CellarCool ACH 550 Owner's Manual

Page 1
TECH/OWNERS MANUAL
ACH 033114
Page 2
Copyright © 2012. CellarCool. All rights reserved.
This manual, the product design, and the design concepts are copyrighted by CellarCool, with all rights reserved. Your rights with regard to the hardware and manual are subject to the restrictions and limitations imposed by the copyright laws of the United States of America. Under copyright laws, this manual may not be copied, reproduced, translated, transmitted, or reduced to any printed or electronic medium or to any machine-readable form, for any purpose, in whole or in part, without the written consent of CellarCool.
Every eort has been made to ensure that the information in this manual is accurate. CellarCool is not responsible for printing or clerical errors.
CellarCool reserves the right to make corrections or improvements to the information provided and to the related hardware at any time, without notice.
Vinothèque and CellarCool are registered trademarks, and ECE is a trademark of CellarCool. All rights reserved.
Mention of third-party products is for informational purposes only and constitutes neither an endorsement nor a recommendation. CellarCool assumes no liability with regard to the performance or use of these products.
03.31.14
ACH 033114
Page 3
TABLE OF CONTENTS
Quick Reference Guide
System ..................................................
Specications ............................................
2 3
Introduction ................................................
Receiving & Inspecting The System .........................
Before You Start ............................................
Unobstructed Airow .......................................
Active Humidity Option Overview ..........................
Installing the ACH 550 Humidier ..........................
Humidistat Installation .....................................
Installing the ACH 550 Humidier Continued ..............
Installing the Drain Line ....................................
Maintenance Schedule .....................................
Troubleshooting Guide .....................................
Technical Assistance & Accessories .........................
Installation Terms and Conditions ..........................
4
5
6
7
8
9
10
12
13
14
15
16
17
www.cellarcool.com | Page 1
Page 4
Wall Mounted ACH 550 Humidier Front / Side View
Top Access Panel
QUICK REFERENCE GUIDE
Power Cord
Humidistat
Connection
Water Port
Drain Line
Connection
Mounting Key Holes
Humidier Rear / Side View
Page 2 | 1-855-235-5271
ACH 033114
Page 5
ACH 550 SPECIFICATIONS
Model ACH 550
Dimensions 14 7/16”w x 7 1/8”d x 8 3/16”h
Power Consumption 0.2 amps @ 120V/60 Hz
Weight (lbs) 9
dBA TBD
Drainline 1/2”
Humidistat Range
Humidistat Accuracy
Humidistat Adjustment Increments
Water Supply Feed Rate
Humidistat Digital Control Display
Warranty 2 year parts and labor
30-90% RH
± 1%
1%
0.63 gph @ 40 psi
www.cellarcool.com | Page 3
Page 6
INTRODUCTION
Customer Service
Thank you for purchasing a CellarCool humidifying system. We strive to provide the highest quality products and the best possible customer service. If you have any questions about your system, please call us at 1-855-235-5271 or visit CellarCool.com.
Using the Manual
This Owners Manual is intended to assist in the proper installation maintenance of the system. In order to ensure the longevity of your humidier, the equipment should be installed as outlined in the Owner’s Manual. It is also vital to establish a proper care and maintenance schedule. Please read and review this manual carefully and keep it for future reference.
Mail to: CellarCool ATTN: Warranty Registration 1738 E. Alpine Avenue Stockton, CA 95205-2505 USA
Page 4 | 1-855-235-5271
Fax to:
209.466.4606
OR OR
Scan and email to:
ACH 033114
Page 7
RECEIVING & INSPECTING THE SYSTEM
Receiving and Inspecting the System
• Lift only at the designated hand hold locations on the shipping container or fully support the unit from
underneath. A shipment may include one or more boxes containing accessories.
• Before opening the container, inspect the packaging for any obvious signs of damage or mishandling.
• Write any discrepancy or visual damage on the Bill of Lading before signing.
Note: CellarCool units are manufactured in the USA and tested prior to shipment.
Review the Packing Slip to Verify Contents
• Check the model number to ensure it is correct.
• Check that all factory options ordered are listed.
If any items listed on the packing slip do not match your order information,
contact CellarCool Customer Service immediately.
