cdtechno NTV0505M, NTV0505M-R, NTV0509M-R, NTV1205M-R, NTV1209M-R Datasheet

...
SELECTION GUIDE
FEATURES
3kVDC Isolation (1 Minute)
Wide Temperature Performance at
Full 1 Watt Load, -40°C to 85°C
Lead Frame Technology
CECC00802 Reflow (280°C)
Efficiency to 82%
Power Density 1.5W/cm
3
5V & 12V Input
5V, 9V, 12V and 15V Output
Footprint Over Pins 1.64cm
2
UL 94V-0 Package Material
No Heatsink Required
Internal SMD Construction
Toroidal Magnetics
Plastic Encapsulated
MTTF up to 2.1 Million Hours
Custom Solutions Available
Multi Layer Ceramic Capacitors
Lead Free Compatibility
Tape and Reel Option
DESCRIPTION
The NTV series of 3kV isolation miniature surface mounted DC-DC Converters employ leadframe technology and transfer moulding techniques to bring all of the benefits of IC style packaging to hybrid circuitry. The devices are fully compatible with CECC00802 to 280°C which allows them to be placed and reflowed with IC’s, thus reducing time and cost in production. The co­planarity of the pin positions is based upon IEC 191-6:1990. The devices are suitable for all applications where high volume production is envisaged.
Nominal Input
Input Output Output Current at Isolation
Voltage Voltage Current Rated Load Efficiency Capacitance MTTF
1
O rd e rC o d e5(V) (V) (mA) (mA) (%) (pF) kHrs
NTV0505M
5 5 ±100 282 71 33 1697
NTV0509M
5 9 ±55 260 77 38 682
NTV0512M
5 12 ±42 253 79 44 343
NTV0515M
5 15 ±33 250 80 43 188
NTV1205M
12 5 ±100 114 73 50 559
NTV1209M
12 9 ±55 105 79 72 375
NTV1212M
12 12 ±42 104 80 89 243
NTV1215M
12 15 ±33 101 82 100 154
When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the additional external capacitance for reliable start up.
1 Calculated using MIL-HDBK-217F with nominal input voltage at full load. 2 See derating curve. 3 12V input types have typically 3% less load regulation change. 4 Supply voltage must be discontinued at the end of the short circuit duration. 5 If components are required in tape and reel format suffix order code with -R, e.g. NTV0505M-R.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
Parameter Conditions MIN TYP MAX Units
Voltage Range
Continuous operation, 5V input types 4.5 5 5.5
V
Continuous operation, 12V input types 10.8 12 13.2
Reflected Ripple Current 41 47 mA p-p
Short circuit duration
4
1second Internal power dissipation 550mW Lead temperature 1.5mm from case for 10 seconds 300°C Input Voltage VIN, NTV05 types 7V Input voltage VIN, NTV12 types 15V
INPUT CHARACTERISTICS
ABSOLUTE MAXIMUM RATINGS
Parameter Conditions MIN TYP MAX Units
Rated Power
2
TA= -40°C to 85°C 1.0 W
Voltage Set Point Accuracy
See tolerance envelope
Line regulation High VINto low V
IN
1.0 1.2 %/%
Load Regulation
3
10% load to rated load, 5V output types 10 12
%
10% load to rated load, 9V output types 6.5 8.0 10% load to rated load, 12V output types 6.0 8.5 10% load to rated load, 15V output types 6.0 7.0
Ripple and Noise
BW=DC to 20MHz, 5V output types 50 75
mV p-p
BW=DC to 20MHz, 9V output types 40 65 BW=DC to 20MHz, 12V output types 40 60 BW=DC to 20MHz, 15V output types 40 60
OUTPUT CHARACTERISTICS
NTV SERIES
3kVDC Isolated 1W Dual Output SM DC-DC Converters
www.dc-dc.com
NTV SERIES
3kVDC Isolated 1W Dual Output SM DC-DC Converters
C&D Technologies (NCL) Ltd
Tanners Drive, Blakelands North Milton Keynes MK14 5BU, England Tel: +44 (0)1908 615232 Fax:+44 (0)1908 617545 email: info@cdtechno-ncl.com
www: http://www.dc-dc.com
C&D Technologies (NCL), Inc.
5816 Creedmoor Road, Raleigh NC 27612, USA Tel: +1 (919) 571-9405 Fax: +1 (919) 571-9262 email: info@us.cdtechno-ncl.com
C&D Technologies (NCL) Limited reserve the right to alter or improve the specification, internal design or manufacturing process at any time, without notice. Please check with your supplier or visit our web site to ensure that you have the current and complete specification for your product before use.
© C&D Technologies (NCL) Limited 2001 NDC NTV.3 No part of this publication may be copied, transmitted or stored in a
retrieval system or reproduced in any way including, but not limited to, photography, photocopy, magnetic or other recording means, without prior written permission from C&D Technologies (NCL) Limited.
Instructions for use are available from www.dc-dc.com
ISOLATION CHARACTERISTICS
GENERAL CHARACTERISTICS
TEMPERATURE CHARACTERISTICS
PERFORMANCE CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
Isolation Test Voltage For 1 Minute 3000 VDC Resistance Viso=1000VDC 10 G
Parameter Conditions MIN TYP MAX Units
Switching Frequency
5V input types 115
kHz
12V input types 115
Parameter Conditions MIN TYP MAX Units
Specification All output types -40 85 °C Storage -55 125 °C Case Temperature
5V output types 46
°C
above ambient
All other output types 35
Cooling Free air convection
tolerance envelope
+10%
+5%
V nominal
temperature derating graph
2.0
1.5
1.0
0.5
0
+2.5%
-2.5%
-7.5%
MECHANICAL DIMENSIONS
10 50 100
Output Load Current (%)
-40 0 50 100 150 Ambient Temperature (°C)
85°C
Safe Operating Area
PIN
1 GND 3 V
IN
5 NA
9 0V 11 -V 12 NA 14 +V 18 NA 20 NA 22 NA
We i g h t:1. 5 3g
For tape and reeling packaging details refer to datasheet NDCAN002.1 All dimensions in mm XX.XX ±0.25mm. All pins on a 2.54mm pitch.
15.24
12.70
11.20
10.40
6.60
(5.95)
(6.35)
5.85
0.65
0.55
0.30
0.20
1.875 MAX
DETAIL A
DETAIL A
1.50
1.20
7.70
2.54
2.10
0.5
REFERENCE PLANE
±5.00°
0.25
0.10
2.79MAX
1 3 5 9 11
121422 1820
0.1S
NTV0505M
XYYWW
0.2
M
P
S
P
10 PINS
SEATING PLANE
S