DT-8806 H is a professional human body temperature measurement forehead contactless infrared thermometer measurement, it has been revealed that people scientific name infrared thermometer or contactless infrared forehead thermometers.
product characteristics 】
1. Non-contact measurement, effectively reduce the bacteria cross infection
2. The body and the body with two measurement mode: Body: special measuring the body temperature The body: can be used to measure the environment, the object surface temperature
3. Fast measure, response time of just 0.5 seconds
4. Has the memory function, can be stored 32 measuring values
5. Can be set alarm functions, higher than the alarm value, buzzer automatic 6, invisible infrared measurement.
The technical indexes 】
It has been revealed people temperature range: 30.0-43 / 86-109 The surface temperature measuring range: 0-60 / 32 ℉-140 ℉ Basic precision: people it has been revealed under the mode of temperature + 0.4 / + 0.7 The surface temperature measurement mode + 0.8 / + 1.5 Distance is measured: 1-15 centimeters
Response time: 0.5 seconds Super range tip: screen will show "HI" / "Lo" Emission rate: fixed for 0.95 Spectrum response: 6-14 um Automatic power: about seven seconds after the automatic shutdown Operating temperature: 0 ℃-50 ℃ 32 ℉-122 ℉
Storage temperature:-20 ℃-60 ℃ (140 ℉-4-℉) Relative humidity: 10% 90% RH operation, < 80% RH storage Power supply: 2 section 5, AA battery
The operating instructions
1. The body temperature measurement to the body when dial mode; Measuring surface temperature dial the to those mode.
2. The temperature will be pointing a gun at the forehead heart, a distance of about 1 to 15 CM, ensure no hair, sweat, and keep out of the hat, etc.
3. Dig dynamic measurement trigger buttons, hear "di" of a loud buzz, measuring over.
The warm prompt 】
The human body each place, every morning and the temperature between men and women are the difference, in view of the different body this product specially set up a school function when add and subtract. The products had been through strict and scientific sterile constant temperature in the room of the adjustments. The first time users in order to make the measurement data comply with the use of personal habits can also use mercury thermometer for DT-8806 H to reset. (1) for measuring low temperature (see chart of different age stages in the temperature range), and mercury thermometer how much time will accordingly how much can be complete correction and, like silver thermometer monitoring to someone (20) temperature is 37.5 , and DT-8806 H measure for 37 , then
according to the following steps by 0.5 ℃. (2) high temperature measurement section (higher than the corresponding age when the highest temperature), it is required to use correction by 0.7 can.
The operating instructions
1. The body temperature measurement to the body when dial mode; Measuring surface temperature dial the to those mode.
2. The temperature will be pointing a gun at the forehead heart, a distance of about 1 to 15 CM, ensure no hair, sweat, and keep out of the hat, etc.
3. Dig dynamic measurement trigger buttons, hear "di" of a loud buzz, measuring over.
The warm prompt 】
The human body each place, every morning and the temperature between men and women are the difference, in view of the different body this product specially set up a school function when add and subtract. The products had been through strict and scientific sterile constant temperature in the room of the adjustments. The first time users in order to make the measurement data comply with the use of personal habits can also use mercury thermometer for DT-8806 H to reset. (1) for measuring low temperature (see chart of different age stages in the temperature range), and mercury thermometer how much time will accordingly how much can be complete correction and, like silver thermometer monitoring to someone (20) temperature is 37.5 , and DT-8806 H measure for 37 , then
according to the following steps by 0.5 ℃. (2) high temperature measurement section (higher than the corresponding age when the highest temperature), it is required to use correction by 0.7 can.
The human body has a normal body temperature of the more stable range, but not constant, pictured above all phases of a lifetime of temperature difference
correction step 】
1. DT-8806 H dial the to the body mode.
2. After about two seconds MODE key, LCD display F1, then loose open MODE key, again even according to 2 times MODE key appears 0.0.
3. Will be transferred to the 0.0 0.7, through adjusting the key.
4. Once again even press MODE key until exit regulation MODE.
The application 】
1. The family to use DT-8806 H cannot disturb sleep in children or to see the child play the temperature changes every day, about children's health. The body pattern can measure the temperature of the infant and bottle of temperature, convenient rushed to mix the milk powder. Pregnant women, old people use this product also greatly enhancing the convenience. Family is to prevent and rapid screening daily disease detection and health condition of the close good helper!
2. The airport, car, customs and other public places In the airport, station, customs, etc for the passenger flow dense place individuals measuring temperature. For international return flight passengers temperature will become a "screening fever patient" of the first a pass.
3. Schools, enterprises and institutions, etc During the college entrance examination shall be equipped with my school doctor and each staff the