CEL ZICM0868P0-1CU, ZICM0868P2-1CU, ZICM0900P, ZICM0868P0-1CS, ZICM0868P0-1C Preliminary Data Sheet

...
PRELIMINARY DATA SHEET
MeshConnect™ Sub-G Module Series
ZICM0868Px ZICM0900Px
868 / 900 MHz Transceiver Based Modules
Development Kits Available:
ZICM0868P2-KIT1-1 and ZICM0900P2-KIT1-1
DESCRIPTION
CEL's MeshConnect™ Module Series provides high performance and low cost Sub-G modules for a broad range of wireless net-
works. The MeshConnect certied and qualied modules enable
customers to accelerate time to market by greatly reducing design
and certication phases of development.
CEL's MeshConnect™ Sub-G modules (868/900MHz) are based on the Silicon Labs SoC ICs (single-chip solutions). Each IC con­sists of an RF transceiver with baseband modem, a hard-wired MAC and an embedded 8051 microcontroller with internal RAM (4kB) and Flash (64kB) memory. The device provides numer­ous general-purpose I/O pins and peripheral functions such as timers and UARTs.
The MeshConnect Sub-G modules have 2 different output powers (+12dBm and +19dBm). They provide a reliable transmission, to reduce the number of nodes in a network. They are especially useful for open outdoor applications where the nodes are physi­cally far apart. The higher power Modules have an outstanding
118dB link budget ensuring high quality connections even in
harsh environments.
APPLICATIONS
• Metering
• RFID
• RemoteKeylessEntry
• HomeAutomation
• Security
• Irrigation
• WeatherStations
• Andmore...
MeshConnect
ZICM0868Px ZICM0900Px
Sub-G Modules
Best Reliable Performance
• Good sensitivity providing longer range for Non-line-of-site
aplications
• Low operating (receive) current
FEATURES
•FrequencyRange:
 902- 928 MHz   868 MHz
•Sensitivity:-99dBm
•MaxOutputPower:
+ 12 dBm @ 3.6 VDC (ZICM0xxxP0)
+ 19 dBm @ 3.6 VDC (ZICM0xxxP2)
•DataRate:0.123to150kbps
•Upto21GPIOPins
•HighSpeed8051MCU:
30 MHz 4kB RAM / 64 kB Flash
•10-BitADC:
300 ksps, 18-ch inputs
•SerialCommunication:
UARTs, SPI (Master/Slave) SMBus, PCA
•Modulation:   FSK
•RFPowerConsumption
24 mA Receive 18 mA @ + 1 dBm transmit   30 mA @ + 12 dBm transmit 90 mA @ + 19 dBm transmit
•Auto-FrequencyCalibration(AFC)
•FrequencyHoppingCapability
•Upto12milesofrange
•OperatingTemperatureRange:  -40 to +85ºC
•SoftwareSupport:  Synapse SNAP Embedded Firmware  Wireless M-Bus (868MHz Only) Silicon Labs EZMac CEL Protocol
•FCC,CEandICcerticationsin  Progress
•ROHScompliant
The information in this document is subject to change without notice, please conrm data is current
Document No: 0009-00-07-00-000 (Issue ES)
Date Published: December 7, 2010
Page 1
ORDERING INFORMATION
Part Number Order Number Description
ZICM0868P0-1CU 868 MHz Module, +12dBm output power with U.FL connector for external antenna
ZICM0868P2-1CU 868 MHz Module, +19dBm output power with U.FL connector for external antenna
ZICM0868P0-1CS 868 MHz Module, +12dBm output power with RP-SMA connector for external antenna
ZICM0868P2-1CS 868 MHz Module, +19dBm output power with RP-SMA connector for external antenna
ZICM0868P0-1C
ZICM0868P2-1C
MeshConnect™ Sub-G
(Eruope Only)
MeshConnect™ Sub-G
MeshConnect™ Sub-G
Development Kits
ZICM0868P0-1CU-SN
ZICM0868P2-1CU-SN
ZICM0868P0-1CS-SN
ZICM0868P2-1CS-SN
ZICM0868P0-1C-SN
ZICM0868P2-1C-SN
ZICM0900P0-1CU 900 MHz Module, +12dBm output power with U.FL connector for external antenna
ZICM0900P2-1CU 900 MHz Module, +19dBm output power with U.FL connector for external antenna
ZICM0900P0-1CS 900 MHz Module, +12dBm output power with RP-SMA connector for external antenna
ZICM0900P2-1CS 900 MHz Module, +19dBm output power with RP-SMA connector for external antenna
ZICM0900P0-1C
ZICM0900P2-1C
ZICM0900P0-1CU-SN
ZICM0900P2-1CU-SN
ZICM0900P0-1CS-SN
ZICM0900P2-1CS-SN
ZICM0900P0-1C-SN
ZICM0900P2-1C-SN
ZICM0868P2-KIT1-1 868 MHz Evaluation board for +19 dBm module
ZICM0900P2-KIT1-1 900 MHz Evaluation board for +19 dBm module
MeshConnect™ Sub-G Module Series
868 MHz Module, +12dBm output power with a connection for 1/4 wave wire antenna (in place of RP-SMA)
868 MHz Module, +19dBm output power with a connection for 1/4 wave wire antenna (in place of RP-SMA)
868 MHz Module, +12dBm output power with U.FL connector for external antenna with SNAP Operating System software and MAC address
868 MHz Module, +19dBm output power with U.FL connector for external antenna with SNAP Operating System software and MAC address
868 MHz Module, +12dBm output power with RP-SMA connector for external antenna with SNAP Operating System software and MAC address
868 MHz Module, +19dBm output power with RP-SMA connector for external antenna with SNAP Operating System software and MAC address