Check the Box for the following contents:
Main Humidier Box
(4) 2” #8 Hex Head Screws (1) 10 FT. 1/2”Drain Line (1) ACH 550 Owner’s Manual (1) Humidistat w/25’ of Cable (1) 90° Barb Fitting
(1) ACH 550 Humidier
Please leave the unit in its original box until you are ready for installation. This will allow you to move the product safely without damaging it. When you are ready to remove the product from the box, refer to the installation instructions.
TIP: Save your box and all packaging materials. They provide the only safe means of transporting/shipping the unit.
www.cellarcool.com | Page 5
Page 8
BEFORE YOU START
1. Inspect all components prior to installation. If damage is found, please contact your distributor or CellarCool Customer Service at 1-855-235-5271.
2. It is REQUIRED to install a drain line to remove condensation from the Humidifier.
3. The system is intended for use in properly designed and constructed controlled rooms. Hire a professional consultant with a valid contractor’s license to build your controlled room that is well insulated.
If you encounter a problem with your CellarCool unit, please refer to the Troubleshooting Guide on page 15. If you have any further questions, concerns, or need assistance, please contact CellarCool’s Customer Service at
5271. Please be sure all testing has been completed prior to contacting Customer Service. Please have your results
ready for your representative.
1-855-235-
Page 6 | 1-855-235-5271
ACH 033114
Page 9
Unobstructed Airow
Unobstructed airflow to and from the system is critical for the Humidifier’s overall performance and life-span. A
minimum three-foot clearance (five foot is ideal) area is crucial.
Note: Avoid attempting to camouflage the unit. This will restrict airflow and thus the systems’s ability to work efficiently.
Mounting the Humidier
The Humidier must be mounted at least 3’ from the oor in order to achieve sucient humidity. Mounting the unit high in the room will contribute to a consistently humid environment.
Door and Door Seal
An exterior grade (1 3/4”) door must be installed as a cellar door. It is essential that weather stripping is attached to all 4 sides of the doorjamb. A bottom “sweep” or threshold is also required. The door must have a very good vapor seal to prevent the moisture in the cellar from escaping. One of the most common problems with a humidifier running continually is due to the door not sealing properly.
www.cellarcool.com | Page 7
Page 10
ACTIVE HUMIDITY OPTION OVERVIEW
Use of the Active Humidity Option
Humidity may uctuate in the controlled room. The Active Humidity Option stabilizes the environment by adding moisture when the relative humidity in the controlled room is becoming low. Using a humidistat and a water source, the Active Humidity Option is able to regulate and establish a humid environment suitable for wine storage.
Note: The target humidity for most controlled rooms is between 50-70%.
General Active Humidity Option Recommendations
• Water source needs to have at least 40 psi.
• Water tubbing size: 1/4” O.D
• Water source should be tested for content and characteristics.
• In areas that are known to have hard water, the use of a Water-Softener System is required.
Note: Failure to install a Water-Softener or a Filtration system will allow an
excessive particle residue buildup and may lead to system failure.
• Even if the area is not known to have hard water, the use of a Filtration System (Particle Filter) is required.
• Use a Self-Piercing Saddle Valve as a simple connection to a water source.
• Clean or replace the Misting Nozzle every 12 months.
MISTING NOZZLE
Page 8 | 1-855-235-5271
ACH 033114
Page 11
INSTALLING THE ACH 550 HUMIDIFIER
Note: The Humidier is designed to be mounted with Drywall Anchors.
Note: The bottom of the unit needs to be installed no less
than 3 feet from the oor.
1. Mark the location in which the two screws will be installed. Make sure the screws are installed level on the wall.
1/8”
2. Install the supplied two 2” #8 Hex Head Screws into the marked
WALL
mounting screw locations leaving 1/8” between the wall surface and screw head.
3. Remove the top access panel.
4. Raise the Humidier to the installation location, align the rear key holes with the mounting screws and mount the unit.
5. Use a 1/4” wrench or socket to tighten the accessible mounting screws.
6. Reinstall the top access panel.
www.cellarcool.com | Page 9
Page 12
HUMIDISTAT INSTALLATION
Note: Only a 120v Humidistat can be used with this unit.
