Ceke DTV-UDWG100F User Manual

DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D08, Information Industrial Park, Chao Yang Road, Hightech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
Wide Band Frequency Repeater
User Manual
Guilin CEKE Communication Equipment Co., Ltd.
June, 2012,
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
1
Dear customers: Thanks for your purchase! The manual is prepared for you so that you can have a better understanding of the
product and make better use of this machine either for operation or maintenance in short time. Please make sure you review all documents we provide carefully before installation so that you make full use of this machine.
We are serious about this manual and hope you can get complete and reliable information from it. Please call us or e-mail us if you have any questions. Thanks for your support and cooperation.
The Company CEKE reserves the right of the final interpretation of the relevant information in this manual.
Guilin CEKE Communication Equipment Co., Ltd. Tel: +86 773 2120156 Fax: +86 773 2120299 E-mail: glsq@glsq.com Web: www.glsq.com
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
2
Content
1. Model Description ............................................................................................................... 3
2Product Configuration ........................................................................................................ 3
2-1Product Standard Configuration ........................................................... 3
2-2Products Optional Configuration .......................................................... 4
3Product Safety Instructions ................................................................................................ 4
3-1Security measures ................................................................................. 4
3-2Security Protection ............................................................................... 4
3-3Electrostatic Induction .......................................................................... 5
4Product Installation Instructions ........................................................................................ 5
4-1Unpacking Inspection ........................................................................... 5
4-2Safety Requirements ............................................................................. 6
4-3Rack Mounting ..................................................................................... 6
4-4Accessories Installation ........................................................................ 6
4-5Cleaning and Maintenance ................................................................... 7
4-6Notes ..................................................................................................... 7
5System Functional Block Diagram .................................................................................... 8
6Function Features ............................................................................................................... 9
7Performance Indicators and Parameters ........................................................................... 11
8Interface Introduction ....................................................................................................... 13
9.1 Repeater 3.3 Program Client Interface Introduction: ............................. 15
1 .Equipment information ............................................................................ 16
2 . Alarm ....................................................................................................... 17
3 . SETUP system settings ........................................................................... 18
4SYSTEM SET GPRS GPRS setting ............................................... 20
9.2 Repeater 3.52 Program Client Interface Introduction: ........................... 23
4SYSTEM SET GPRS GPRS setting ............................................... 24
10Fault Description ............................................................................................................ 27
11.Warranty Card ................................................................................................................ 28
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
3
1. Model Description
AAA-××WG00F-0000A
Application
Field
Operation
Wavelength
Amplifier
Mode
Operation
Bandwidth
Equipment
Function
Maximum
Power
auxiliary
cooling
Volume
production
time
Equipment
Version
U-U band
S-S band L-L band
V-V band
D-digital
A-anolog
Broadband
work
Signal
Gap-fill
Fan
Year/Month
DTV-UDWG50F-0910A
Application
Field
Operation
Wavelength
Amplifier
Mode
Operation
Bandwidth
Equipment
Function
Maximum
Power
auxiliary
cooling
Volume
production
time
Equipment
Version
UHF
Band
Digital
Amplifier
Broadband
work
Signal
Gap-fill
Fan
auxiliary
cooling
Oct,2009
Digital TV
50w Average
Power
A
2Product Configuration
DTV-UDWG series terrestrial digital TV repeaters include 12 different power level series products as follows: 10mW, 20mW, 50mW, 100mW, 200mW, 1W, 5W, 10W, 20W, 50W, 100W, 200W. The functions and applications could be set up depending on various functions and applied fields.
2-1Product Standard Configuration
The standard configuration of DTV-UDWG series digital TV repeater includes: small-signal pre-amplifier module, final power amplifier module, power module, waterproof cabinet, cooling components, and installation accessories.
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
4
2-2Products Optional Configuration
To meet the needs of different requirements and applications, DTV-UDWG Series Digital TV Repeater is designed with a variety of optional modules for different functions.
Module Name
Summary function
GPRS Monitoring Module
Remote wireless monitoring and maintenance
Optical Receiver Module
To support the optical signal input
Input Filter
Clutter filter in frequency outside the user-specified frequency
Output Filter
Out-band Clutter filter of equipment output
MMDS Down-conversion
Receiver Module
To support the microwave signal input
Input RF Delay Module
Make the equipment support the wideband low-power
single-frequency networking
3Product Safety Instructions
3-1Security measures
Equipment described in this manual must be operated by trained professionals. Besides the general safety procedures, the operator and service persons should also comply with safety precautions measures in this manual. Please refer to the relevant section to have the details of the relevant technical specifications, installation and operating instructions etc.
Please pay special attention to the following situations:
The equipments must have Ground Protection.
Check the actual environmental conditions according to specified requirements.
Power supply voltage must be within the limits as prescribed.
