Cecilware HWD2 Operation Manual

Operation Manual
NI60A 04-2002
The Hot Water Dispenser is shipped, from the factory, with the Heater Switch in the "OFF" position. DO NOT turn the heater switch ON until the unit is primed with water. The heater switch is located at the lower back of the unit.
WATER INLET CONNECTION :
The Hot Water Dispenser is to be installed to comply with all applicable Federal, State and Local plumbing codes. Furthermore, a quick disconnect or enough extra coiled tubing, (at least 2 times the depth of the machine) should be installed, so that the unit can be moved for proper cleaning underneath. It is recommended that an approved back flow prevention device, such as a double check valve, and a shut-off valve should be installed between the Hot Water Dispenser and incoming water supply.
START - UP PROCEDURE: CAUTION: MAKE SURE THE HEATER SWITCH, LOCATED AT THE LOWER BACK OF THE UNIT, IS IN THE OFF POSITION.
1. Connect a ¼" diameter copper waterline to the ¼" flare water inlet.
2. Open the water shut-off valve and check connections for leaks. DO NOT over-tighten.
3. Plug in the Hot Water Dispenser into a dedicated power supply outlet.
4. Activate the Power Switch (front of unit) the water tank will begin to fill, providing the water connection is open. The tank will fill in approximately 3-4 minutes.
5. After the tank has filled, activate the Heater Switch (toggle up, lower back of unit). Depending on the model selected, it will take approximately 15-25 minutes for the water to heat to operating temperature.
NOTE: This procedure is for initial start - up only; however, steps 4 and 5 must be repeated should the tank be completely drained. Steps 1 thru 5 must be repeated should the machine be drained, disconnected and reinstalled in a new location.
THERMOSTAT ADJUSTMENT:
Remove the two (2) screws from the top cover and remove cover. The thermostat, will be visible. First, adjust the
thermostat by turning the thermostat knob either clockwise to raise the temperature, or counter clockwise to lower the temperature. If further adjustment is required, remove knob, turn the adjustment screw, located in the center of the thermostat shaft, counter clockwise to increase the temperature and clockwise to decrease the temperature.
Unit should be set to approximately 203°F.
WARNING: Always disconnect HWD from power supply before repairing or replacing any internal components.
DOES NOT FILL
WATER CONTINUES TO FLOW FROM OVERFLOW
COLD WATER
WATER BOILS CONTINUOUSLY
1. Water supply off
2. Line cord not plugged in
3. Power switch off
4. Circuit breaker tripped
5. Power switch inoperative
6. Solenoid valve inoperative
7. Level control inoperative
1. Leaking solenoid valve
2. Level probe dirty
1. Heater switch in OFF position
2. Thermostat in OFF position
3. Thermostat defective
4. High limit switch defective
5. Heater element defective
6. Loose electrical connection(s)
1. Thermostat out of calibration
2. Thermostat defective
Page -1-
Turn water supply on Plug in line cord Turn power switch on Reset breaker Replace power switch Replace solenoid Replace level control
Replace solenoid Clean or replace probe
Turn heater ON Turn thermostat ON Replace thermostat Replace high limit switch Replace heater element Tighten all loose connections
Adjust thermostat as listed above Replace thermostat
Hot Water Dispenser - HWD2
Electrical Specifications
Tomlinson faucet Manual dispense
MODEL NO WATTSVOLTS
PHASE
& CYCLES
HWD2
Export units add "X" to Model No. Specify Voltage and type of line cord required.
1700120 1 PH. 50/60 Hz 3000240 1 PH. 50/60 Hz
Water Connection
Water pressure: 20 - 90 PSI (69 - 621 KPA) Supplied with ¼ OD male flare fitting
Operational
MODEL NO
HWD2
VOLTS
120 (1.7 KW) 240 (3.0 KW)
INITIAL
HEAT-UP TIME
20-25 Min 15-20 Min
BURST
CAPACITY
1.5 Gals
Heat-up time and Dispense rate based on Inlet water temperature at 68°F and Dispense water temperature range 165°F to 200°F
RECOVERY GALLONS
POWER CORD
(included)
P5-15 P6-15
PER HOUR
10-15 Min 4.5
5-10 Min 8.02.0 Gals
9.9
RECEPTACLE
R5-15 R6-15
TANK
CAPACITY
2.8 Gal
7.9
DISPENSE FAUCET
OVERFLOW TUBE
DRIP TRAY
1.0
INLET
VALVE
24.0
15.9
POWER CORD
HEATER SWITCH
15.4
Page -2-
1 2
3 4
20 19
5
6 7
18
8
23
9
10
17
11
16
12 15
13
1 2 3 4
6 7 8
9 10 11 12 L462A
FAUCET FAUCET SHANK POWER SWITCH POWER LIGHT - RED HEATER LIGHT - AMBER5 SILICONE SEAL 12mm (0.466 I.D.) LEVEL CONTROL PROBE HI-LIMIT 220° CUTOUT HEATER ELEMENT, 120V 1700W HEATER ELEMENT, 240V 3000W THERMOSTAT WATER INLET VALVE, 120V
80234 77203 L069A C165A C260A M461A K402Q L573A G267A G266A L532A
14
21 22
13 14 15 16 17 18 19 20 21 22 22 M857A
WATER INLET VALVE, 240V COIL STRAIN RELIEF LINE CORD, 120V 15A LINE CORD, 240V 15A HEATER SWITCH WATER TANK, HWD2 WATER LEVEL CONTROL, 120V WATER LEVEL CONTROL, 240V DRIP TRAY PAN DRIP TRAY GRILL SILICONE HOSE 3/8ID x 16" LG
C223A B012A C032A C770A L069A 40799 L398A L599A 75014 75015
Page -3-
Hot Water Dispenser - HWD3
Electrical Specifications
Tomlinson faucet Manual dispense
MODEL NO WATTSVOLTS PHASE
& CYCLES
HWD3
Export units add "X" to Model No. Specify Voltage and type of line cord required.
1700120 1 PH. 50/60 Hz 3000240 1 PH. 50/60 Hz
Water Connection
Water pressure: 20 - 90 PSI (69 - 621 KPA) Supplied with ¼ OD male flare fitting
Operational
MODEL NO
VOLTS
INITIAL
HEAT-UP TIME
HWD3
Heat-up time and Dispense rate based on Inlet water temperature at 68°F and Dispense water temperature range 165°F to 200°F
120 (1.7 KW) 240 (3.0 KW)
20-25 Min 15-20 Min
BURST
CAPACITY
1.5 Gals
RECOVERY
POWER CORD
(included)
P5-15 P6-15
GALLONS
PER HOUR
10-15 Min 4.5
5-10 Min 8.02.0 Gals
RECEPTACLE
R5-15 R6-15
TANK
CAPACITY
2.8 Gal
24.3
IMPORTANT
- BEFORE REMOVING TOP PANEL ­DISCONNECT POWER
REMOVE BOTTOM PANEL
AND DRAIN TANK
1.3
9.8
7.0
Page -4-
23.5
12.09.3