Neutral and Ground Wires # 14 AWG min.
Note: Field wiring must be suitable for 75° C. Use copper wire only for power supply connections.
GROUNDING: ON ALL URNS, CONNECT A GROUND WIRE TO GROUNDING LUG TO COMPLY WITH
LOCAL ELECTRICAL CODES (14 AWG MIN. 75° C)
(2) 10 AWG + GND
(2) 10 AWG + GND
(2) 8 AWG + GND
(2) 6 AWG + GND
Wire Size
-
3 Phase
(3) 10 AWG + GND
-
(3) 10 AWG + GND
(3) 8 AWG + GND
(3) 8 AWG + GND
WARNING LABEL NN85A
NN85A
29.1
19.3
BREW
POWER
STOP
OFF
1
2
CAUTION
HOT SURFACES
BLEND
10
9
8
7
6
5
4
3
3.5
29.1
19.3
4.0
NN10A
10.1
2.5
14.016.05.4
POWER
STOP
BREW
BLEND
10
9
8
OFF
7
6
5
1
4
2
3
CAUTION
HOT SURFACES
3.5
4.0
28.0
5.4
NN10A
10.1
2.5
14.0
31.2
21.2
4.0
POWER
STOP
BREW1/2 BREW
BLEND
10
9
OFF
1
4
2
3
CAUTION
HOT SURFACES
8
7
6
5
3.5
NN10A
10.1
2.5
34.5
23.4
4.0
32.05.4
BREW
POWER
STOP
OFF
1
2
CAUTION
HOT SURFACES
16.0
BLEND
10
9
8
7
6
5
4
3
NN10A
3.5
9.1
2.5
36.15.4
18.0
** UNPACKING AND INSPECTION **
UNPACKING INSTRUCTIONS: Carefully unpack urn and inspect immediately for shipping damage. Your automatic coffee urn was
shipped in a carton designed to give it maximum protection in normal handling. It was thoroughly inspected before leaving the
factory and the carrier accepted and signed for it. File any claims for shipping damage or irregularities directly with the carrier, not
with the company.
ASSEMBLY: The four legs, faucets, and vent cap drain are packed separately with urn. Install legs by tilting urn on its side and
screwing legs into urn leg supports until hand tight. Carefully right unit and install in its permanent location, being sure to leave at
least 6" on right side of urn for access to controls. Level urn by adjusting legs. Then attach faucets and install vent cap drain.
Cover(s) are shipped with knob(s) on inside to prevent damage. Simply unscrew and reverse knob(s) and hardware. Your urn
comes with one brew basket and an introductory filter pack. Additional Cecilware filters are available from your dealer.
** INSTALLATION INSTRUCTIONS **
FOR QUALIFIED SERVICE PERSONS ONLY
CAUTION: DO NOT TURN THERMOSTAT ON UNTIL ALL INSTALLATION INSTRUCTIONS HAVE BEEN FOLLOWED.
Water Inlet Connection:
This equipment is to be installed to comply with the applicable Federal, State, or local plumbing codes having jurisdiction. In addition:
1. A quick disconnect water connection or enough extra coiled tubing (at least 2x the depth of the unit) so that the machine can be
moved for cleaning underneath.
2. An approved back flow prevention device, such as a double check valve to be installed between the machine and the water supply.
The automatic coffee urn is equipped with a ¼" Flare Water Inlet Fitting which is located on the back of the unit..
HIGHLY RECOMMENDED:
A WATER SHUT-OFF VALVE and A WATER FILTER, preferably a combination Charcoal/ Phosphate Filter, to remove odors and inhibit
lime and scale build up in the machine.
Note: In areas with extremely hard water, a water softener must be installed in order to prevent a malfunctioning of the equipment and in
order not to void the warranty.
TO PRIME:
CAUTION: THERMOSTAT MUST BE IN THE "OFF" position. Turn on water supply and electrical power to urn and wait until water
is visible in center gauge glass (left-hand gauge glass on 3-gallon single urns). Then turn thermostat knob to 10; thermostat pilot
light shows heater is on. Urn jacket will continue to fill automatically until water reaches the proper level. When indicator on dial
thermometer approaches the "W" in BREW zone, 197°-203°F (92°-95°C), urn is ready to brew coffee. In high altitude locations (at
least 5000 ft, above sea level), thermostat may have to be lowered to prevent boiling.
NOTE: FOLLOW THE ABOVE INSTRUCTIONS FOR INITIAL PRIMING AND AFTER DRAINING URN FOR SERVICING.