868 MHz Module, +12dBm output power for 1/4 wave wire antenna (in place of RP-SMA) with SNAP Operating System software and MAC address
868 MHz Module, +19dBm output power for 1/4 wave wire antenna(in place of RP-SMA) with SNAP Operating System software and MAC address
900 MHz Module, +12dBm output power with a connection for 1/4 wave wire antenna (in place of RP-SMA)
900 MHz Module, +19dBm output power with a connection for 1/4 wave wire antenna (in place of RP-SMA)
900 MHz Module, +12dBm output power with U.FL connector for external antenna with SNAP Operating System software and MAC address
900 MHz Module, +19dBm output power with U.FL connector for external antenna with SNAP Operating System software and MAC address
900 MHz Module, +12dBm output power with RP-SMA connector for external antenna with SNAP Operating System software and MAC address
900 MHz Module, +19dBm output power with RP-SMA connector for external antenna with SNAP Operating System software and MAC address
900 MHz Module, +12dBm output power for 1/4 wave wire antenna (in place of RP-SMA) with SNAP Operating System software and MAC address
900 MHz Module, +19dBm output power for 1/4 wave wire antenna (in place of RP-SMA) with SNAP Operating System software and MAC address
Page 2
MODULE BLOCK DIAGRAM
ANT
SI100x
MeshConnect™ Sub-G Module Series
Sub-G
T/R
Switch
External Memory
Optional
Low Pass
Filter
DEVELOPMENT KIT
CEL's Development Kit assist users in both evaluation and development. As a stand-alone radio system, the kit allows users to place the modules into the target environment and evaluate performance on-site. The Development Kit also serves as an invaluable aid in application develop­ment. Through the many interface headers on the board, the user has access to all of the MeshConnect module pins, enabling easy connection to target systems for ap­plication development.
The interface board features a serial communication interface, a power management module, and peripherals such as a buzzer, push-button switches, LEDs, and GPIO headers.
MeshConnect
Sub-G Module Development Kit
For more detail information regarding MeshConnect Development Kits, refer to the respective development kit user guides documents. (Available at CEL’s website
http://www.cel.com)
DEVELOPMENT KIT ORDERING INFORMATION
Part Number Order Number Description
MeshConnect™ Sub-G
Development Kits
ZICM0868P2-KIT1-1 868 MHz Evaluation board for +19dBm module
ZICM0900P2-KIT1-1 900 MHz Evaluation board for +19dBm module
Kit Contents:
• Evaluation Boards w/Module (2)
• USB Cables (1)
• AA Batteries (4)
• Software & Technical Information CD (1)
Page 3
TABLE OF CONTENTS
Introduction and Overview
MeshConnect™ Sub-G Module Series
Description..............................................................................................................................................................................................
Features..................................................................................................................................................................................................
Applications............................................................................................................................................................................................
Ordering Information.............................................................................................................................................................................
Module Block Diagram........................................................................................................................................................................... 3
Development Kit..................................................................................................................................................................................... 3
System Level Function
Transceiver IC.........................................................................................................................................................................................
Antenna.................................................................................................................................................................................... 5
Additional Flash Memory....................................................................................................................................................................... 5
Electrical Specication
Absolute Maximum Ratings...................................................................................................................................................................
