse the instrument in water. Wipe off dirt with a damp, soft cloth. Do not use aggressive cleaning
agents or solutions. Handle the instrument as you would a telescope or camera.
Measuring Range
Target Surfaces
Care

Laser Distance Meter User Manual
19
.9 Labelling

Rev.150205
Laser Distance Meter User Manual