Routing the Wiring
1. Plug the circular connector from the humidistat cable into the circular connector on the unit as shown in
Figure 1.
2. Route the wire from the unit to the desired humidistat location.
Figure 1
Removing the Cover
1. Move both slide controls to the bottom position.
2. Use a screwdriver to loosen the screws at the bottom of the humidistat as shown in Figure 2.
Slide controls
to the bottom
position
Figure 3
3. Carefully remove the cover as shown in gure Figure 3.
Figure 2
Mounting Without a Wall Mount Plate
1. Make sure the humidistat electrical is unplugged before installing the unit.
2. Position the back half of the humidistat cabinet on the wall or junction box and ensure it is level and covers the
junction box completely.
3. Pull the electrical wires through the hole at the terminal block of the humidistat.
4. Drill holes in the wall through the 2 mounting holes in the back of the humidistat cabinet as shown in Figure 4
and insert anchors into the holes.
5. Fasten the humidistat to the wall with screws through the mounting holes.
Screws
Page 10 | 1-855-235-5271
Figure 4
Terminal Block
ACH 033114
Page 13
HUMIDISTAT INSTALLATION
Mounting With a Wall Mount Plate
1. Make sure the humidistat is unplugged before installing the unit.
2. Position the wall mount plate on the wall or junction box and
ensure the plate is level and covers the junction box completely.
3. Pull the electrical wires through the hole in the wall mount plate.
4. Drill holes in the wall through the 2 mounting holes in the back of
the wall plate as shown in Figure 5 and insert anchors into the holes.
5. Pull the electrical wires through the hole at the terminal block.
6. Fasten the wall plate with 2 screws through the mounting holes.
7. Then fasten the humidistat to the wall plate with screws through the
mounting holes.
Electrical Connection
1. Connect the electrical wires to the corresponding terminals on the
terminal block following the circuit diagram inside the top cover of the unit. See Figure 6
2. Connect the white wire to the N terminal, the red wire to the 1
terminal, and the black wire to the L terminal on the humidistat.
Humidistat Rubber Buttons
Wall Anchors
Figure 5
HUMIDISTAT
L 12 34N
RED
BLACK
WHITE
Figure 7 - Make sure the Dial is Vertical and the
Adjustment Shaft is Horizontal
NOTE: If the controls are not lined up when the faceplate is being reattached,
then the controls may become stuck. In order to reattach the faceplate correctly
5. Attach the screws again at the bottom of the cover and tighten into place as
6. Check that the adjustment dial and slide controls can be moved smoothly,
Correct Humidistat Settings
1. Rotate the dial to the desired humidity level.
2. Set the bottom selector switch to the Humid setting.
Figure 8
3. Set the top selector switch to the Hi setting.
Figure 6
COOLING UNIT
Reattaching the Cover
1. Move both slide controls to the bottom position.
2. Align the humidistat adjustment shaft horizontally as
shown in Figure 7.
3. In order for the humidistat dial to t on the shaft, it must
be aligned with the pointer above the dial.
4. Carefully attach the top cover and ensure the cover locks
into place by pushing down on the top and then pushing inward toward the wall.
move the slide controls to the bottom position to line up them up.
shown in Figure 8.
otherwise remove the cover and check the alignment of the dial, the adjustment shaft and the slide controls.
www.cellarcool.com | Page 11
Page 14
INSTALLING THE ACH 550 HUMIDIFIER CONTINUED
TUBING OUTLET
Self-Piercing Saddle Valve
Install a Self-Piercing Saddle Valve to a near by water supply for simple connection to a water source as shown in Figure 9.
Figure 9
Water Flow Order
• The water supply should pass through either a Water-Softener or a Filtration system before reaching the unit as
shown in Figure 10.
• Route a 1/4” Copper, Pex or equivalent tubing from the water source and connect to the water inlet tting on the
unit as shown in Figure 11.
• Turn on the water and check for leaks.
