OPERATING INSTRUCTION
1000A True RMS DC/AC CLAMP METER

Safety
International Safety Symbols
This symbol, adjacent to another symbol or
terminal, indicates the user must refer to the
manual for further information.
This symbol, adjacent to a terminal, indicates that,
under normal use, hazardous voltages may be
present
Double insulation
SAFETY NOTES
Do not exceed the maximum allowable input range of
any function
Do not apply voltage to meter when resistance function
is selected.
Set the function switch OFF when the meter is not in
use.
WARNINGS
Set function switch to the appropriate position before
measuring.
When measuring volts do not switch to
current/resistance modes.
When changing ranges using the selector switch always
disconnect the test leads from the circuit under test.
Do not exceed the maximum rated input limits.
CAUTIONS
Improper use of this meter can cause damage, shock, injury
or death. Read and understand this user manual before

operating the meter.
Always remove the test leads before replacing the battery.
Inspect the condition of the test leads and the meter itself for
any damage before operating the meter. Repair or replace
any damage before use.
Use great care when making measurements if the voltages
are greater than 25VAC rms or 35VDC. These voltages are
considered a shock hazard.
Remove the battery if the meter is to be stored for long
periods.
Always discharge capacitors and remove power from the
device under test before performing Diode, Resistance or
Continuity tests.
Voltage checks on electrical outlets can be difficult and
misleading because of the uncertainty of connection to the
recessed electrical contacts. Other means should be used
to ensure that the terminals are not "live".
If the equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment may
be impaired.
Resistance, Diode, Continuity,
Capacitance, Frequency, Duty
Cycle, Test

7
8
5
6
3
4
A
AC
mV
kM
DC
¡ã¡ãF
C
Hz%
9
2
1
A
400A
40A
Meter Description
1. Current clamp
2. Clamp trigger
3. Data Hold and Backlight button
4. Mode select button
5. Hz/% button
6. LCD display
7. COM input jack
8. Rotary Function swith
9. ZERO button
10. Range select button
11. V Ω ℃/℉ jack
12. Battery compartment on rear
1. AC DC AC (alternating current)
and DC (direct currrent)
2. Minus sign
3. 8.8.8.8 4000 count (0 to 3999)
measurement reading
4. AUTO AutoRange mode
5. Diode test mode
6. •))) Audible Continuity
7. HOLD Data Hold mode
9.℃,℉, ,m,V,A,K,M,Ω , Units of measure list