3-2Security Protection
This manual provides the important technical information on how to operate the
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
5
machine safely. Technical specifications could be found in Product Description section .The installation and operation section describes how to use this product in details.
Equipment power supply:
220V ± 20% / 50/60 Hz
Maximum rated input power:
Nominal output power
10mW
20mW
50mW
100mW
200mW
1W
Maximum rated input power
5W
6W
10W
10W
12W
30W
Nominal output power
5W
10W
20W
50W
100W
200W
Maximum rated input power
50W
70W
100W
400W
600W
1000W
Operating Environment:
Outdoors
Within 5000m above sea level
-25 ~ +55 ℃; relative humidity ≤ 95%, water-resistant
Please stop the machine and contact maintenance and service team immediately whenever abnormality occurs.
3-3Electrostatic Induction
When repairing the equipment, it is required to wear a grounded wrist strap in order to prevent static electricity, in addition, be sure that the components and tools are grounded.
4Product Installation Instructions
4-1Unpacking Inspection
Before installing repeater, please check and verify the following items in the list.
Repeater one set
Mounting screws one set
The power cord one set
Manual (including attached warranty card) one
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
6
Installing clamp (for models 1W) 2 sets
Optional accessories one set
If any parts are missing or damaged, please contact the supplier.
4-2Safety Requirements
Before installing the equipment, the user should check whether the AC input voltage range is within the equipment allowable range or not; check the ground connection is intact or not. Please make sure the isolation degrees between the transmitting antenna and RF input should be greater than the equipment nominal isolation degrees. Please check all correct cables connections before the installation.
4-3Rack Mounting
Outdoor repeater can be installed on the wall or on the pole. When the equipment is installed in the wall, the user can use screws or expansion screws to fix instead of clamps. As for rack installation, please pay special attention to the environment around, the rack should be installed in the shade with good ventilation. There should be no block material within the range of 50CM, under or above.
Please refer to diagram below to finish the installation.
Screw
Wall or flat objects
Interfaces
Repeater
Screw
Gin Pole
Interfaces
Repeater
Blocking
Hoop
Screw
Wall or flat objects
Interfaces
Screw
washer
Interfaces
Gin Pole
Blocking
Hoop
Repeater Repeater
1
W above models 1W above models mw-level models mw-level models
Wall-mounting Hoop Install Wall-mounting Hoop Install
4-4Accessories Installation
There will be built-in or external accessory module for different power/type of the series equipment. All the built-in accessory modules are installed in the factory, users
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
7
can use them directly. The installation of the external accessory modules can be completed in the project construction progress. The following table shows the modules configuration of all types of repeaters:
Module Name
10mW200 mW
1W200W
GPRS monitoring module
Built-in
Built-in
Optical Receiver Module
External
Built-in / External
Input Filter
External
Built-in / External
Output Filter
Built-in
Built-in / External
MMDS Receiver Down-conversion Module
External
Built-in / External
Input RF Delay Module
External
Built-in / External
4-5Cleaning and Maintenance
Before cleaning, please cut off power supply of the machine. If you use a damp cloth to clean the surface gently, make sure there is no liquid spilled inside the equipment during the cleaning, users can also use a hair dryer or vacuum cleaner to remove the dust inside the machine.
4-6Notes
(1) Please pay attention to equipment security and personal safety, cable must be correctly connected before switching on the machine.
(2)There is AC220V voltage power inside the cabinet. (3) If the repeater is switched on without antenna being connected, internal components
are likely to be damaged due to the RF reflection caused by open circuit. (4)Non-professionals can not arbitrarily move the cable, open the case, and move the
accessories inside cabinet, improper operation may damage the device because of strong electromagnetic field inside the equipment,
(5) The module shield block can be opened only when power supply is cut off, otherwise it will damage the components inside.
(6)The maintenance must be implemented by skilled technical personnel. The genuine parts must be used to replace damaged parts.
(7) Wear anti-static wrist strap to prevent components damage caused by static
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
8
discharge when plugging the circuit flapper or touch the other integrated circuit chips. (8)The equipment should be placed with good ventilation and heat dispersion. If it is
placed in open air, do not expose the equipment to burning sun or hailstones. Timely repair is necessary if there is a problem. Training is a must for maintenance staff. For the serious problems, the equipment should be sent back to factory for repair.
(9) Check periodically if the external connection is loose, corroded, or the cable is bitten by rat.
(10)AC voltage regulator should be installed in those areas with fluctuating voltage. (11)Seal the power supply port if it is not in use so as to prevent static electricity. (12)In operation status (connected to the power), only the designated staff can do the
maintenance work.
