celesco SP1, SP1-12, SP1-4, SP1-4-3, SP1-12-3 Installation Manual

...
.54 [13,8]
1.40
[35,5]
1.38
[35,1]
1.38
[35,1]
.53
[13,4]
1.67
[42,5]
2.4” [60mm]
customer supplied electrical cable,
contact view
2
3
1
4
+in
com
+out
10K Ω
0% 100%
V(+out)
mating plug
(contact view)
2
3
1
4
1 - +in 2 - common 3 - +out 4 - n/c
+out
common
pin 1 - brown
pin 3 - blue
pin 2 - white
regulated DC supply (30V max)
+
optional cordset
#9036810-0040
+out
common
+in
common
regulated DC supply (30V max)
+
com (1)
+out (2)
+in (3)
SP1-xx-3 shown
*note: SP1-xx-3 shown
To change cable exit direction, simply remove the 3 mounting bracket screws and rotate sensor body to 1 of 4 options.
To change connector direction (SP1-xx-3 only), remove the 4 cover screws and carefully rotate to desired direction.
alternate connector
positions*
alternate cable exits*
celesco.com
Electrical Connection, SP1-xx Electrical Connection, SP1-xx-3 Output Signal / Circuit
alternate installation
Cable Exit/Connector Direction
SP1 Installation Guide
SP1-4 SP1-4-3 SP1-12 SP1-12-3 SP1-25 SP1-25-3 SP1-50 SP1-50-3
includes:
(SP1-xx-3 only)
Mating Plug
.54 [13,8]
1.40
[35,5]
1.38
[35,1]
1.38
[35,1]
.53
[13,4]
1.67
[42,5]
2.4” [60mm]
customer supplied electrical cable,
contact view
2
3
1
4
+in
com
+out
10K Ω
0% 100%
V(+out)
mating plug
(contact view)
2
3
1
4
1 - +in 2 - common 3 - +out 4 - n/c
+out
common
pin 1 - brown
pin 3 - blue
pin 2 - white
regulated DC supply (30V max)
+
optional cordset
#9036810-0040
+out
common
+in
common
regulated DC supply (30V max)
+
com (1)
+out (2)
+in (3)
1.85 [46,9]
2.00
[50,8]
.61
[15,5]
.70 [17,7]
.78 [19,9]
.38 [9,7]
1.40 [35,5]
1.90 [48,3]
.57 [14,6]
.80
[20,3]
3.55
[90,2]
in [mm] in [mm]
Ø.53 [13,3]
.54 [13,8]
3.60
[91,4]
Ø.53
[13,3]
1.10
[27,9]
1.00
[25,4]
.6
[15,2]
2.23 [56,6]
2.52 [64,0]
Ø.14 [3,7]
thru
(2 plc.)
.57
[14,4]
2.09 [53]
1.19
[30,1]
2.34 [59,5]
Ø1.47
[37,2]
in [mm]
.72
[18,3]
Ø.15 [3,9]
thru
(2 plc.)
2.23 [56,6]
in [mm]
.15 [3,9]
.19
[4,8]
.50
[12,7]
Ø.15 [3,9]
.165
[4,19]
Ø.191 [4,19]
Ø.375 [9,52]
.165
[4,19]
Ø.191 [4,19]
Ø.375 [9,52]
SP1-xx-3 shown
*note: SP1-xx-3 shown
To change cable exit direction, simply remove the 3 mounting bracket screws and rotate sensor body to 1 of 4 options.
To change connector direction (SP1-xx-3 only), remove the 4 cover screws and carefully rotate to desired direction.
version: 1.0 / item no: SP1-MANUAL
alternate connector
positions*
alternate cable exits*
celesco.com
Top View, SP1-xx
Specications
Front View, SP1-xx Front View, SP1-xx-3 Side View, SP1-xx Side View, SP1-xx-3
Electrical Connection, SP1-xx Electrical Connection, SP1-xx-3 Output Signal / Circuit
alternate installation
Cable Exit/Connector Direction
SP1 Installation Guide
SP1-4 SP1-4-3 SP1-12 SP1-12-3 SP1-25 SP1-25-3 SP1-50 SP1-50-3
includes:
(SP1-xx-3 only)
Mating Plug
Top View, SP1-xx-3
Stroke Range Options: 4.75, 12.5, 25 and 50 inches Accuracy
4.75-inch range: 1% fs. all others: .25% fs. Repeatability: ±.05% fs.
Enclosure: polycarbonate Measuring Cable: .019-in. dia. nylon-coated stainless Measuring Cable Tension: 7 oz. Max Cable Acceleration: 15 g
Input Resistance: 10K ohms, ±10% Sensor: plastic hybrid potentiometer Recommended maximum input voltage 30V (AC/DC) Power Rating: 2 W at 70°F (21°C) Operating Temp: 0°-160°F (-18° to 71°C)
Complete Specs: celesco.com/_datasheets/sp1.pdf