HUMIDIFIER
OPTIONAL INSERT FOR
PLASTIC TUBING
WATER SUPPLY
Figure 11
FILTRATION SYSTEM
Figure 10
Page 12 | 1-855-235-5271
ACH 033114
Page 15
INSTALLING THE DRAIN LINE
Drain Line
The drain line tube is used to remove excess water from the humidier to a proper discharge location. It is important that the drain line tube is properly connected and used to prevent leakage and other problems associated with excess water. It is mandatory to install the drain line whether it leads through the wall and out of the controlled space.
Failure to use the condensation drain line tube will void the warranty on the unit.
Use the barbed elbow as shown in Figure 12 to route the water to the discharge location below.
Barbed Elbow
Figure 12
WRONG: Drain line is under water.
Failure to install the drain line voids the warranty.
To prevent mold from growing, allow the drain line to hang above the water line.
NOTE: Using the barbed elbow as shown
in Figure 12 is recommended.
www.cellarcool.com | Page 13
Page 16
MAINTENANCE SCHEDULE
Monthly 1. Check for unusual noise or vibration
2. Check the drain line to see if it is above the waterline if draining into a vessel.
Quarterly
Annually
2. Clean the Humidier Fan compressed air.
1. Inspect for corrosion.
2. Check wiring connections and integrity of cords.
3. Pour a 50/50 bleach solution into the drain line every spring.
Page 14 | 1-855-235-5271
ACH 033114
Page 17
TROUBLESHOOTING GUIDE
Unit does not run/power up
Possible Cause Solution
Humidier is not plugged in Make sure the unit is plugged into an outlet
Power switch not on Turn unit on by pressing the power button on the control
Line voltage is incorrect rating for the system Check line voltage to make sure there is 110v/120v
Room at set point Lower set point
Humidistat not calling for humidifying Lower set point
Faulty Humidistat or wiring Call Customer Service at 1-855-235-5271
Humidity Levels are too Low
Possible Cause Solution
There is something blocking the supply and/or return air, on the Humidier.
Humidier is mounted too low in the cellar Re-Locate unit so the distance from the ceiling and top of
One or more of the fans are not turning on. Please contact the installing technician to troubleshoot.
Compressor is not turning on. Please contact the installing technician to troubleshoot.
Compressor keeps cycling on overload Make sure all fans are working and there are no airow
Poor seal around door or other areas requiring a seal (around the unit, wall joints, etc)
Controller set too high Lower the set point.
Remove air ow obstruction
the unit is no more than 18”
obstruction.
Make sure there are no air gaps around the door. If door seal is damaged, replace it.
System Runs Constantly
Possible Cause Solution
Leaky door seal or poorly insulated cellar. Fix leaky door seal and insulate cellar in accordance with
this manual. (Page 9)
Unit leaks water
Possible Cause Solution
Humidier is not level
Drain line clogged or kinked Check drain line to make sure water can ow freely.
Drain is clogged preventing water form escaping
Drain line does not have a downward slope
Unit runs but does not Humidify
Possible Cause Solution
Lack of air ow
Misting Nozzle not working properly Contact Customer Service at 1-855-235-5271
Humidier should be level on the wall to prevent leaking.
Disconnect drain and clear out, open access door and check drain for blockage
Fix Drain line so there is a downward slope from the unit to the drain.
Make sure fan is unobstructed.
www.cellarcool.com | Page 15
Page 18
TECHNICAL ASSISTANCE
CellarCool Customer Service is available Monday through Friday from 8:00 a.m. to 4:00 p.m. Pacic Time.
The customer service representative will be able to assist you with your questions and warranty information more eectively if you provide them with the following:
• The model and serial number of your CellarCool systems.
• Location of unit and installation details, such as ventilation, ducting, construction of your wine cellar, and
room size. Photos of the cellar and installation location may be needed.