** CORRECT PROCEDURES FOR BREWING COFFEE AS RECOMMENDED BY THE COFFEE BREWING CENTER **
1. Use fresh urn grind or drip grind coffee . . . spread evenly on filter for proper extraction.
2. Urn should be connected to cold water supply and water heated to 197°-203°F (92°-95°C) before brewing coffee.
3. While brewing, leave cover on urn to preserve aroma and prevent excessive steaming. Total contact time for urn
grind should be approximately 4-6 minutes.
4. Remove grounds and filter as soon as coffee has dripped through. Never pour coffee back through spent grounds.
5a. Urns with automatic agitator (FE series), blend coffee automatically at end of brewing cycle. Press and hold
agitator ON switch for additional blending.
5b. If urn has a manual agitator (CL series), press and hold agitator ON switch for 15 seconds after brewing cycle to
blend coffee.
5c. Hold coffee at 185°-190°F (85°-88°C) (about 8 on thermostat.) Brewed coffee should not be held for longer than
19K491BHOSE NUT ASSEM BLY (BRITISH T HREAD)11111111111
20H416AWATER INLET TUBE11111111111
21K808ARETAINER MOUNTING BLOCK22223333333
22K810QLEVEL SENSO R, DUAL PROBE11111111111
23L007ATHERMOMETER, BREW DIAL11111111111
24L154ATIMER, MECHANICAL (0 - 15 MINUTES)11111
25L205ATIM ER, SINGLE
25L210ATIM ER, SINGLE
25L214ATIM ER, D UAL
25L216ATIM ER, D UAL
26L155AROCKER SWITCH, POWER ON-OFF 11111111111
27L238ADELAY T IMER-SOLID ST ATE
27L253ADELAY T IMER-SOLID ST ATE
28L780ATHERMOSTAT 25A, URNS11111111111
29L584ASWITCH, PUSHBUTT ON343443
30L775ADUAL LEVEL CONTROL HI-LO
30L776ADUAL LEVEL CONTROL HI-LO
31M005SLEGS (4" ADJ) (4 PER BAG)1111111111 1
32M008AKNOB THERMOSTAT11111111111
33M016ATHERMOSTAT BEZEL11111111 11 1
34M027AKNOB, URN COVER11112222222
35M 326AWATER INLET HOSE 3/8 x 5/ 8 x 8" (IN FEET)11111111111
36M461ASILICONE GROMMET 12mm33333333333
37M462ASILICONE GROMMET 15mm
38M876ABLUE BUTTON (BLEND)111111111
39M877AGREEN BUTTON (BREW)222222
40MA15ACOPPER GASKET, TEFLON FILLED66667777777
41Q027QLINER ASSY & COVER (FE75/ FE100)
41Q094QLINER (FE300)2
41Q204QLINER ASSY & COVER (FE200)
42UB17ASIGHT GLASS RETAINER22223333333
43V002AB REW BASKET , FE75/ FE 10011111111
43V003AB REW BASKET , FE20011
43V081AB REW BASKET , FE3001
4432004INDICATOR LIGHT W/ RED LENS232332
(120V ONLY)
(220V)
(120V ONLY),
(240V)
(120V ONLY),
(240V)
(120V ONLY),
(240V)
(120V ONLY)
(240V)
(120V)
(240V)
(120V)
(240V)
11111111 1
.70 GPM1
, .70 GPM
.35 GPM1111111 1
, .35 GPM
.50 GPM11
, .50 GPM
1111111111 1
11111111
111
(120V)
(240V)
(120V)
(220V ONLY)
1111111111 1
1111111111 1
11112222
CL75-N CH75-N FE100-N FE100-N
DUAL
BREW
111
QUANT ITY
DUAL
BREW
CL100-N CH100-N FE200-N
DUAL
BREW
11
22
CL200-N FE300-N
1
SOLID-STATE TIMER ADJUSTMENT: A factory pre-set electronic solid-state timer controls the volume of water for each
brew cycle. If more or less water is desired, follow these instructions:
Turn knob of timer clockwise to increase volume of water or counterclockwise to decrease it. Run through a complete
brew cycle after each adjustment. Since timer cannot be readjusted in mid-cycle, simply push cycle stop switch at bottom
right of side box if water gets too high. If maximum setting of timer fails to deliver enough water, check water pump and
spray head and follow instructions under maintenance.