5System Functional Block Diagram
Input Filter
(optional)
LAN
DIGITAL
AGC
nS
Protection
circuit
Broadband
PA
POWER SUPPLY
MCUGPRS (optional)
A L C
Input reflection sampling
AC/DC
RF delay module
(optional)
Microwave
Down-
conversation
Module (optional)
Optical Receiver
Module
(optional)
Output
Filter
(Optional)
Pre-amplifier module
Power-amplifier module
Additional function modules
Waterproof
Cooling
System
220V/AC
DTV-UDWG series wideband digital TV repeaters can transmit one or more DTV signals to cover the buildings, basements, and signal shadow area effectively, etc. Repeater includes the main function modules and additional function modules.
The main function module of the repeater above 1 watts power types, consists of pre-amplifier module, power amplifier module, power module and water-proof air cooling systems (50 watts above types). Through continuous design optimization, CEKE has integrated the pre-amplifier module, power module and power amplifier module into one component, greatly increasing the reliability and stability of the equipments.
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
9
AC / DC Power Modules: located on the top side of repeater. The following table shows the equipment configuration and power specification of all models.
Pre-amplifier Module: located in the middle-upper of repeater (1W above models). It includes low-noise amplifier circuit, digital AGC control circuit, digital ALC temperature compensation circuit, rapid impact protection circuit, whole power supply adapter circuit, GPRS data remote monitoring and remote debugging circuits, output power control circuit, the noise power compensation circuit.
Power Amplifier Module: located in the middle-lower of repeater, it is a gain-fixed super-wideband power amplifier (200MHz above), the module contains the driver amplifier module and final amplifier circuit, input/reflect sampling circuit, temperature sampling and protection module and output filter (mw level models).
Water-proof Air Cooling System: 50 watts above serious products use the auxiliary air cooling system; it is located in the rear side of repeater. CEKE take full advantage of natural heat emission of the large area heat sink in thermal design, it avoids frequent start auxiliary cooling system, therefore enhance the stability of the equipment to the maximum. Our equipment adopted 2 sets of small water blowers with high reliability; such blower is not only waterproof but also can operate continuously in water.
6Function Features
DTV-UDWG series wide frequency band digital TV repeaters have the following main functions:
DTV-UDWG series products currently are one of the best equipments with advanced craftwork & technology in China, the products are water –proof and suitable for outdoor use. The cabinet looks simple and nice.
Supports all standard digital TV, mobile TV signal transmission and gap-filling. Supports single spectrum and wideband (multi-spectral) amplification. The Equipment can be customized into optical input type, microwave input type
and single frequency network delay adjustable type.
Nominal output power
10mW
20mW
50mW
100mW
200mW
1W
Power/Voltage
20W/12V
20W/12V
20W/12V
20W/12V
20W/12V
50W/24V
Nominal output power
5W
10W
20W
50W
100W
200W
Power/Voltage
100W/40V
100W/40V
400W/40V
400W/40V
600W/40V
1200W/40V
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
10
All internal debugging points inside DTV-UDWG series products are controlled via microcomputers, after being equipped with GPRS module, the equipments support the remote debugging. Equipment operating information, fault information could be remotely-monitored via internet or mobile SMS in real time.
The power amplifier use new generation LDMOS tube, it has the characteristics of high linearity, high efficiency, and more stable performance.
The equipments currently have the largest range (40dB, maximum 50dB) super large range AGC control circuit to ensure the stable output power.
DTV-UDWG series products have high-precise ALC compensation function; the equipment can maintain the stable operation even if external environment changes sharply.
DTV-UDWG series products use unique original noise power compensation program to avoid environmental noise on the signal AGC power in small-signal input circumstance.
DTV-UDWG series products use algorithm with combination of digital and analog to achieve the output power adjustable in a continuous wide range.
Models below 50 watts can provide the interfaces for external battery backup power and photovoltaic battery.
Protection against self-excitation: when self-excitation occurs, the repeater will be self-protect to avoid the damage to high-power amplifier.
DTV-UDWG original input power too-small protection. The repeater gain may reach the maximum when main transmitting station or fiber-optical link is shut down for maintenance, if in this status, the main transmitting station or fiber-optical link operate normally, this will cause large instantaneous power to damage the power amplifier. DTV-UDWG series products combined the power too-small protection and nS level shutdown circuit to effectively solve the impact of this effect.
The products are equipped with output power too-large protection and output reflection too-large protection. User can set the corresponding protection points via the control panel or remote control.
Super-fast impact protection for Pre-amplifier input overload power. Special rapid sampling and circuit shutdown can realize cut-off the link between pre-amplifier and power signal chain in nS level time period.
Power Protection, once the power value deviate from the user settings range, the system will stop working.
Temperature protection. Users can set the temperature to turn on or turn off the
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
11
auxiliary cooling system (50watts above equipments) and temperature at which equipment stops working according the actual environment. It thoroughly solves the equipment stability problems in high temperature environment.
Equipment password setting. It can effectively improve the safety broadcasting of the equipments outdoors.
Can be equipped with optical receiver module to make the optical signal directly accessible to repeater.