Contact CellarCool Customer Service
1738 E. Alpine Ave Stockton, CA 95205 www.CellarCool.com Email: [email protected] Phone: (209) 466-9463 US Toll Free 1(855) 235-5271 Fax (209) 466-4606
ACCESSORIES FOR COOLING UNITS
Accessories can be purchased at www.cellarcool.com
Page 16 | 1-855-235-5271
ACH 033114
Page 19
ACH 550 Product
Warranty Information
CellarCool Product Terms and Conditions
Including Product Limited Warranty And Product Installation Requirements
For CellarCool Extreme Series
ATTENTION: PLEASE READ THESE TERMS OF USE CAREFULLY BEFORE INSTALLING YOUR CELLARCOOL COOLING SYSTEM. INSTALLING YOUR CELLARCOOL COOLING SYSTEM INDICATES THAT YOU ACCEPT AND AGREE TO EACH OF THE TERMS AND CONDITIONS SET FORTH HEREIN (“TERMS OF USE”). IF YOU DO NOT ACCEPT THESE TERMS OF USE, YOU RISK VOIDING YOUR WARRANTY AND ASSUMING ADDITIONAL REPAIR AND REPLACEMENT COSTS.
1. Purchase of a CellarCool Cooling System assumes that the Purchaser (“End User”) fully accepts and agrees to the Terms and Conditions set forth in this document. The Terms and Conditions of Sale and Owner’s Manual are shipped with each unit and, if another copy is needed, replacement copies can be downloaded from the company website (cellarcool.com) or by contacting CellarCool directly for a new copy. CellarCool reserves the right, in its sole discretion, to change its Terms and Conditions at any time, for any reason, without notice.
2. CellarCool Product Limited Warranty:
A. Two (2) Year Limited Warranty. For the period of TWO (2) YEARS (the “Limited Warranty Period”) from the date of
original sale of a Product by CellarCool, if a CellarCool Product is found to be defective in material or workmanship after undergoing CellarCool’s customer service troubleshooting, then, subject to the CellarCool Product Limited Warranty Limitations and Exclusions as well as the other Terms and Conditions stated herein, CellarCool will do the following, as appropriate, for the end user (“End User”) who has installed and is actually using the Product, with regard to LABOR, PARTS and FREIGHT:
1. LABOR - repair or replace (at CellarCool’s sole option) the Product. If CellarCool determines that Product is to be REPLACED, there will be no labor reimbursement. If CellarCool chooses to REPAIR the Product, CellarCool will consider possibility of maximum reimbursement of $350.00 in labor for REPAIRING Product on site and supplying all parts at no charge. Invoice for service must be forwarded to CellarCool for assessment and processing.
2. PARTS – supply, at no charge, new or rebuilt replacement parts for the Product in exchange for the return of defective parts. CellarCool, at its option, will assess possibility to replace unit that is at the original site with a warranty replacement unit OR consider possibility of supplying all parts at no charge.
3. FREIGHT – cover normal ground freight charges for parts, and, in the event the Product is not repairable in the eld, CellarCool, at its option, will pay freight charges to return original Product to CellarCool for evaluation. End User is responsible for freight charges of replacement Product being shipped to End User.
B. Five (5) Year Compressor Limited Warranty. CellarCool Product’s compressor only will be covered for ve (5) years
from date of purchase. Labor and freight of compressor is the End Users responsibility.
C. Product Warranty Limitations and Exclusions:
1. This limited warranty does not cover cosmetic damage caused during installation, damage due to acts of God, commercial use, accident, misuse, abuse, negligence, or modication to any part of the Product. Delivery and installation of the Product, any additional parts required, as well as removal of the Product if warranty work is required, are all at the sole cost, risk and obligation of the End User.
2. This limited warranty does not cover damage due to improper installation or operation or lack of proper maintenance of the Product, connection of the Product to improper voltage supply, or attempted repair of the Product by anyone other than a technician approved by CellarCool to service the Product.
3. This limited warranty does not cover any Product sold “AS IS” or “WITH ALL FAULTS.”
4. Product that has been replaced during warranty period does not extend the warranty period past the original date of purchase.
5. This limited warranty is valid only in the continental United States. Sales elsewhere are excluded from this
www.cellarcool.com | Page 17
Page 20
1. warranty.
2. Proof of purchase of the Product in the form of a bill of sale, receipted invoice or serial number, which is evidence that the Product is within the Limited Warranty Period, must be presented by the End User to CellarCool in order to obtain limited warranty service.
3. This limited warranty is void if the factory applied serial number has been altered or removed from the Product.
4. This limited warranty is voided if installed in an enclosure of insucient design that does not follow the Product installation requirements stated herein and in the owner’s manual.