Recommended (Operating Condition)..................................................................................................................................................
DC Characteristics..................................................................................................................................................................................
RF Characteristics..................................................................................................................................................................................
Pin Signal & Interfaces
Pin Signals I/O Conguration................................................................................................................................................................
I/O Pin Assignment.................................................................................................................................................................................
Software/Firmware..................................................................................................................................................................................
Module Dimensions................................................................................................................................................................................
Module Footprint....................................................................................................................................................................................
1
1
1
2
5
6
6
6
7
8
8
9
10
11
Processing.........................................................................................................................................................................................
Agency Certications...................................................................................................................................................................
Shipment, Storage & Handling.................................................................................................................................................
References & Revision History.................................................................................................................................................
12
13
14
15
Page 4
MeshConnect™ Sub-G Module Series
TRANSCEIVER IC
The MeshConnect Sub-G modules are based on the Silicon Labs Si1000 and Si1002 SOC transceiver ICs. These ICs incorporate the RF transceiver with the baseband modem, a hardwired MAC, and an embedded 8051 microcontroller, offering a high performance solution for all Sub-G applications.
For more information about the Silicon Labs ICs, visit http://www.silabs.com.
ANTENNA
The MeshConnect Sub-G modules include RF connectors for external antenna options only (There is no trace antenna option). The following options are supported by CEL:
U.FL connector
RP-SMA connector
A Connection for 1/4 wave wire antenna in place of RP-SMA
Here are some design guidelines to help ensure antenna performance:
Never place the antenna close to metallic objects.
In the overall design, ensure that wiring and other components are not placed near the antenna.
Do not place the antenna in a metallic or metalized plastic enclosure.
Keep plastic enclosures 1cm or more from the antenna in any direction.
ADDITIONAL FLASH MEMORY (Optional)
The Silicon Labs Transceiver ICs (Si1000 and Si1002) have an embedded 64kB of ash. Additional memory (1MB) can be
mounted on the module (as an option) to enable Over The Air (OTA) programming capability.
This is a custom solution as an option for all part numbers.
Page 5
ABSOLUTE MAXIMUM RATINGS
MeshConnect™ Sub-G Module Series
Description
Power Supply Voltage (VDD) -0.3 3.6 VDC
Voltage on any I/O Line -0.3 VDD + 0.3 VDC
RF Input Power
Storage Temperature Range -40 125 °C
Reow Soldering Temperature 260 °C
Note: Exceeding the maximum ratings may cause permanent damage to the module or devices.
RECOMMENDED (OPERATING CONDITIONS)
Description
Power Supply Voltage (VDD)
Input Frequency
Input Frequency 902 928 MHz
Ambient Temperature Range -40 25 85 °C
Note: * 2.7v is the min voltage if an additional memory IC was placed on the module.
MeshConnectSub-G Module
Min Max
10
MeshConnectSub-G Module
Min Typ Max
1.8/2.7*
863
3.3 3.6 V
Unit
dBm
870
DC CHARACTERISTICS (@ 25°C, VDD = 3.6V, ZICM0xxxP2 TX power max)
Unit
MHz
Description
Transmit Mode Current
Receive Mode Current
Sleep Mode Current
MeshConnectSub-G Module
Min Typ Max
90
24
TBD
mA
mA
µA
DC CHARACTERISTICS (@ 25°C, VDD = 3.6V, ZICM0xxxP0 TX power max)
Description
Transmit Mode Current 35 mA
Receive Mode Current 24 mA
Sleep Mode Current TBD µA
MeshConnectSub-G Module
Min Typ Max
Unit
Unit
Page 6
RF CHARACTERISTICS (@ 25°C, VDD = 3.6V, ZICM0xxxP2)
MeshConnect™ Sub-G Module Series
Description
General Characteristics
RF Frequency Range
Transmitter
Maximum Output Power
Minimum Output Power
FSK Error TBD TBD
Carrier Offset TBD TBD KHz
Deviation 75 KHz
Receiver
Sensitivity (1% PER, 156kbps)
Saturation (maximum input level)
MeshConnectSub-G Module
Min Typ Max
863
19
-5
-99 TBD
928
dBm
dBm
10
RF CHARACTERISTICS (@ 25°C, VDD = 3.6V, ZICM0xxxP0)
Description
General Characteristics
RF Frequency Range 863 928 MHz
Transmitter
Maximum Output Power 12 dBm
Minimum Output Power -12 dBm
FSK Error TBD TBD %
Carrier Offset TBD TBD KHz
Deviation 75 KHz
Receiver
Sensitivity (1% PER, 156kbps) -99 TBD dBm
Saturation (maximum input level) 10 dBm
MeshConnectSub-G Module
Min Typ Max
Unit
MHz
%
dBm
dBm
Unit
Page 7
MeshConnect™ Sub-G Module Series
PIN SIGNALS I/O PORT CONFIGURATION
MeshConnect module has 56 edge I/O interfaces for connection to the user’s host board. The MeshConnect Module Dimensions shows the layout of the 56 edge castellations.
