NTA SERIES
Isolated 1W Dual Output SM DC-DC Converters
SELECTION GUIDE
FEATURES
Wide Temperature Performance at
Full 1Watt Load, -40°C to 85°C
CECC00802 Reflow (280°C)
Dual Isolated Output
1kVDC Isolation
Efficiency to 78%
Power Density 1.36W/cm
3
5V & 12V Input
5V, 9V, 12V and 15V Output
Footprint Over Pins 1.64cm
2
UL 94V-0 Package Material
No Heatsink Required
Internal SMD Construction
Toroidal Magnetics
Plastic Encapsulated
MTTF up to 2.1 Million Hours
Custom Solutions Available
Multi Layer Ceramic Capacitors
Lead Free Compatible
DESCRIPTION
The NTA series of miniature surface mounted DC-DC Converters employ leadframe technology and transfer moulding techniques to bring all of the benefits of IC style packaging to hybrid circuitry. The devices are fully compatible with CECC00802 to 280°C which allows them to be placed and reflowed with IC’s, thus reducing time and cost in production. Co-planarity of the lead positions is based upon IEC 191-6:1990. The devices are suitable for all applications where high volume production is envisaged.
Nominal Input
Input Output Output Current at Isolation
Voltage Voltage Current Rated Load Efficiency Capacitance MTTF
1
Order Code5(V) (V) (mA) (mA) (%) (pF) kHrs
NTA0312M
3.3 12 ±42 390 77 40 375
NTA0315M
3.3 15 ±33 392 77 42 206
NTA0505M
55±100 290 69 33 1697
NTA0509M
59±55267 75 38 682
NTA0512M
5142260 77 44 343
NTA0515M
5133256 78 43 188
NTA1205M
12 5 ±100 121 69 50 559
NTA1209M
12 9 ±55 113 74 72 375
NTA1212M
12 12 ±42 111 75 89 243
NTA1215M
12 15 ±33 110 76 100 154
When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the additional external capacitance for reliable start up.
1 Calculated using MIL-HDBK-217F with nominal input voltage at full load. 2 See derating curve. 3 12V input types have typically 3% less load regulation change. 4 Supply voltage must be discontinued at the end of the short circuit duration. 5 If components are required in tape and reel format suffix order code with -R, e.g. NTA0505M-R
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
Parameter Conditions MIN TYP MAX Units
Continuous operation, 3V input types 2.97 3.3 3.63
Voltage Range Continuous operation, 5V input types 4.5 5 5.5 V
Continuous operation, 12V input types 10.8 12 13.2
Reflected Ripple Current 41 47 mA p-p
Short circuit duration
4
1second Internal power dissipation 550mW Lead temperature 1.5mm from case for 10 seconds 300°C Input Voltage VIN, NTA03 types 5.5V Input Voltage VIN, NTA05 types 7V Input voltage VIN, NTA12 types 15V
INPUT CHARACTERISTICS
ABSOLUTE MAXIMUM RATINGS
Parameter Conditions MIN TYP MAX Units
Rated Power
2
TA= -40°C to 85°C 1.0 W
Voltage Set Point Accuracy
See tolerance envelope
Line regulation High VINto low V
IN
1.0 1.2 %/%
Load Regulation
3
10% load to rated load, 5V output types 10 12
%
10% load to rated load, 9V output types 6.5 8 10% load to rated load, 12V output types 6.0 8.5 10% load to rated load, 15V output types 6.0 7.0
Ripple and Noise
BW=DC to 20MHz, 5V output types 50 100
mV p-p
BW=DC to 20MHz, 9V output types 35 80 BW=DC to 20MHz, 12V output types 50 110 BW=DC to 20MHz, 15V output types 65 110
OUTPUT CHARACTERISTICS
C&D Technologies (NCL) Ltd
Tanners Drive, Blakelands North Milton Keynes MK14 5BU, England Tel: +44 (0)1908 615232 Fax:+44 (0)1908 617545 email: info@cdtechno-ncl.com
www.cdpoweronline.com
C&D Technologies Inc.
3400 E Britannia Drive, Tucson, Arizona 85706, USA Tel: +1 (800) 547-2537 Fax: +1 (520) 741-4598 email: sales@cdtechno.com
NTA SERIES
Isolated 1W Dual Output SM DC-DC Converters
C&D Technologies (NCL) Limited reserve the right to alter or improve the specification, internal design or manufacturing process at any time, without notice. Please check with your supplier or visit our web site to ensure that you have the current and complete specification for your product before use.
© C&D Technologies (NCL) Limited 2003 NDC NTA.3 No part of this publication may be copied, transmitted or stored in a
retrieval system or reproduced in any way including, but not limited to, photography, photocopy, magnetic or other recording means, without prior written permission from C&D Technologies (NCL) Limited.
Instructions for use are available from www.cdpoweronline.com
ISOLATION CHARACTERISTICS
GENERAL CHARACTERISTICS
TEMPERATURE CHARACTERISTICS
PERFORMANCE CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
Isolation Test Voltage Flash tested for 1 second 1000 VDC Resistance Viso=1000VDC 10 G
Parameter Conditions MIN TYP MAX Units
Switching Frequency
3V input types 100
kHz
5V & 12V input types 115
Parameter Conditions MIN TYP MAX Units
Specification All output types -40 85 °C Storage -55 125 °C Case Temperature NTA312M, NTA315M 19 Case Temperature 5V output types 46 °C above ambient All other output types 35 Cooling Free air convection
tolerance envelope
+10%
+5%
V nominal
temperature derating graph
2.0
1.5
1.0
0.5
0
+2.5%
-2.5%
-7.5%
Output Voltage
Output Power (W)
MECHANICAL DIMENSIONS
10 50 100
Output Load Current (%)
-40 0 50 100 150 Ambient Temperature (°C)
85°C
Safe Operating Area
PIN
1 GND 3V
IN
5NA 70V
9-V 10 NA 12 +V 14 NA 16 NA 18 NA
Weight: 1.53g
All dimensions in mm XX.XX ±0.25mm. All pins on a 2.54mm pitch.
15.24
10.16
11.20
10.40
6.60
(5.95)
(6.35)
5.85
0.65
0.55
0.30
0.20
1.8 75 MAX
DETAIL A
DETAIL A
1.50
1.20
7.70
2.54
2.10
0.5
REFERENCE PLANE
±5.00°
0.25
0.10
2.79MAX
13579
1012141618
0.1S
0.2
M
P
S
P
NTA0505M
XYYWW
10 PINS
SEATING PLANE
S