cdtechno NMR100, NMR108, NMR102, NMR101, NMR106 Datasheet

NMR SERIES
Isolated 1W Single Output DC-DC Converters
SELECTION GUIDE
Nominal
Input Output Output Input Current
Voltage Voltage Current at Rated Load MTTF
Order Code (V) (V) (mA) (mA) (%) (pF) kHrs
NMR100 5 5 200 290 69 28 1322
NMR101 5 12 83 260 77 33 235
1
FEATURES
Wide Temperature Performance at
Full 1 Watt Load, –40°C to 85°C
Industry Standard Pinout
1kVDC Isolation
Efficiency to 79%
Power Density up to 0.90W/cm
5V & 12V Input
5V, 12V & 15V Output
Footprint of 1.17cm
UL 94V-0 Package Material
No Heatsink Required
Internal SMD Construction
Toroidal Magnetics
Fully Encapsulated
No External Components Required
MTTF up to 1.6 Million Hours
Custom Solutions Available
No Electrolytic or Tantalum
Capacitors
DESCRIPTION
The NMR series of industrial temperature range DC-DC converters are the standard building blocks for on-board distributed power systems. They are ideally suited for providing single rail supplies on primarily digital boards with the added benefit of galvanic isolation to reduce switching noise. Surface mount technology and advanced packaging materials produce rugged reliable performance over an extended temperature range from –40°C to 85°C.
NMR102 5 15 67 253 79 40 127
NMR106 12 5 200 121 69 36 515
NMR107 12 12 83 110 76 58 184
NMR108 12 15 67 110 76 56 111
When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the additional external capacitance for reliable start up.
INPUT CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
Voltage Range
Reflected Ripple Current 40 60 mA p-p
Continuous operation, 5V input types 4.5 5 5.5 Continuous operation, 12V input types 10.8 12 13.2
V
OUTPUT CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
Rated Power2TA= –40°C to 85°C 1.0 W Voltage Set
Point Accuracy Line Regulation High VINto low V
Load Regulation 10% load to rated load, 12V output types 6.9 7.7 %
Ripple & Noise BW=DC to 20MHz 30 50 mV p-p
See tolerance envelope
10% load to rated load, 5V output types 12.5 13.4
IN
10% load to rated load, 15V output types 6.5 7.5
1.0 1.2 %/%
ABSOLUTE MAXIMUM RATINGS
Short-circuit duration Internal power dissipation 550mW Lead temperature 1.5mm from case for 10 seconds 300°C Input voltage VIN, NME05 types 7V Input voltage VIN, NME12 types 15V
3
1 second
www.dc-dc.com
1 Calculated using MIL-HDBK-217F with nominal input voltage at full load. 2 See derating curve 3 Supply voltage must be discontinued at the end of the short circuit duration.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
NMR SERIES
Isolated 1W Single Output DC-DC Converters
ISOLATION CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
Isolation Test Voltage Flash tested for 1 second 1000 VDC Resistance Viso=1000VDC 10 G
GENERAL CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
Switching Frequency
TEMPERATURE CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
Specification All output types -40 85 °C Storage -50 130 °C Case Temperature
Above Ambient Cooling Free air convection
PERFORMANCE CHARACTERISTICS
tolerance envelope
+10%
+5%
V nominal
5V input types 110 12V input types 160
5V output types 33 All other output types 28
+2.5%
-2.5%
-7.5%
kHz
°C
temperature derating graph
2.0
1.5
1.0
10 50 100
Output Load Current (%)
MECHANICAL DIMENSIONS
7 Pin SIP
19.50
6.00
PIN
1 V
IN
2 GND 4 0V 6 +V
Weight: 2.1g
All dimensions in mm XX.XX ±0.25mm. All pins on a 2.54mm pitch and within ±0.25mm of true position.
4.60
3.60
NMR100
10.0
XYYWWi
1 2 4 6
2.54
Safe Operating Area
0
-40 0 50 100 150 Ambient Temperature (°C)
1.25
0.55
0.45
1.88±0.50
0.55
0.45
0.5
12.70
0.30
0.20
C&D Technologies (NCL) Limited reserve the right to alter or improve the specification, internal design or manufacturing process at any time, without notice. Please check with your supplier or visit our web site to ensure that you have the current and complete specification for your product before use.
© C&D Technologies (NCL) Limited 2001 NDC NMR.3
No part of this publication may be copied, transmitted or stored in a retrieval system or reproduced in any way including, but not limited to, photography, photocopy, magnetic or other recording means, without prior written permission from C&D Technologies (NCL) Limited.
Instructions for use are available from www.dc-dc.com
C&D Technologies (NCL) Ltd
Tanners Drive, Blakelands North Milton Keynes MK14 5BU, England Tel: +44 (0)1908 615232 Fax:+44 (0)1908 617545 email: info@cdtechno-ncl.com
www: http://www.dc-dc.com
C&D Technologies (NCL), Inc.
5816 Creedmoor Road, Raleigh NC 27612, USA Tel: +1 (919) 571-9405 Fax: +1 (919) 571-9262 email: info@us.cdtechno-ncl.com
Loading...