CELER CMM6003-SC Datasheet

3236 Scott Boulevard Santa Clara, California 95054 Phone: (408) 986-5060 Fax: (408) 986-5095
CMM6003-SC
Features
50 MHz to 870 MHz Frequency Range
+41 dBm Output IP3
1.6 dB Noise Figure (@450 MHz)
17 dB Gain
22 dBm P1dB
Single Power Supply
+3V to +5V Voltage Rail
Description
The CMM6003-SC is a high dynamic range amplifier designed for applications operating within the 50 MHz to 870 MHz frequency range. It is an ideal solution for transmit and receive functions where high linearity is required.
The amplifier has the flexibility of being optimized for a number of wireless applications. The combination of
gain flatness, bandwidth, low NF and high IP3 at the same bias point make it an ideal transmit or receive solution when used in intermediate frequency applications.
The CMM6003-SC is packaged in a low-cost, space efficient, surface mount SOT-89 package which provides excellent electrical stability and low thermal resistance. All devices are 100% RF (at 800 MHz) and DC tested.
50 MHz to 870 MHz
High Dynamic Range
Amplifier
Advanced Product Information May 2003
(1 of 5)
Functional Block Diagram
Absolute Maximum Ratings
Parameter Rating Parameter Rating Parameter Rating
Supply Voltage +6.0 V Storage Temperature -55°C to +125°C Operating Temperature -40°C to +85°C RF Input Power +10 dBm Junction Temperature 150°C Thermal Resistance 59°C/W
Parameter Condition Min Typ Max Units
Frequency Range 50 800 870 MHz Gain Externally matched 15 17 18 dB Input Return Loss Externally matched -11 dB Output IP3 +41 dBm Noise Figure @50 MHz 1.9 dB
Noise Figure @ 800 MHz 3.3 dB Output P1dB 22 dBm Operating Current Range 120 150 180 mA Supply Voltage 5.0 V
Electrical Characteristics
Unless otherwise specified, the following specifications are guaranteed at room temperature in a Celeritek test fixture.
Notes:
1. T = 25°C, Vdd = 5.0, Frequency = 800 MHz, 50 Ohm system
2. OIP3 measured with two tones at output power of 10 dBm/tone separated by 10 MHz.
Operation of this device above any of these parameters may cause damage.
Parameter Typical Units
Frequency Range 450 800 870 MHz Gain 17.2 16.5 16.25 dB Input Return Loss -12.0 -11.5 -10.5 dB Output Return Loss -16 -14 -13 dB Output IP3 +39 +41 +41 dBm Output P1dB 23.6 23.7 23.8 dBm Noise Figure 1.6 1.9 2.0 dB
Typical Parameters
Notes:
1. Typical values reflect performance in recommended application circuit.
Input
Ground Output
Bias
Ground
1
2
3
4
3236 Scott Boulevard, Santa Clara, California 95054 Phone: (408) 986-5060 Fax: (408) 986-5095
CMM6003-SC
Advanced Product Information - May 2003
(2 of 5)
IP3 measured with 2 tones at an output power of 10 dBm/tone separated by 10 MHz
S-Parameters vs Frequency
Loading...
+ 3 hidden pages