CDtechno SX400-U1C, SX400-U1D, SX400-U1B, SX400-U1A Datasheet

Product Data Sheet
400 WATT
AC/DC POWER SUPPLY
SX400
FEATURES
l Active Power Factor Correction l Active Current Sharing With ORing Diodes l FCC/VDE Class B EMI Filter l Optional Active Inrush Current Limit l Compact Size: 10” x 4.85” x 2.19” l Optional SCR Crowbar l Optional Cover With Fan
3400 E Britannia Drive • Tucson, Arizona 85706 • Phone: 520.295.4100 • Fax: 520.770.9369 • Internet: http://www.cdpowerelectronics.com
SX400 2/98 REV A Page 1
DESCRIPTION
The SX400 is a compact 400 watt Power Factor Corrected, single output power supply. Active current sharing circuitry with ORing diodes, to­gether with control functions and alarm options, simplifies N+1 and redundant applications.
AGENCY APPROVALS
See “Safety” section on page 2 for more information
Input Specifications
Parameter Conditions Min Typ Max Units
Operating Range 47-63 Hz 90 264 VAC Inrush Current Limiting
Thermistor 120 VAC, cold start 30 APK
240 VAC, cold start 60 APK
Active Current Limit 264 VAC 19 APK Efficiency Nominal line and full load 75 % Power F actor Correction (PFC) 0.99
Meets IEC 1000-4-7/EN61000-3-2 (formerly IEC 555-2)
Remote Sense
Remote Sense is provided and will compensate for 1.0V of line drop. Remote Sense leads are protected against open, short and reversal.
Remote On/Off (Optional)
The power supply is turned on with a TTL logic ‘1’ (or open) signal and turned off by a switch closure or TTL logic ‘0’ referenced to (-) sense terminal. Consult the factory for other options.
Over V oltage Protection
Output #1: 15% of nominal voltage is typical. The power supply will latch off until AC power is cycled.
Over Current Protection
Automatic recovery upon fault removal.
Transient Response
The peak output voltage e xcursion will not exceed 2% and will recover within 1% in 200 µsec for a 25% step load.
Reverse Voltage Protection
The output is protected to rated load.
Power Fail Signal
Upon AC input voltage remov al, the power fail signal drops to logic zero at least 10msec before loss of DC output. Upon AC input turn-on, signal remains low until output is in regulation. Consult the factor y for other options.
N+1 Load Share
Output has active load sharing circuitry. Units will load share within 1% of the Maximum Rated Load.
Over Temperature Protection
Thermal switch turns off power supply if overheating occurs and automatically restarts.
Safety
UL Recognized:UL File Number E13164 (1950) CSA Certified: CSA File Number LR 9070C
(C22.2 No950, Level 6)
TUV License Number: R9773309 (EN60950) (IEC950)
Cooling
The unit is designed to operate with 30 CFM of airflow.
DC Power Good Signal
The signal is activated by a ±10% loss of regulation Active low or high; TTL Lev el; common with (-) sense. Consult the factory for other options.
SX400 2/98 REV APage 2