It can be equipped with the MMDS receiver module to make the equipment directly receive the microwave signal then converted to UHF signal for coverage.
DTV-UDWG unique RF delay input module. The RF signal delay module can avoid the multi-points cross-coverage interference in small-power multi-distribution networking (already have a national patent).
7Performance Indicators and Parameters
Repeater technical indicator
Item
Unit
Technical Indicators
Frequency range
MHz
460860
Frequency Stability3 month
Hz
When adopt internal reference sourceFrequency
stability1*10-7
When adopt external reference sourceFrequency
stability1*10
-10
RF Output Power Stability
after the filter
dB
±0.25
Bandwidth
MHz
Any bandwidth within 100MHZ
Number of carriers
6-8
Single carrier frequency
MHz
8
Input Level Range
dBm
-60-35RF reception),
0-30optical reception
Nominal output power
W
0.01200
Gain error
dB
±0.5
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
12
Gain adjustment range
dB
10 continuously adjustable
Automatic level control
dB
45
Out-of-band suppression
dBc
60
Output load reflection loss
With bandwidth of 8MHz
dB
Proper working:≥21
Allowed working:≥16
Output shoulder
(single spectrum±4.2MHz)
dB
-38dBsingle spectrum 8MHZ
In-band flatness
single spectrum
dB
±0.5fc±3.756MHz
Transmission Delay
μ s
5
Noise Figure
dB
5Max.Gain
Stray radiation
dBm
-365MHz~1GHz, Outside the spectrum
template
Spectrum feature
--
Comply with GY/T 220.1—2006 5.9.3 spectrum
requirement
Output Characteristic Impedance
50
Input/output VSWR
1.5
Power supply
--
AC220V ±10%45Hz60Hz
AC60V ±10%45Hz60Hz
Dimension
mm
187*120*45 (≤200mw
315*305*1891W
465*305*1895W10W
500*405*23020W 50W100W
650*480*275200W
Input interface
--
SMA -K (50Ω ) (≤200mw
1/2 N –K (50Ω )10W200W
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
13
Output interface
--
SMA-K (50Ω ) (≤200mw
1/2 N –K(50Ω )10W200W
Monitoring Interface
--
SMA -K(50Ω )
Monitoring
--
Remote monitoring via text message
Operating temperature
-25℃~+55
Relative humidity
--
95%
Operating Altitude
m
5000
8Interface Introduction
DTV-UDWG series repeaters have perfect input and output interfaces. There are position marks for corresponding interfaces in front of the equipment panel. The interfaces including: RF input/output interfaces, RS232 Interface (1W above), GPRS antenna connector, power connector, optical input interface, SIM card insert interface (1W above built-in), setting button (1W above built-in.)
1W above model power connector
mW level model power connector
1---L
2---G
3---N
1---L
2---N
3---L
4---N
5---G
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
14
9Operating Menu Description
DTV-UDWG Series Repeater is equipped with screen and button. The device has four cursor keys, a OK button and a cancel button. Using them to browse and operate the menu system for completing system configuration.
UP key: in menu browse status, move the cursor up;In enumeration parameter
editing status, rotate parameters value; in numeric parameter editing status, increase the parameter value.
DOWN key: in menu browse status, move the cursor down;In enumeration
parameter editing status, rotate parameters value; in numeric parameter editing status, decrease the parameter value.
LEFT key: in menu browse status, move the cursor left; In numeric parameter
editing status, move the cursor left.
RIGHT key: in menu browse status, move the cursor right;In numeric parameter
editing status, move the cursor right.
ESC key: in menu browse status, move back to previous menu;In parameter editing
status, move to the current menu item.
Enter Key: In menu browse status enter the sub menu, in the parameter editing
status, save the results of parameters changes. Equipment operating/control panel object is a tree-shaped functional menu system. The
tree-shaped diagram shown as follows:
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
15
9.1 Repeater 3.3 Program Client Interface Introduction:
1.Information
Equipment
information
Info(start-up informtion)
GUILIN SIQI REPEATER
2.FORD Pow Output power
3.REF Pow Reflection
power
4.ATT ATT
attenuation
value
6.TEMP
Temperature
2.alarm
Alarm
information
3.setup
System setting
7.PA status Power
Amplifier
status
8.FAN status
1.AGC set
Power setting
1.PRE-AMP RF in
Preamplifier
input
2.PRE-AMP status
Preamplifier
status
3.TEMP
temperature
4.FORD Pow
Output power
5.REF Pow
Reflection power
6.MAIN DC power supply
Power voltage
2.ATG set
3.exturn ATT Additional
attenuation value
4.MAX input power
Preamplifier
maximum power
5.MAX FORD Power
Maximum output
power
6.MAX REF Power
Maximum
reflection power
7.MAX DC Power
Power supply
upper limit
Set output power
0~176
input signal corresponding to attenuation values Automatic(default)
-15~-25dB attenuate 30dB
-25~-35dB attenuate 20dB
-35~-45dB attenuate 10dB
-45dB below attenuate 0dB The above attenuation value applies to -15~-60 dB RF signal strength, optical fiber received signal strength should plus 30 dB based on RF signal strength.