5. Removing the rivets from the Product’s unit housing without prior authorization from CellarCool voids this limited warranty.
6. The End User must rst contact CellarCool Customer Service by telephone (at 1-800-343-9463) prior to attempting service on any Product still under the limited warranty; else the limited warranty is voided.
7. This limited warranty does not cover Product being concealed by, but not limited to, vegetation, fabric, shelving, mud, snow, or dirt. Product must not be painted or limited warranty will be void.
8. This limited warranty does not cover exposure to corroding environments such as, but not limited to, petroleum and gasoline products, cleaning solvents, caustic pool chemicals, and marine air.
9. This limited warranty does not cover any cause not relating to Product defect.
10. THE REPAIR OR REPLACEMENT OF THE PRODUCT AS PROVIDED UNDER THIS LIMITED WARRANTY IS THE EXCLUSIVE REMEDY OF YOU, THE END USER, AS WELL AS ANYONE ELSE IN THE CHAIN OF TITLE OF THE PRODUCT, DOES NOT START A NEW LIMITED WARRANTY TIME PERIOD, AND IS IN LIEU OF ALL OTHER WARRANTIES (EXPRESS OR IMPLIED) WITH REGARD TO THE PRODUCT. IN NO EVENT SHALL CellarCool BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, SPECIAL OR CONTINGENT DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT. THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY EXPRESSLY DISCLAIMED. Some states do not allow the exclusion or limitation of incidental or consequential damages, or allow limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This limited warranty gives you specic legal rights, and you may have other rights, which vary from state to state.
11. Failure of the End User to comply with all of the Product Installation Requirements, Maintenance Requirements and End User Requirements may, at CellarCool’s sole discretion, void this limited warranty.
12. No one has any authority to add to or vary the limited warranty on this Product.
3. Product Installation Requirements:
A. Prior to installing a CellarCool Product, the End User must read the CellarCool Owner’s Manual and thereafter
the End User must follow the required installation, use and maintenance procedures set forth by CellarCool in CellarCool’s Owner’s Manual. The Owner’s Manual is shipped with each Product and if another copy is needed, replacement copies can be downloaded from CellarCool’s website (www.cellarcool.com) or by contacting
CellarCool directly for a new copy of the Owner’s Manual. B. It is highly recommended that the End User obtain the assistance of a wine storage professional. C. Failing to address all of the variables associated with proper installation will cause the Product to operate
incorrectly and limit both the Product’s ability to cool and the longevity of the Product itself. D. The End User is responsible for all risks and costs of installation of the Product, including but not limited to
all labor costs as well as cost of any additional parts required for the proper and complete installation of the
Product. The End User is responsible for all risks and costs of removing the Product if limited warranty work is
required. E. The Product cannot operate at its optimum capacity if airow is constricted by ducting or venting the exhaust
side of the Product into a location with inadequate ventilation.
4. Maintenance Requirements
It is the End User’s responsibility to clean o any accumulated dust, lint, or other debris from the front and rear intake grills; failure to do this on a regular basis will restrict the airow and may aect the Product’s ability to
Page 18 | 1-855-235-5271
ACH 033114
Page 21
function properly. Periodically cleaning the Product’s vents will help assure maximum cooling eciency. The drain tube must also be checked and kept clean and free of debris and mold to maintain proper performance.
Mold is a natural living organism in the environment. It exists in the air in the form of microscopic spores that move in and out of buildings through doors, windows, vents, HVAC systems and anywhere else that air enters. Once it is discovered, mold must be addressed quickly and appropriately. Delayed or improper treatment of mold issues can result in costly and reoccurring repairs. If the End User suspects a mold problem, it is always best to hire a qualied and experienced mold remediation specialist.
5. Additional End User Costs And Responsibilities
The following items are not covered under any warranty and are the sole responsibility of the End User: A. End Users should satisfy themselves that the Product they are purchasing is suitable for their particular needs
and requirements, and thus no responsibility will be placed with CellarCool for the End User’s decisions in this regard.
B. It is the End User’s responsibility to secure safe haven/storage for ANY AND ALL items that are being kept and
stored in the End User’s wine cellar, including any Product. CellarCool takes no responsibility for the safety and preservation of the aforementioned items in the event that the environment becomes unsuitable to maintain a proper storage environment.