SINGLE TIMER
L205A
DUAL TIMER
L214A
MECHANICAL TIMER ADJUSTMENT (ALL CL's & CH's): The factory pre-set mechanical timer can be adjusted for more
or less water by following these instructions:
Remove timer knob and loosen lock nut holding stop pin. To increase volume of water, rotate stop pin clockwise. To
decrease, rotate counterclockwise. Tighten lock nut and replace knob.
MANUAL TIMER
L154A
SPRAY ARM BY-PASS ADJUSTMENT (ALL Urns ): Adjustable bypass allows proper brew extraction even with variations
caused by soft or treated water. If bypass requires adjustment to correct for local water conditions, proceed as follows:
Position spray head over center of coffee liner and press BREW switch. Turn by-pass adjustment screw clockwise to
decrease by-pass flow (for stronger coffee) or counter-clockwise to increase by-pass flow (for weaker coffee).
At end of brewing cycle, note volume of water in coffee liner. Readjust timer if necessary to obtain the correct volume of
water.
BY-PASS ADJUSTMENT
THERMOSTAT ADJUSTMENT: To adjust temperature of water in urn jacket 197°-203°F (92-95°C), turn thermostat knob
to 10 (maximum clockwise position). Pull off knob and insert a small screwdriver into adjusting screw in center of shaft
when temperature on dial thermometer approaches the "W" in the word BREW. Slowly rotate screw clockwise until
thermostat pilot light goes out. Turning screw clockwise lowers temperature
a sealer (glyptol or fingernail polish) to screw after adjustment has been made.
and turning counter-clockwise raises it. Apply
THERMOSTAT ADJUSTMENT
** MAINTENANCE TIPS **
SPRAY ARM ASSEMBLY: The new improved spray head system was designed to facilitate easier cleaning and
maintenance. The swivel valve has a larger flow opening and the spray head cap is equipped with a stainless steel disc,
used to control the flow of water.
When ordering replacement parts, be sure to order the correct disc and spray cap for each urn, as shown in Illustration.
To prevent lime buildup, especially in hard water areas, remove and clean spray head cap and spray head disc frequently. To
clean swivel valve loosen nut and remove spray arm assembly from urn. Remove sediment by inserting a pipe cleaner
through small hole in valve. If maximum setting of timer fails to deliver enough water, check water pump.
CAUTION: DISCONNECT POWER BEFORE ATTEMPTING ANY ELECTRICAL REPAIRS.
IF WATER FAILS TO HEAT:
1. Check line fuse or circuit breaker. Replace or reset if necessary.
2. Make sure thermostat is in ON position. If thermostat pilot light does not come on, replace thermostat. (Refer to
instructions below.) If pilot light is on, measure continuity between terminals l and 2 of thermostat, and between terminals 3
and 4. If a resistance is measured, replace thermostat.
3. If thermostat is okay, check wiring and repair if necessary: if wiring is okay, check heater resistance; if high or infinite,
replace as follows:
REPLACING HEATER:
1. Shut off power and disconnect water supply at elbow. Drain urn.
2. Remove one coffee gauge glass, faucet, shank, and liner.
3. Tilt urn and disconnect wires to heater.
4. Remove socket head screw and heater flange and lift heater out.
5. Install new heater and reassemble urn.
6. Repeat priming instructions on page 2. CAUTION: DO NOT TURN ON THERMOSTAT UNTIL URN IS PRIMED.
REPLACING THERMOSTAT (All Models):
Thermostat is located in side box of urn. Lift off side box door to gain access to thermostat; then follow instructions above.
1. Shut off power, disconnect water supply, and drain urn by opening hot water faucet. When faucet stops running you are
ready to remove the thermostat bulb.
2. Remove thermostat knob and two screws holding thermostat in place.
3. Disconnect wires from thermostat.
4. Pull out thermostat bulb.
5. Install new thermostat, push in the new thermostat bulb. Tighten compression nut on thermostat fitting to prevent leaking
6. Repeat priming instructions. CAUTION: DO NOT TURN ON THERMOSTAT UNTIL URN IS PRIMED.
IF WATER FROM COLD WATER SUPPLY LINE DOES NOT ENTER URN:
1. Check water supply to external shut-off valve.
2. Check fuse on rear of side box and replace if necessary.
3. If water supply and fuse are okay, remove fuse and lift off side box door. exposing terminal block and electrical wiring.