Set preamplifier output
maximum protection
point (general 2.5 V)
Set maximum output power
protection point(maximum
add 40%)
Set maximum reflection
power protection point
maximum add 4 times)
Set main power supply
voltage upper limit
protection point
9.A_FWD
Output power
Detection
voltage
7.first alarm
8.Second alarm
9.Thrid alarm
Password
Enter passworddefault 0000
Temperature
compensationdefault
open enable
8.MIN DC Power
Power supply
lower limit
Set main power supply
voltage lower limit
protection point
9.Password set
Password setting
Navigation key for setting
password
ENT key for confirmation
4.System set
GPRS setting
Pass word
Enter passworddefault
0000
1.id
Equipment ID
2.master id
3.version:3.31
Version No.
4.model00
Mode
Mobile number
6.SMS center number
7.server center number
8.other number
9.server ip
Service IP add
10.server port
11.report inter
00H05M
Report time
12.gprs enable
GPRS switch
1.AGC state AGC ready
state
5.AGC
AGC value
10.DC power
Power supply
voltage
Remarks: There are two repeater programs: 3.3(short message module) and 3.52(TCP data module). They varies only on 4.system set, others are the same. Please check version number in 4.system set-GPRS setting-3.version 3.3.
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
16
Detailed description: 3-1 below is a sub of main items, such as 3-1, 1(AGC set) is the sub of 3(set up system setting).
1 .Equipment information
Check the real-time status of repeater, only view but can not be modified, it refreshes every 0.3 seconds. 1-1 AGC ready status. The machine will detect the strength of input signal and adjust the attenuation value automatically after turning on .READY will be shown after 5 seconds, if there is no alarm, it can work properly. If it shows NOT READY, and without any other alarms, please reviews 1-4, the input signal might be too weak or too strong. Please restart the repeater if signal strength changes. 1-2 FOR D POW Current output power display Unit: W 1-3 REF POW Current reflection power display Unit: W
1-4 ATT Corresponding to the AGC value in 1-5, is the value of current operation. It will output power if AGC equals to ATT. If ATT value is higher than
AGC, it shows the input signal is too strong or self excited, the device will be protected.( By temperature compensation effect of 3-2, ATG STE, it is normal that ATT is 10 degree higher than AGC,.) If ATT value is lower than AGC value, the input signal is too weak; it can not output full power. The item is used to determine the received signal strength, please check other alarm items and status when abnormal.
1-5.AGC is same to 3-1 AGC SET, it is used for comparing with ATT(1-4). Set the AGC value manually. 1-6.TEMP Equipment current temperature. The fan controls the temperature automatically; it operates when temperature reaches 45°C, stops rotation at 40°C, automatically stops operation at 70°C. Unit: °C
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
17
1-7. PA status Amplifier current operation status. ON or OFF. 1-8.FAN statue Fan current status: ON or OFF 1-9.A-FWD The detection power of amplifier power detection point, is a specific voltage value of output power display item shown in 1-2,and display a same monitoring point with output power shown in1-2.Unit: V 1-10.DC POWER Output voltage of power supply module. Unit: V Repeater Under 1W model is 27V, over 1W is 39 V
2 . Alarm
Check the alarm information of current repeater. Only view but can not be modified, it refreshes every 0.3 seconds. If the repeater can not operate normally, please review this alarm information to determine the problem and investigate it one by one until the repeater operates normally. 2-1.PRE-AMP RF IN Pre- amplifier RF input status Displaying OK/P-A RFIN LARGE, the input signal is too strong ; A RFIN SAMLL, the input signal is too weak. Please review 1-4 &1-5.The too strong input signal may lead to self-excitation, and reduce the strength of signal or isolation between antennas. The too weak signal is caused by input feeder off or antennas are not aligned to the signal resource, you can adjust the antenna angle and check the input feeder. 2-2.PRE-AMP status Display ON or OFF. It will display OFF when other items are protected. 2-3.TEMP temperature display OK or higher. PRE-AMP output will be cut off when temperature reaches 70°C. 2-4.FORD POW Output power Displaying OK or P-A R OUT LARGE output power is too large. This alarm is caused by too large output power or 3-5 low protection point setting. You can reduce AGC value (3-1) or increase the max-output power protection
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
18
point (3-5). 2-5.REF POW Reflection power Displaying OK or REF OUT LARGE reflection output is too large. This alarm is caused by loose output feeder and antenna or low reflection power protection point setting 3-6. You can check the antenna or feeder, or increase 3-6 the max-reflection power protection point value. 2-6.MAIN DC power Power supply. This alarm is caused by power supply test voltage is too high or too low, and inappropriate setting of too large and too small voltage .You can check the current display voltage or test the power supply output voltage with multimeter (1-5), adjust the voltage up-limited protection point and voltage up-limited protection point (3-8)appropriately. 2-7.FIRST ALARM The first alarm. Record the latest alarm reason. 2-8.SECOND ALARM The second alarm 2-9.THRED ALARM The third alarm
3 . SETUP system settings
Revise the setting of repeater power.protection point etc. Arrow key for setting, ENT for confirmation. PASSWORD Enter password, default: 0000 3-1.AGC SET Power set-up, adjust the output power of repeater. Program version 3.3 will set the AGC to highest value in factory, hence, cannot continue to increase; the device is different from each other. It will output full power when reaching the highest level. It is not likely to happen that the equipment output power exceed the standard output power.