C. End User is responsible for initial installation costs, including, but not limited to, labor costs and the cost of any
additional parts necessary to complete the installation.
D. End User is responsible for all costs incurred for the installation and/or removal of the Product, or any part
thereof, unless such cost has been agreed by CellarCool to be a warranty repair prior to the work being performed.
6. Sales and Use Tax
CellarCool only collects California sales tax for orders shipped within the State of California; CellarCool does not collect sales tax for orders shipped to other states. However, the Purchaser and the End User may be liable to the taxing authority in their state for sales tax and/or use tax on the Product. The Purchaser and the End User should each check with their state’s taxing authority for sales and use tax regulations.
7. Customer Service and Troubleshooting
CellarCool’s customer service department is available to answer any questions or inquiries for End Users regarding a CellarCool Product, as well as to assist in performing basic troubleshooting, Monday through Friday, from 6:30 a.m. to 4:00 p.m. PST, at telephone number 1-800-343-9463. CellarCool Corporation is located at 1738 East Alpine Avenue, Stockton, California 95205.
8. Miscellaneous Terms and Conditions
A. Return Policy. All return inquiries must be made within thirty (30) calendar days of the original purchase of a
Product and are subject to a twenty ve percent (25%) restocking fee. Shipping costs are not refundable and the
Purchaser is responsible for all return shipping costs (including customs fees and duties, if applicable). B. Security Interest. CellarCool retains a security interest in each Product until payment in full. C. Construction and Severability. Every provision of these Terms and Conditions shall be construed, to the extent
possible, so as to be valid and enforceable. If any provision of these Terms and Conditions is held by a court of
competent jurisdiction to be invalid, illegal or otherwise unenforceable, such provision will, to the extent so held,
be deemed severed from the contract of sale between Purchaser and CellarCool, and all of the other non-severed
provisions will remain in full force and eect. D. Governing Law/Choice of Forum. The laws of the State of California (without regard for conicts of law) shall
govern the construction and enforcement of the these Terms and Conditions of Sale (Sections 1 through 9
inclusive, including Product Limited Warranty And Product Installation Requirements), and further these Terms
and Conditions of Sale shall be interpreted as though drafted jointly by CellarCool and Purchaser. Any dispute
will be resolved by the courts in and for the County of San Joaquin, State of California, and all parties, CellarCool,
Purchaser and End User, hereby irrevocably submit to the personal jurisdiction of such courts for that purpose.
www.cellarcool.com | Page 19
Page 22
No waiver by CellarCool of any breach or default of the contract of sale (including these Terms and Conditions of
Sale) concerning a Product will be deemed to be a waiver of any preceding or subsequent breach or default.
E. Correction of Errors and Inaccuracies. These Terms and Conditions may contain typographical errors or other
errors or inaccuracies. CellarCool reserves the right to correct any errors, inaccuracies or omissions, and to change or update these Terms and Conditions, at any time without prior notice.
9. Questions, Additional Information And Technical Assistance
A. Questions. If you have any questions regarding these Terms and Conditions or wish to obtain additional
information, contact us via phone at 1-800-343-9463 or please send a letter via U.S. Mail to:
Customer Service CellarCool Corporation 1738 E Alpine Ave Stockton, CA 95205
Email: [email protected] Web: www.cellarcool.com
B. Technical Assistance. CellarCool Customer Service is available Monday through Friday from 6:30 a.m. to 4:00 p.m.
PST. The Customer Service representative will be able to assist you with your questions and warranty information more eectively if you provide them with the following:
1. The model and serial number of your CellarCool UNIT.
2. The location of the system and installation details, such as ventilation, construction of your wine cellar, and room size.
Page 20 | 1-855-235-5271
ACH 033114
Page 23
NOTES
Model ______________________________________ Serial Number __________________________
Installed by __________________________________________ Date __________________________
CACH 550
www.cellarcool.com | Page 21
Page 24
CellarCool
1738 E. Alpine Ave
Stockton, CA 95205
1(855) 235-5271
www.cellarcool.com
ACH 033114
Loading...