MeshConnect I/O PIN ASSIGNMENTS
Number Name Notes
1 GND
2 GND
3 GND
4 GND
5 GND
6 GND
7 GND
8 NC
9 ANTA Available: Not used for any module funconality
10 GPIO0 Available: Not used for any module funconality
11 GPIO2 Available: Not used for any module funconality
12 P0.7/IREF Must be connected to SDN for SNAP rmware
P0.6/
13
14 P0.5/RXD UART TXD
15 P0.4/TXD UART RXD
16 WP Write Protect Pin of Memory Chip on Module
17 NC
18 GND
19 GND
20 NC
21 NC
22 NC
23 P0.3 Used as Chip Select for Memory IC on the CEL Module
24 P0.2 Memory IC MISO signal pin
25 P0.1 Must be connected to NIRQ for SNAP rmware
26 P0.0 Memory IC Clock Signal
27 GND
28 VCC
29 RST/C2CK Debug Clock
30 P2.7/C2D Debug Data
31 P2.6 GPIO connected to Buzzer on CEL Eval Board
32 P2.5 GPIO connected to Switch 3 on CEL Eval board
33 P2.4 GPIO connected to LED3 on CEL Eval board
34 P2.3 GPIO connected to Switch 2 on CEL Eval Board
CNVSTR Used as Chip Select for Memory on CEL Eval. Board
Page 8
MeshConnect I/O PIN ASSIGNMENTS (Continued)
Number Name Notes
35 NC
36 NC
37 GND
38 GND
39 GND
40 GND
41 GND
42 P2.2 GPIO connected to LED2 on CEL Eval board
43 P2.1 GPIO connected to Switch 1 on CEL Eval Board
44 P2.0 GPIO connected to LED1 on CEL Eval board
45 P1.7 GPIO connected to Switch 0 on CEL Eval Board
46 P1.6 GPIO connected to LED0 on CEL Eval board
47 P1.5 Memory IC MOSI
48 NIRQ External Interrupt Request
49 SDN Radio Shutdown (Acve High)
50 GND
51 GND
52 GND
53 GND
54 GND
55 GND
56 GND
MeshConnect™ Sub-G Module Series
SOFTWARE/FIRMWARE
The Sub-G modules support the following software:
• SynapseSNAPEmbeddedFirmware  • WirelessM-Bus(868MHzOnly)
• SiliconLabsEZMac  • CELProtocol
The MeshConnect Sub-G Development Kit provides a guide on how to access the Si100x IC and utilize the Silicon Labs software development environment. It also provides a set of demo applications to conduct several tests. Below is the list of the demo software features:
Page 9
MeshConnect™ Sub-G Module Series
SOFTWARE/FIRMWARE (Continued)
Self Healing (Orphan handling)
Point-to-Point network formation
Point-to-Multipoint (Star) network formation
Self Healing (Orphan handling)
Point-to-Point network formation
Point-to-Multipoint (Star) network formation
ACK
Wakeup Modes (Si100X) – most likely software will just use one of the wakeup modes
Frequency Hopping
Unicast Addressing using 16-bit device IDs
Broadcast Addressing
Packet Forwarding (Master node only)
Forwarding Table Aging (Master node only)
Promiscuous Mode (TBD – later release)
Listen Before Talk (LBT)
RSSI
Packet Filtering
Pairing/Joining
Network Synchronization through beacon messages to coordinate sleep/wake cycles
- Master node needs to send out beacon as well as gure out when to go to sleep and when to wake up
- End node wakes up and looks for beacon to gure out when to go to sleep and wake up
Command line interface for debug/testing/conguration
Push buttons for Range or PER packet test on a Eval board
Save conguration to ash
Save conguration to external ash
Over-the-air programming of the image to another device (TBD – later release)
Low Battery detection
MODULE DIMENSIONS
MeshConnect™ Sub-G Module with U.FL Connector for external antenna MeshConnect™ Sub-G Module with RPSMA Connector for external Antenna
For layout recommendation for optimum antenna performance, refer to Antenna section in this document.