3-2.ATG STE Temperature compensation. Enable (open) and disable (close). Default open. Because of the equipment linearity, after temperature rises, power will decrease by 5%. This value can guarantee that nominal power can work properly when
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
19
temperature rises.
3-3.EXTURN ATT Extra-attenuation values. Input corresponding attenuation value :
Automatic (default) The equipment will be burned due to incorrect settings
Input signal: -15~-25dB; Attenuation: 30 dB Input signal: -25~-35dB; Attenuation: 20 dB Input signal: -35~-45dB; Attenuation: 10dB Input signal: -45dB; Attenuation: 0dB
The above attenuation value applies to -15~-60 dB RF signal strength, optical fiber received signal strength should plus 30 dB based on RF signal strength.
This item is default as AUTO, no need to set. If it is set at a fixed attenuation, you have to test the strength of input signal according to list above and check 1-4, the same illustration with 1-4. 3-4.MAX input power Preamplifier output too large protection point, unit: V. This is protection voltage (default value: 2.5V) of preamp when signal suddenly turn stronger or produce self-excitation, no need to set and can not exceed 3.5V, or amplifier will be burned down because of self-excitation.
3-5.MAX FORD POWER Max- output power protection point. Corresponding to output power display (1-1), and then adjust the max- output power protection point, the general maximum add 40%, for example, a 50 W repeater, the protection point is 70W,please increase the protection point to 85 W if the display power fluctuations lead to frequent protection.
3-6 MAX RER POWER Maximum reflection protection point Corresponding to reflection power display 1-2 .Generally it is the 4 times of reflection power display
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
20
value. For example, the reflection rate of 50W machine is at 5W, the protection point will be set at 20W.This value could be increased if there is strong reflection after checking the antenna or feeder work properly.
3-7.MAX DC POWER Power supply voltage upper protection point. If power supply display value surpasses the voltage upper protection point, it will come into protection. The general setting is display value increase by 4V. If it shows 39V, the protection point setting is 43V.
3-8.MIN DC POWER Power supply voltage lower protection point. If the power supply voltage display value shown in 1-5 is lower than power supply lower limit protection point, it will come into protection; Generally the display value decreased by 7V. If it shows 39V, the protection value setting is 32V.
3-9.PASSWORD SET Password setting This is the entry password for item 3 SETUP. The default password is 0000. Arrow keys for resetting the password and ENTER for confirmation.
4SYSTEM SET GPRS GPRS setting
If the repeater is equipped with GPRS module and corresponding antenna, then he can use the mobile phone SMS function to have remote monitoring of DTV-UDWG series repeater. The usage is as follows: For example, using our own cell phone to edit X300X with our own phone number, then sending this message to repeater cell phone number.
Means using 137XXXX3786 cell phone to send a message ‘X300X137XXXX3786’ to
mobile phone number 139XXXX2007 of the repeater SIM card, and we will receive a message of repeater status. The repeater will enable the 4:.SYSTEN SET –12.GPRS ENBBLEGPRS switch,no more settings are needed, Message will be received as
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
21
below: Id0010AGC is ready; Ford:100.0w; REF:001.0w; ATT:100; AGC:100; Temp:40C; DC:38V; PA:ON ; FAN:ON ;AFWD:1V; last alarmthe alarm information is as follows: 0: "no alarm" Normal 1: "P-A RF in large" Preamplifier signal input is too large. 2: "P-A RF in small" Preamplifier input is too small. 3: "P-A status off" Preamplifier closed. 4: "Temp high" Temperature is too high. 5: "FORD Pow alarm” Transmitting power is too high. 6: "REF Pow large" Reflection power is too high. 7: "MAIN DC alarm" Abnormal voltage alarm 1ID0010 Equipment No. Refer to 4-1 ID
2 AGC is ready AGC status NOT READY or READY
3FORD 100.0W Current transmission power Unit: W.
4REF001.0W Current reflection power Unit: W.
