COUNTER TOP
ELECTRIC PIZZA OVEN
OPERATION MANUAL ELECTRIC BAKE OVEN
MODELS:
PO-18
PO-22
BK-18
BK-22
SPECIFICATIONS
INSTALLATION
MAINTENANCE TIPS
WIRING DIAGRAMS
LISTED
NSF
THIS UNIT MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL
CODES, OR IN ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL
CODE, ANSI/NFPA 70.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ
THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
CECILWARE CORPORATION
43-05 20TH AVENUE, LONG ISLAND CITY, NY 11105-1295
TEL: 718 932-1414 · FAX: 718-932-7860
NH94A-B 01/06 DH
BK-18 & 22 HAVE ONLY ONE STANDARD STEEL BAKING DECK (LOWER SHELF) OR OPTIONAL
CERAMIC HEARTH BAKE DECK AS PO-18/22. OVENS ARE STACKABLE.
UNIT A B C
PO-18, BK-18 22.5” 23.5” 18.25”
PO-22, BK-22 25.5” 26.5” 21.0”
SHIPPING WEIGHT:
PO-18 PO-22 BK-18 BK-22
138 lbs. 145 lbs. 116 lbs. 123 lbs.
ELECTRICAL SPECIFICATIONS TYPE OF CONNECTION
UNIT VOLTAGE AMPS TOTAL LOAD
PO-18 120 VAC 15.0 A 1800 W NEMA 5-15P NEMA 5-20P
PO-18 220 VAC 13.0 A 2850 W NEMA 6-15P NEMA 6-20P
PO-22 220 VAC 16.4 A 3600 W NEMA 6-20P NEMA 6-30P
BK-18 120 VAC 14.2 A 1700 W NEMA 5-15P NEMA 5-20P
BK-18 220 VAC 8.5 A 1850 W NEMA 6-15P NEMA 6-20P
BK-22 220 VAC 10.0 A 2200 W NEMA 6-15P NEMA 6-15P
Each oven is equipped with a 6 ft. long power cord and plug. A mechanical timer is provided to give an
audible signal at the end of preset time (up to 15 min for po-18/22 up to 60 min for BK-18/22). TIMER
DOES NOT CONTROL THE OVEN.
UNPACKING INSTRUCTION:
counter top oven was shipped in a carton designed to give maximum protection in normal handling. It was
thoroughly inspected before leaving the factory and the carrier accepted and signed for it. File any claims
for shipping damage or irregularities with the carrier.
WARNING:
PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY
GROUNDED THREE-PRONG RECEPTACLE. DO NOT CUT OR REMOVE THE GROUNDING PRONG
FROM THIS PLUG.
LOCATION
surface. Do not store combustible materials on top or under any oven.
MINIMUM CLEARANCE FROM COMBUSTIBLE CONSTRUCTION:
3” FROM SIDES
THIS APPLIANCE IS EQUIPPED WITH THREE-PRONG (GROUNDING) PLUG FOR YOUR
: Due to the heat a counter top oven may produce, it must be placed on a non-combustible
Carefully unpack the oven and inspect immediately for shipping damages. Your
INSTALLATION AND OPERATING INSTRUCTION
3” FROM REAR WALL
USA CANADA
2