CELER CMM6001-SC Datasheet

3236 Scott Boulevard Santa Clara, California 95054 Phone: (408) 986-5060 Fax: (408) 986-5095
CMM6001-SC
Features
60 MHz to 3.0 GHz Frequency Range
38 dBm Output IP3
2.5 dB Noise Figure
12.3 dB Gain
20.5 dBm P1dB
Single Power Supply
+3V to +5V Voltage Rail
Description
The CMM6001-SC is a high dynamic range amplifier designed for applications operating within the 60 MHz to 3.0 GHz frequency range. It is an ideal solution for transmit and receive functions where high linearity is required.
The amplifier has the flexibility of being optimized for a number of wireless applications. The combination of low NF and high IP3 at the same bias point make it an ideal trans­mit or receive solution when used in applications including
cellular and PCS (personal communications service) operating from 0.8 to 2.2 GHz; MMDS (multichannel multipoint distrib­ution systems) operating from 2.2 to 2.7 GHz; and WLAN (wireless LAN) operating at 2.4 GHz.
The CMM6001-SC is packaged in a low-cost, space efficient, surface mount SOT-89 package which provides excellent electrical stability and low thermal resistance. All devices are 100% RF and DC tested.
60 MHz to 3.0 GHz
High Dynamic Range
Amplifier
Advanced Product Information April 2003
(1 of 4)
Functional Block Diagram
Absolute Maximum Ratings
Parameter Rating Parameter Rating Parameter Rating
Supply Voltage +6.0 V Storage Temperature -55°C to +125°C Operating Temperature -40°C to +85°C RF Input Power +10 dBm Junction Temperature 150°C Thermal Resistance 150°C/W
Parameter Condition Min Typ Max Units
Frequency Range 0.60 3.0 GHz Gain Externally matched 10.5 12.5 dB Input Return Loss Externally matched -10 dB Output IP3 +33 +36 dBm Noise Figure 2.5 2.8 dB Output P1dB 20.5 dBm Operating Current Range 55 75 100 mA Supply Voltage 5.0 V
Electrical Characteristics
Unless otherwise specified, the following specifications are guaranteed at room temperature in a Celeritek test fixture.
Notes:
1. T = 25°C, Vdd = 5.0, Frequency = 800 MHz, 50 Ohm system
2. OIP3 measured with two tones at output power of 5 dBm/tone separated by 10 MHz.
Operation of this device above any of these parameters may cause damage.
Parameter Typical Units
Frequency Range 900 1900 2400 MHz Gain 12.5 11.5 10.8 dB Input Return Loss -18.0 -11.5 -10.0 dB Output Return Loss -17 -16 -15 dB Output IP3 +36 +36 +36 dBm Output P1dB 20.5 19.5 19.5 dBm Noise Figure 2.7 2.8 2.9 dB
Typical Parameters
Notes:
1. Typical values reflect performance in recommended application circuit.
Input
Ground Output
Bias
Ground
1
2
3
4
3236 Scott Boulevard, Santa Clara, California 95054 Phone: (408) 986-5060 Fax: (408) 986-5095
CMM6001-SC
Advanced Product Information - April 2003
(2 of 4)
Application Circuit
RF
OUT
uuuu
uuuu
C4
56 pF
L2 12 nH
Vcc 5V
C2
56 pF
L1
10 nH
RF IN
CMM6001-SC
SOT-89
T = 100 mil
INPUT MATCHING NETWORK
C1
56 pF
T = 70 mil
20
10
0
-10
-20
-30
-40
0.5 1.0 1.5 2.0 2.5 3.0 Frequency, GHz
Magnitude, dB
S21
S11
S22
S-Parameters vs Frequency
Ref Designator Value Description Size
C1, C4 56 pF MCH185A560JK 0603 C2 0.1 µF VITR 0.1µF 25V CER 0603
CAP 0603 X7R 10% L1 10 nH TOKO LL1608-F10NJ 0603 L2 12 nH TOKO LL1608-F12NK 0603
T = 375 mil T = 485 mil
Parameter Typical Units
Frequency Range 900 1900 2400 MHz Gain 12.5 11.5 10.8 dB Input Return Loss -18.0 -11.5 -10.0 dB Output Return Loss -17 -16 -15 dB Output IP3 +36 +36 +36 dBm Output P1dB 20.5 19.5 19.5 dBm Noise Figure 2.7 2.8 2.9 dB
Notes:
1. Typical values reflect performance in recommended application circuit.
Loading...