5ATT100 Current AGC value, refer to AGC value in 4-1
6.AGC:100 Manually set-up AGC powerrefer to AGC value in 4-1.
7TEMP40C Current machine temperature Unit: °C
8、DC:38V Current power supply voltage 27V for 1W,39V for machine
over 1W.
9PAON Current amplifier operation status ON or OFF
10FANON Current fan open status ON or OFF
11、AFWD:1V Circuit voltage of amplifier power detection should be the
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
22
specific voltage value matched with output power shown above in 1-2. Unit: V
Notes:
Please switch off the equipment when changing the SIM card. The equipment can be
turn on when SIM card is correctly inserted and the cables are well connected. If you can not make calls or receive text messages, please check the connection of the socket in GPRS module, possible overdue GSM card bill, or the loose connection between antenna and other cables. If you can make calls but can not receive the messages, which might indicate weak signal and strong disturbance, please check if the antenna and feeder of GPRS are in near distance with output port and feeder of the repeater, which should be set far from repeater antenna. If the GPRS doesnt work after being se up by the steps above, or the signal is too weak and interference is too strong, an extension cable with length of 10 meters should be added to the output interface of GPRS module. Try to keep the GSM antenna away from repeater transmitting antenna. Use waterproof tape to cover the connectors. If the signal is normal, there is not need to add 10 meters extension cables, which will cause attenuation to GSM signal. If there is no GSM mobile signal nearby, GPRS function is not available.
It takes about 2 minutes for the GPRS to get started. Please check short message later on. It is normal that the monitor module may fail to work properly in 10 seconds while repeater is sending message. It is internal protection mechanism. Everything will be operated properly when the message is done.
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
23
9.2 Repeater 3.52 Program Client Interface Introduction:
1.Information
Equipment
information
Info(start-up informtion)
GUILIN SIQI REPEATER
2.FORD Pow Output power
3.REF Pow Reflection
power
4.ATT ATT
attenuation
value
6.TEMP
Temperature
2.alarm
Alarm
information
3.setup
System setting
7.PA status Power
Amplifier
status
8.FAN status
1.AGC set
Power setting
1.PRE-AMP RF in
Preamplifier
input
2.PRE-AMP status
Preamplifier
status
3.TEMP
temperature
4.FORD Pow
Output power
5.REF Pow
Reflection power
6.MAIN DC power supply
Power voltage
2.ATG set
3.exturn ATT Additional
attenuation value
4.MAX input power
Preamplifier
maximum power
5.MAX FORD Power
Maximum output
power
6.MAX REF Power
Maximum
reflection power
7.MAX DC Power
Power supply
upper limit
Set output power
0~176
input signal corresponding to attenuation values Automatic(default)
-15~-25dB attenuate 30dB
-25~-35dB attenuate 20dB
-35~-45dB attenuate 10dB
-45dB below attenuate 0dB The above attenuation value applies to -15~-60 dB RF signal strength, optical fiber received signal strength should plus 30 dB based on RF signal strength.
Set preamplifier output
maximum protection point (general 2.5 V)
Set maximum output power
protection point(maximum
add 40%)
Set maximum reflection
power protection point
maximum add 4 times)
Set main power supply
voltage upper limit
protection point
9.A_FWD
Output power
Detection
voltage
7.first alarm
8.Second alarm
9.Thrid alarm
Password
Enter passworddefault 0000
Temperature
compensationdefault
open enable
8.MIN DC Power
Power supply
lower limit
Set main power supply
voltage lower limit
protection point
9.Password set
Password setting
Navigation key for setting
password
ENT key for confirmation
4.System set
GPRS setting
Pass word
Enter passworddefault
0000
1.id
Equipment ID
2.version:3.52 Version No.
3.Model:00.
Mode
4.GPRS:Enable
5.Server IP
Server IP ADD:
222.052.140.130
6.Server Port:
Server port 7300
7.Report inter 00H10M
Report time
1.AGC state AGC ready
state
5.AGC
AGC value
10.DC power
Power supply
voltage
Remarks: There are two repeater programs: 3.3(short message module) and 3.52(TCP data module). They vary only on 4.system set, others are the same. Please check version number in 4.system set-GPRS setting-2.version 3.52.
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
24
Description: First three items are the same for version 3.3 and 3.52. Settings are same for 1.Information 2.alarm 3.setup As for detailed description of first three items of version 3.52, please refer version 3.3. Please note they vary on 4.
4SYSTEM SET GPRS GPRS setting
If the repeater is equipped with GPRS module and corresponding antenna, the user can use computer to remote-control DTV-UDWG series repeater.
Please switch off the equipment when changing the SIM card.