Page 10
MODULE LAND FOOTPRINT
Note: Unless otherwise specied. Dimensions are in Inches [mm].
MeshConnect™ Sub-G Module Series
EVALUATION BOARD
CEL provides an Evaluation board to allow easy testing of the Module. The Evaluation board provides power via:
AA cell batteries
USB
AC Adapter regulated down to 3.3VDC
External Lab Power Supply (A jumper is also provided for the purposes of monitoring the DC current of
the module under various modes of operation).
Also included on the evaluation board are four momentary push button switches and four LEDs, a piezo buzzer, a potenti-
ometer, and a SPI memory IC. The peripherals are connected to GPIO of the module (see notes in Pin denitions) through slide switches. If the user would wants to connect user specic circuits to the GPIO, slide switches can be used to discon-
nect the evaluation board peripherals.
The purpose of the evaluation board is to demonstrate simple applications of using GPIO, communicating with the device
and also allow exibility for user specic needs.
Page 11
MeshConnect™ Sub-G Module Series
PROCESSING
Recommended Reow Prole
Parameters Values
Ramp up rate (from Tsoakmax to Tpeak) 3º/sec max
Minimum Soak Temperature 150ºC
Maximum Soak Temperature 200ºC
Soak Time 60-120 sec
TLiquidus 217ºC
Time above TL 60-150 sec
Tpeak 250ºC
Time within 5º of Tpeak 20-30 sec
Time from 25º to Tpeak 8 min max
Ramp down rate 6ºC/sec max
Achieve the brightest possible solder llets with a good shape and low contact angle.
Pb-Free Soldering Paste
Use of “No Clean” soldering paste is strongly recommended, as it does not require cleaning after the soldering process.
Note: The quality of solder joints on the castellations (‘half vias’) where they contact the host board should meet the appropriate IPC Speci-
cation. See the latest IPC-A-610 "Acceptability of Electronic Assemblies, section 8.2.4 Castellated Terminations.”
Cleaning
In general, cleaning the populated modules is strongly discouraged. Residuals under the module cannot be easily removed with any cleaning process.
• Cleaning with water can lead to capillary effects where water is absorbed into the gap between the host board and the module. The combination of soldering ux residuals and encapsulated water could lead to short circuits between neighboring pads. Water could also damage any stickers or labels.
• Cleaning with alcohol or a similar organic solvent will likely ood soldering ux residuals into the two housings, which
is not accessible for post-washing inspection. The solvent could also damage any stickers or labels.
• Ultrasonic cleaning could damage the module permanently.
The best approach is to consider using a “no clean” soldering paste and eliminate the post-soldering cleaning step.
Optical Inspection
After soldering the Module to the host board, consider optical inspection to check the following:
• Proper alignment and centering of the module over the pads.
• Proper solder joints on all pads.
• Excessive solder or contacts to neighboring pads, or vias.
Repeating Reow Soldering
Only a single reow soldering process is encouraged for host boards.
Wave Soldering
If a wave soldering process is required on the host boards due to the presence of leaded components, only a single wave
soldering process is encouraged.
Page 12
MeshConnect™ Sub-G Module Series
PROCESSING (Continued)
Hand Soldering
Hand soldering is possible. Use a soldering iron temperature setting equivalent to 350°C, follow IPC recommendations/ reference document IPC-7711.
Rework
The MeshConnect Module can be unsoldered from the host board. Use of a hot air rework tool and hot plate for pre-heating from underneath is recommended. Avoid overheating.
Warning Never attempt a rework on the module itself, e.g. replacing individual components. Such actions will
terminate warranty coverage.
Additional Grounding
Attempts to improve module or system grounding by soldering braids, wires, or cables onto the module RF shield cover is done at the customer's own risk. The numerous ground pins at the module perimeter should be sufcient for optimum
immunity to external RF interference.
AGENCY CERTIFICATIONS
FCC Compliance Statement (Part 15.19) Section 7.15 of RSS-GEN
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
Warning (Part 15.21)
Changes or modications not expressly approved by CEL could void the user's authority to operate the equipment.