4. Check dual probe liquid level controller. (see component tests)
REPLACING SOLENOID:
1. Shut off water supply, remove fuse, and lift off side box door.
2. Disconnect wires from solenoid: then remove flare nut and unscrew solenoid valve from bracket.
3. Install new solenoid and reinstall fuse and side box door.
4. If necessary, follow priming instructions.
IF WATER RUNS OUT AT OVERFLOW DRAIN:
1. Make sure urn is level and overflow tube is vertical.
2. Remove fuse from rear of side box.
3. If water continues to flow, solenoid valve is dirty or not seating properly. Replace solenoid as described above.
NO WATER FROM SPRAY HEAD:
1. Check fuse first.
2a. For all urns except CL's: Depress BREW switch and release. If switch remains lit, water pump is probably not operating.
Lift off side box door and check if fan on water pump is rotating. If not, replace pump as described below.
2b. For CL urns: Turn brew timer knob clockwise. Replace timer if it does not go on. If timer goes on but pump doesn't,
replace pump.
REPLACING WATER PUMP:
1. Shut off water supply and remove fuse. Drain urn to level of water faucet.
2. Lift off side box door and disconnect the two pump wires.
3. Loosen union fittings on pump and remove pump from urn (Refer to page 15, Installation & Removal of Water Pump.)
4. Replace pump and follow priming instructions on page 2.
CHECKING SOLID-STATE TIMER (ALL URNS EXCEPT CL's): Press and hold BREW switch for 10 seconds. Brew cycle
should start. If water stops coming from spray head as soon as BREW switch is released, timer is not operating. Replace it.
(Instructions below.) If no water comes from spray head when BREW switch is pressed, replace switch.
NOTE: To check mechanical timer on CL urns, refer to NO WATER FROM SPRAY HEAD.
REPLACING SOLID-STATE TIMER:
1. Remove fuse, lift off side box door, and remove timer from bracket.
2. Carefully note locations of colored wires on timer board, then remove wires.
3. Replace timer and reassemble unit in reverse order.
BLENDING - AUTOMATIC TYPE (ALL FE):
OPERATION:
The agitator pump circuit is programmed to operate immediately after brewing cycle. The circuit pumps air through the coffee
gauge glass(es) into the coffee liner(s). The complete cycle takes about 20 seconds. For additional blending, simply press the
BLEND switch.
MAINTENANCE:
If agitation is not sufficient to blend coffee, check flexible tubing , and glasses and fittings, for possible air leaks. Replace as
necessary.
If agitator pump does not operate immediately after brewing cycle or when BLEND switch is pressed, replace agitator pump or
solid state agitator timer.
If agitator pump comes on immediately after brewing cycle, but does not operate when BLEND switch is pressed, replace
BLEND switch.
BLENDING - MANUAL TYPE (CL URNS):
OPERATION:
Immediately after brewing cycle, depress BLEND switch and hold for about 20 seconds. Your coffee will be completely blended
and ready to serve.
MAINTENANCE:
If agitator pump does not operate when BLEND switch is pressed, replace switch, if pump still does not operate, replace pump.
Cleaning the Cecilware
Automatic Coffee Urn....
To ensure the highest quality, best tasting coffee, your
urn must be cleaned daily after the last batch. Regular
cleaning and preventive maintenance is essential in
keeping your coffee urn looking and working like new.
CAUTION - Do not use cleansers, bleach liquids,
powders or any other substance containing chlorine.
These products promote corrosion and will pit the
stainless steel. USE OF THESE PRODUCTS
WILL VOID THE WARRANTY.
WARNI NG - These steps involve working with
very hot water.
Coff ee urns must have a special scouring once a
week. To scour the urn:
1. Be sure urn is full of water at max. brewing
temperat ure.
2. Fill the liner w it h several gallons of water and,
depending on urn size, add at least 1 1/ 2 to 3
ounces of coffee urn cleaning compound. Set the
thermostat to high (NO. 10) , then run a brew
cycle of hot water.
3. Allow solution t o remain in t he liner for
approximately 30 minut es.
4. Scrub the inside of bot h t he liner and t he cover
with a long handled brush.
5. Drain t he cleaning solut ion from the liner. Rinse by
running several brew cycles w ith the sprayhead
centered over the liner. Be sure t o drain the rinse
wat er bet ween cycles.
6.Thoroughly clean t he faucets.
WARNI NG - Never remove the faucet when t he
liner has water or coff ee in it. Switch OFF the
pow er t o t he unit at the circuit breaker. Turn
off the water line running to the urn.
