COMMERCIAL GAS GRIDDLES
MODEL NOS.
BG 12 BG 36
BG 24 BG 48
CONTENTS:
• GAS DATA
• GENERAL SPECIFICATIONS
• UNPACKING AND INSPECTION
• INSTALLATION
• GRIDDLE PREPARATION
• OPERATION
• MAINTENANCE
• ADJUSTMENTS
• PARTS LIST
HEAVY DUTY
STANDARD FEATURES:
1. 18 gauge aluminized steel unibody construction.
2. 18 gauge stainless steel splash guards. TIG welded to griddle plate for leakproof operation.
3. Heavy Duty .18 gauge aluminized steel burner box construction.
4. Each linear 12 inches of griddle surface has a high efficiency tubular "U" burner for even
temperature distribution.
5. 5/8" thick machine polished griddle plate.
6. 1 gallon capacity grease drawer with baffle.
7. Supplied with adjustable NSF listed legs.
8. A .G.A. design certified.
9. MEA Listed.
10. NSF Listed.
FOR YOUR SAFETY
DO NOT store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
This installation must conform with local codes, with the National Fuel Gas Code, ANSI
Z223.1 (latest edition), Natural Gas Installation Code, CAN/CGA - B149.1, or the Propane
Installation Code, CAN/CGA - B149.2 as applicable.
WARNING: Improper installation, adjustment, alteration, service or maintenance can
result in property damage, injury or death. Read the installation, operating and
maintenance instructions thoroughly before installing or servicing this equipment.
43-05 20th Avenue, Long Island City, NY 11105 • 718-932-1414
FAX: • 718-932-7860
Cecilware sells value... Worldwide.
N788A 5/99
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
SAFETY PRECAUTIONS
FOR YOUR SAFETY. THE FOLLOWING PRECAUTIONS SHOULD BE FOLLOWED AND ENFORCED.
Instructions must be posted in a prominent location and all safety precautions taken in the event the user smells gas.
Obtain this information form you r local gas supplier.
1. IF YOU SMELL GAS:
A. OPEN WINDOW C. EXTINGUISH ANY OPEN FLAME
B. DON'T TOUCH ELECTRICAL SWITCHES D. IMMEDIATELY CALL YOUR GAS SUPPLIER
2. LIGHTING - Follow the instructions on page 3 and on label attached to right side panel of unit.
3. DO NOT place anything over flue opening.
4. DO NOT place combustible or non-combustible materials in the vicinity of the griddle as this could cause fires or obstruct air to
the main burners.
5. This installation must conform with local codes or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1
(latest edition), or the National Gas Installation Code, CAN/CGS-B149.1, or the Propane Installation Code, CAN/CGA -B149.2
as applicable.
6. Provide adequate air supply and ventilation.
7. Provide adequate clearance for air openings into the combustion chamber.
8. Provide clearances for servicing and operation. This unit is for use only on non-combustible floors. Minimum clearances from
combustible and non-combustible construction: 6 inches from side and 6 inches from back.
9. Griddle must be disconnected from gas supply during pressure testing of pipelines in excess of 1/2 psig (3.45KPa) and isolated
(by turning off the manual gas shut -off valve) during any testing to or less than 1/2 psig.
10. Retain this manual for future reference.
MODEL NO. GAS DATA GENERAL DATA
BG48 64,000 4 48 44 18x48
*TOTAL BTU NO. OF BURNERS DIM A DIM B in inches
*NATURAL AND PROPANE AT 4 in. AND 10 in. W.C.
THIS GRIDDLE INTENDED FOR OTHER THAN HOUSEHOLD USE. DESIGN CERTIFIED FOR USE ONLY ON NONCOMBUSTIBLE FLOORS. MINIMUM CLEARANCE FROM COMBUSTIBLE AND NON-COMBUSTIBLE CONSTRUCTION:
6 INCHES FROM SIDE AND 6 INCHES FROM BACK PANEL.
2