20 cm Separation Distance
To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
OEM Responsibility to the FCC Rules and Regulations
The MeshConnect Module has been certied per FCC Part 15 rules for integration into products without further testing or certication. To fulll the FCC certication requirements, the OEM of the MeshConnect Module must ensure that the information provided on the MeshConnect Label is placed on the outside of the nal product. The MeshConnect Module is
labeled with its own FCC ID Number. If the FCC ID is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This
exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: W7Z-ICP0” or “Contains FCC ID: W7Z-ICP0”
The OEM of the MeshConnect Module must only use the approved antenna, (PCB Trace Antenna) that has been certied with this module. The OEM of the MeshConnect Module must test their nal product conguration to comply with Uninten-
tional Radiator Limits before declaring FCC compliance per Part 15 of the FCC rules.
Page 13
MeshConnect™ Sub-G Module Series
AGENCY CERTIFICATIONS (Continued)
IC Certication — Industry Canada Statement
The term "IC" before the certication / registration number only signies that the Industry Canada technical specications
were met.
Section 14 of RSS-210
The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit RF eld in
excess of Health Canada limits for the general population. Consult Safety Code 6, obtainable from Health Canada's website: http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/99ehd-dhm237/index-eng.php
CE Certication — Europe
The MeshConnect 868MHz RF modules has been tested and certied for use in the European Union.
OEM Responsibility to the European Union Compliance Rules
If the MeshConnect module is to be incorporated into a product, the OEM must verify compliance of the nal product to the
European Harmonized EMC and Low-Voltage / Safety Standards. A Declaration of Conformity must be issued for each of
these standards and kept on le as described in Annex II of the R&TTE Directive.
The manufacturer must maintain the user's guide and adhere to the settings described in the manual for maintaining
European Union Compliance. If any of the specications are exceeded in the nal product, the OEM is required to make a submission to the notied body for compliance testing.
OEM Labeling Requirements
The `CE' mark must be placed on the OEM product in a visible location. The CE mark shall consist of the initials “CE” with the following form:
· If the CE marking is reduced or enlarged, the proportions given in the above graduated drawing must be adhered to.
· The CE mark must be a minimum of 5mm in height
· The CE marking must be afxed visibly, legibly, and indelibly. Since the 2400 - 2483.5 MHz
band is not harmonized by a few countries throughout Europe, the Restriction sign must be placed to the right of the “CE” marking as shown in the picture
SHIPMENT, HANDLING, AND STORAGE
Shipment
The MeshConnect Modules are delivered in trays of 28.
Handling
The MeshConnect Modules are designed and packaged to be processed in an automated assembly line.
Warning The MeshConnect Modules contain highly sensitive electronic circuitry. Handling without proper ESD
protection may destroy or damage the module permanently.
Warning According to JEDEC ISP, the MeshConnect Modules are moisture-sensitive devices. Appropriate handling instruc-
tions and precautions are summarized in Section 2.1. Read carefully to prevent permanent damage due to moisture intake.
Moisture Sensitivity Level (MSL)
MSL 3, per J-STD-033
Storage
Storage/shelf life in sealed bags is 12 months at <40°C and <90% relative humidity.
Page 14
REFERENCES & REVISION HISTORY
MeshConnect™ Sub-G Module Series
Previous Versions Changes to Current Version
0008-00-07-00-000 (Issue ES) December 7, 2010
Initial preliminary datasheet.
Disclaimer
• The information in this document is current as of the published date. The information is subject to change without
notice. For actual design-in, refer to the latest publications of CEL data sheets or data books, etc., for the most
up-to-date specications of CEL products. Not all products and/or types are available in every country. Please
check with an CEL sales representative for availability and additional information.
• No part of this document may be copied or reproduced in any form or by any means without the prior written
consent of CEL. CEL assumes no responsibility for any errors that may appear in this document.
• CEL does not assume any liability for infringement of patents, copyrights or other intellectual property rights of
third parties by or arising from the use of CEL products listed in this document or any other liability arising from the use of such products. No license, express, implied or otherwise, is granted under any patents, copyrights or other intellectual property rights of CEL or others.
• Descriptions of circuits, software and other related information in this document are provided for illustrative
purposes in semiconductor product operation and application examples. The incorporation of these circuits,
software and information in the design of a customer’s equipment shall be done under the full responsibility of the
customer. CEL assumes no responsibility for any losses incurred by customers or third parties arising from the use of these circuits, software and information.
• While CEL endeavors to enhance the quality, reliability and safety of CEL products, customers agree and
acknowledge that the possibility of defects thereof cannot be eliminated entirely. To minimize risks of damage to property or injury (including death) to persons arising from defects in CEL products, customers must incorporate
sufcient safety measures in their design, such as redundancy, re-containment and anti-failure features.
Page(s)
N/A
Page 15