ELECTRIC CHEESEMELTERS
For Counter, Pass-Thru and Wall Mount
Installations.
OPERATION MANUAL
CM -24 CM -36
CM-24M Metal Sheath Elements CM-36M Metal Sheath Elements
CM-24Q Quartz Tube Elements CM-36Q Quartz Tube Elements
ELECTRICAL DATA ELECTRICAL DATA
1.8 KW 120 Volts single phase 50/60 Hertz 3.6 KW 240 Volts single phase 50/60 Hertz
DIMENSIONS DIMENSIONS
Width — 24" Width — 36"
Depth 13" Depth 13"
Height 15" Height 15"
(add 4" for NSF legs) (add 4" for NSF legs)
3.6 KW 208 Volts single phase 50/60 Hertz
CECILWARE CORPORATION
43-05 20th Avenue, Long Island City, N.Y. 11105 • 718-932-1414
531 Southern Blvd., West Palm Beach, Fla. 33405 - 561-655-9696
N239F - 11/96
INSTALLATION INSTRUCTIONS for...
CM-24 and CM -36 Counter Cheesemelters. Select a suitable location for your cheesemelter and adjust the
leveling legs on the bottom of the unit to level it and prevent rocking.
CM-24 and CM -36-Pass-thru units — Remove the outer and inner back panels. Adjust the leveling legs.
CM-24 and CM -36 — Wall mounted units — Remove the outer back panel and mount the wall brackets to the
back of the unit using the same screws, refer to ILL. 1 on page 3. position the Cheesemelter on the wall and
mark the four holes through the mounting brackets on the wall. Use 5/16 diameter toggle bolts 2" long or an
equivalent fastener to mount the unit to the wall.
ELECTRICAL — (See ILL.2. page 4)
For CM-36 remove the cover from the field wiring compartment located on the bottom of the Cheesemelter.
Use a suitable conduit fitting and connect two #10 wires from the power source to terminal L1 and L2 of the
terminal block and a ground wire to the grounding lug marked GND.
For CM -24 provide a suitable 120V — 15A wall outlet.
OPERATION
Apply power to the unit and turn the infinite switch knob(s) to the high position. Allow a few minutes for the
elements) to reach operating temperature. Place the wire rack at the desired level and the cheesemelter Is
ready to operate. Adjust the infinite knob(s) for the proper heat and adjust the rack for the type of food you are
preparing.
MAINTENANCE
Very little maintenance is required on this unit. Use a mild detergent on the stainless exterior and a com-
mercial cleaner for the oven compartment.
Service Procedures —
FOR QUALIFIED SERVICE PERSONNEL ONLY
Problem: Element(s) do not heat when control(s) are turned on.
Possible Cause: Loss of power to cheesemelter.
Remedy: Check fuses or reset circuit breakers from power source.
Problem: One or more element(s) of cheesemelter fail to heat up with Infinite switch and pilot on.
Possible Cause: Element is burned out and should be replaced. Replace as follows: (See ILL. 1)
A — Metal Sheath Elements.
1. Turn off power to cheesemelter.
2. Remove one screw from each element bracket and rotate bracket (11) to clear element.
3. Remove the two screws holding the element to the side panel and withdraw the element. Remove the
two wires from the element being careful that the wires do not fall behind the panel.
4. Replace the element in the reverse order of removal.
B — Quartz Tube Element.
1. Remove quartz element bracket mounting screws from one side of the cheesemelter.
2. Lower the bracket (9) to clear the quartz elements and withdraw the guard rods (10) from the other
bracket.
3. Remove the other bracket.
2