Product Data Sheet
350 WATT
AC/DC POWER SUPPLY
NX350
DESCRIPTION
The NX350 is a compact 350 watt Power Factor Corrected, multiple
output power supply. All outputs are fully isolated and regulated.
Active current sharing circuitry, together with control functions
and alarm options, simplifies N+1 and redundant applications.
Fan and disk drive applications are handled by the peak current
ratings of the auxiliary outputs.
FEATURES
!!
! Active Power Factor Correction
!!
!!
! Fully Isolated Outputs
!!
!!
! Low Profile: 9” x 4.85” x 2.00”
!!
!!
! One, Two, Three and Four Output Models
!!
!!
! N+1 Current Sharing
!!
!!
! FCC/VDE Class B EMI Filter Standard
!!
!!
! Optional Fan Mounted On Cover
!!
Internet: http://www.cdpowerelectronics.com
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Phone: 800.547.2537 Fax: 520.770.9369
NX350 3/98 REV B Page 1
AGENCY APPROVALS
Power Electronics Division, Europe
C&D Technologies (Power Electronics) Ltd.
132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland
Tel: +353.61.474.133 Fax:+353.61.474.141
Input Specifications
Parameter Conditions Min Typ Max Units
Operating Range 47-63 Hz 90 264 VAC
Inrush Current Limiting
120VAC, cold start 37 APK
240VAC cold start 70 APK
Efficiency
120V, full load 70 %
240V, full load 75 %
Power Factor Correction (PFC) 0.99
Meets IEC 1000-4-7/EN61000-3-2 (formerly IEC 555-2)
Remote Sense
Remote Sense is provided on Output #1 and will
compensate for 0.7V of line drop. Remote Sense leads are
protected against open, short and reversal.
Remote On/Of
The power supply is turned on with a TTL logic ‘1’ (or open)
signal and turned off by a switch closure or TTL logic ‘0’
referenced to (-) sense terminal. Consult the factory for other
options.
Over Voltag e Protection
Output #1: 6.5V ± 0.5 VDC.
The power supply will latch off until AC power is cycled.
Over Current Protection
Individual current limit on all outputs. Automatic recovery
upon fault removal.
Transient Response
The peak output voltage excursion will not exceed 2% and
will recover within 1% in 200 µsec for a 25% load step
change.
Output Isolation
All outputs are fully isolated.
Power Fail Signal
Upon AC input voltage removal, the power fail signal drops
to logic zero at least 5msec before loss of DC output. On
AC input turn-on, signal remains low until outputs are in
regulation. Consult the factory for other options.
N+1 Load Share
Output #1 has active load sharing circuitry. Units will load
share within 1.5% of Maximum Rated Load.
Over Temperature Protection
Thermal switch turns off power supply if overheating occurs
and automatically restarts.
Safety
UL Recognized: UL File Number E14675 (1950 & 1012)
CSA Certified: CSA File Number LR 9070-154C
(C22.2 No. 234-M90, Level 6)
TUV License Number: R9576031 (EN60950) (IEC950)
Cooling
The unit is designed to operate with 30 CFM of airflow.
NX350 3/98 REV BPage 2