HOT WATER DISPENSER
HWD—2 240V
For Preparing:
Tea
Instant Coffee
Soups
Hot Cereals
Cocoa
Pudding
Gelatins
SPECIFICATIONS
Electrical:
HWD—1 1750 Watts @ 120VAC, 50/60 HZ
Supplied with a 15A—120V grd. Plug.
HWD—2 2750 Watts @ 240V, 1 PH, 50/60 HZ
Water Connections:
1/4 O.D Copper Tube for Installations
Less than 15 ft.
3/8 O.D. Copper Tube for Distances
exceeding 15 ft.
Min. Water Pressure: 20 Ibs.
CECILWARE CORPORATION
GENERAL OFFICE & FACTORY
43-05 20th Ave., Long Island City, NY 11105
(718) 932-1414 142034/99
INSTALLATION:
Solenoid valve inoperative
Clean or replace ball float
Loose electrical connections
The unit is shipped with the thermostat in the "OFF" position. CAUTION, do not turn thermostat on before unit is primed with
water.
1. Remove two screws from top cover and remove cover.
2. Flush inlet water line thoroughly before connecting.
If pipe sealant is necessary, Teflon tape is recommended.
3. Connect ¼” O.D. tubing to ¼” flare fitting located at rear of unit. A shutoff valve in the water supply is advisable.
4. Turn on water and check line and fittings for leaks.
5. Examine the electrical data label attached to the machine and plug the power cord into the appropriate power supply.
6. Depress the power switch of the machine to the "ON" position and the water will automatically enter the tank. It will take
approximately 2 1/2 minutes to fill the tank.
7. Turn the thermostat knob to its maximum clockwise position, replace cover and wait approximately 14-25 minutes
for the water to heat.
Note: These instructions are for initial priming only and need not be repeated for normal operation.
PRODUCTION CAPACITY
*Initial Heat-Up Time
Burst Capacity
Recovery
Gallons per HR.
*Inlet Water Temp. at 68° F
HWD—1 HWD—2
25 minutes
189oz.
19 minutes
4.6
14 minutes
189oz.
10 minutes
8.8
THERMOSTAT ADJUSTMENTS:
Remove the two screws (43) from the top cover and remove cover (Fig. 7). The thermostat will be visible (Fig. 8). First try to adjust
temperature by rotating thermostat knob clockwise to raise temperature, counter-clockwise to lower temperature. If further
adjustment is needed, remove knob exposing shaft with adjustment screw in center of shaft. Turn the adjustment screw counterclockwise to raise temperature and clockwise to lower temperature. Unit should be set at 205F or just below boiling. To prevent the
adjustment screw from turning after the adjustment is completed, apply nail polish or Glyptol to the screw.
TROUBLESHOOTING GUIDE:
Warning: Unplug the dispenser power cord before repairing or replacing any internal components of unit.
Trouble Probable Cause Remedy
No water from
Water continues 1. Leaking solenoid valve 1. Repair or replace valve
to flow from
1. Line cord not plugged in
3. Power switch inoperative
5. Water supply off
7. Reed switch inoperative
8. Relay inoperative 8. Replace relay
2. Reed switch inoperative
1. Plug in line cord
3. Replace switch
5. Turn on water supply
7. Replace Reed switch
2. Replace Reed switch
Cold water 1. Thermostat in "OFF" position 1. Turn thermostat "ON"
Water boils 1. Thermostat out of adjustment 1. Follow thermostat
continuously
contains water
2. Thermostat inoperative
2. Thermostat inoperative 2. Replace thermostat
2. Replace thermostat
connections
adjustment procedure