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
25
GPRS module is installed as shown in the picture below. Twist off the 4 screws around the GPRS module and put the SIM card inside to fit the card slot. The orange indicator light will turn on two minutes after being switching on. If the ACT indicator light doesn’t show on, please check possible overdue GSM card bill, or the loose connection between antenna and other cables. Or there might be weak signal and strong disturbance, please check if the antenna and feeder of GPRS are in near distance with output port and feeder of the repeater, which should be set far from repeater antenna. If the GPRS doesnt work after being se up by the steps above, or the signal is too weak and interference is too strong, an extension cable with length of 10 meters should be added to the output interface of GPRS module. Try to keep the GSM antenna away from repeater transmitting antenna. Use waterproof tape to cover the connectors. If the signal is normal, there is not need to add 10 meters extension cables, which will cause attenuation to GSM signal. If there is no GSM mobile signal nearby, GPRS function is not available. It takes about 1 minute for the GPRS to get started. Please wait patiently. Please call you mobile phone service provider to apply for GPRS service, 30M is enough. GPRS setting at repeater end: GPRS has been set in the factory, and there is not need to modify. If there is accidental modification, you can set it up as below:
1. ID repeater ID card. First four numbers shown in repeater tag. For example, repeater tag is NO. SQ12050014R010, then ID is 0014. 2VERSION: 3.52 check the program version of repeater, can not be modified. 3MODEL mode default00, no need to set up.
4GPRS ENABLE GPRS switch. Remote control comes into use only when the GPRS enable. 5SERVER IP Service IP address. Set up IP address for remote control.
Default: 222.052.140.130, no need to modify.
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
26
6SERVER PORT Service port. Default: 7300, no need to modify.
7REPORT INTERV set the report time as ten minutes for sending data from repeater to remote server on regular basis. It is normal monitoring module inside the repeater can not be operated for seconds when the repeater remote control system is checking the equipment information. It could be operated after the checking is finished.
Inquiry method: use any computes with Internet connection, open GOOGLE browser, key in the website for remote control software in the address bar. Input the user ID and password provided by us, you can check it after logging in. Check the repeater information by clicking corresponding equipment in the map interface. User ID and password are private information. Please ask for them from the customer service representative. They should be in charge of designated staff.
We will provide appropriate account number and password after the customer
adding remote centralized monitor module to the equipment, if password lost or
incorrect; please contact our customer service and provide identification
authentication to obtain password or modify it. The account and password are
confidential information, please manage by hand.
Centralized monitor visit website: http://glsqjk.com
Any query, please contact our customer service.
Tel: +86 773 2120 299
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
27
10Fault Description
According to the general condition of the equipments, the common faults and troubleshooting methods are shown in below table for your reference:
1. Preamplifier output signal is too large
2. Equipment self-excited
Preamp input signal is too
small
1. Equipment start status
2. Caused by other faults
Equipment internal
temperature is too high
Output power is too large
Reflection power is too
large
Main power supply failure
PRE-AMP RF out
Preamplifier RF
output
PRE-AMP RF in
Preamplifier RF input
PRE-AMP status
Preamplifier status
TEMP
Temperature
FORD Pow
Output power
REF Pow
Reflection Power
MAIN DC power
Power Supplier
Voltage
Reduce the AGC value; reduce preamplifier input power;
check the adequacy of the antenna isolation, whether
self-excited or not; appropriate adjust protection points.
Reorient the receiving antenna,
adjust input signal to the normal and safe acceptable
range
Wait for equipment start-up; turn the power off and then
restart equipment; check other fault information
Check whether the ambient temperature exceeds the
normal equipment operating temperature; check the fan
is operating well or not; check ventilation; replace the corresponding device; adjust fan control temperature.
Reduce the output power, check the antenna isolation is
adequate, whether there is self-excited; appropriate
adjust protection points.
Check the output cable connected correctly, check the
antenna VSWR is sufficient; appropriate adjust
protection points.
Check the power supply voltage; adjust setting scope of
protection; replace the corresponding module
Fault ReasonFault Phenomenon Treatment
Final power amplifier failure
No RF output, But AGC value normal
Check final power amplifier power supply and final power
amplifier module, replacing the corresponding module
Off groundChassis leakage Ground connected
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China. Tel: +86 773 2120 156 Fax: +86 773 2120 299 Emailglsq@glsq.com Web: www.glsq.com
28
11Warranty Card
Warranty Card
Thank you and your company to buy our products, please fill in the following contents once purchase the equipments and keep this card, so that we can provide comprehensive after-sales service for you and your company.
Product Name / Model: Product Serial No.: Origin of goods: Sales Company Name: Sales Company Address: Sales Company Telephone / Zip Code: Invoice No.: Sales Date: Customer Name: Sales Telephone: Customer Address / Zip Code: Warranty Company Name: Telephone No.: Warranty Company Address / Zip Code: Warranty records:
Seal:
Manufacturer: Guilin CEKE Communication Equipment Co., Ltd.
Address: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004,
P.R.China.
Telephone: +86 773 2120 156 Fax: Fax: +86 773 2120 299
Loading...