Use a long, thin gauge glass brush to clean the
coffee gauge glass. Use t he same brush to
clean the fitting at t he bot t om of t he liner and
the pipe connected to t he coff ee faucet.
WARNI NG - These steps involve w orking w it h very
hot water.
1. Drain t he urn; then run a brew cycle of hot water.
After spraying hot wat er int o t he liner, t horoughly
brush the liner w it h a long handled brush.
2. Dr ain the wat er and repeat step one. Run anot her
brew cycle. Brush t he liner and drain.
3. Wash the wire brew baskets w ith urn cleaner and
rinse t horoughly.
FAUCET HANDLE
BONNET
SEAT CUP
FAUCET BODY
GND
L2
FE-N SERIES W/ SINGLE TIMER
L1
AIR AGITATOR PUMP
Wht
Wht
BLEND
Yel
NC
Yel
BREW
PUMP
DELAY
TIMER
Blue
Yel
Wht
Blue
Yel
BREW
LIGHT
WATER
INLET
VALVE
Gray
Wht
WATER
LEVEL
PROBES
SINGLE
TIMER
NO
BREW
SWITCH
WATER LEVEL CONTROL
RED
WHT
BLU
YEL
1 FILL
2 AC-1L
3 AC-2N
4 L-LEVEL
5 H-LEVEL
6 COMMON
Red
RedYel
STOP
NC
LED
GND
CONTACTOR
(N FOR 120V)
L2
FE-N SERIES WIRING DIAGRAM
WATER
GND
POWER SWITCH
THERMOSTAT
FUSE
L1
NE249
SH 1 OF 3
FE-N SERIES W/ DUAL TIMER
GND
L2
Wht
Wht
Wht
BLEND
AIR AGITATOR PUMP
DELAY
TIMER
YelBlue
Blue
NC
Yel
Yel
BREW
PUMP
Wht
Yel
HALF
BREW
LIGHT
Gray
Wht
BREW
LIGHT
Purple
Purple
DUAL
TIMER
YelRed
HALF BREW
Wht
SWITCH
BREW
SWITCH
Red
NO
L1
NO
STOP
NC
GND
(N FOR 120V)
L2
WATER
INLET
VALVE
CONTACTOR
WATER
LEVEL
PROBES
WATER LEVEL CONTROL
RED
WHT
BLU
YEL
WATER
GND
POWER SWITCH
1 FILL
2 AC-1L
3 AC-2N
4 L-LEVEL
5 H-LEVEL
6 COMMON
LED
THERMOSTAT
FUSE
L1
FE-N SERIES WIRING DIAGRAM
NE249
SH 2 OF 3
TERMINAL
BLOCK
3 GALLON - SINGLES & TWINS
CONTACTOR
L2L1L3 N
3
2
1
3 PHASE
HEATER
G026A (8 KW)
G024A (6 KW)
TERMINAL
BLOCK
TERMINAL
BLOCK
TERMINAL
BLOCK
L2 L3 N
L1
L1 L2 L3 N
L1 L2 L3 N
CONTACTOR
6 GALLON TWINS
CONTACTOR
CONTACTOR
3
2
1
G013A (8 KW)
G031A (7 KW)
3 PHASE
HEATER
1 PHASE
HEATER
3 PHASE HEATERS
G018A (5 KW EACH)
1 PHASE HEATERS
G011A (5 KW EACH)
1 PHASE
HEATER
3
2
1
TERMINAL
BLOCK
9 GALLON TWINS
L2L1L3 N
CONTACTOR
FE-N SERIES WIRING DIAGRAM
1 PHASE HEATERS
G011A (5 KW EACH)
15 KW, 3 PHASE
NE249
SH 3 OF 3
GL2
BLEND
NC
DELAY
TIMER
AIR AGITATOR
PUMP
1
TIMER
1
L1
NO
2
2
BREW PUMP
WATER INLET VALVE
BREW LIGHT
WATER
LEVEL
PROBES
CONTACTOR
WATER
POWER SWITCH
WATER LEVEL CONTROL
RED
WHT
BLU
YEL
GND
1 FILL
2 AC-1L
3 AC-2N
4 L-LEVEL
5 H-LEVEL
6 COMMON
LED
THERMOSTAT
ON-OFF
FUSE
L2
GND
(N FOR 120V)
CL-N & CH-NSERIES URNS
CECILWARE CORPORATION
L1
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.