cdtechno NCX10S48033Y, NCX10S24050, NCX10S48050Y, NCX10S48050, NCX10S48033 Datasheet

...
NCX10S SERIES
Isolated 10W Single Output DC/DC Converters
www.cdpoweronline.com
SELECTION GUIDE
1
FEATURES
High Efficiency to 82%
Industry Standard Pinout
UL 60950 Recognition Pending
Non Latching Current Limit
Constant 400kHz Frequency
Versatile Control Options
Continuous Rating to 10W @85°C
Operation to Zero Load
Protected Against Load Faults
Internal Over Temperature Protection
Uses No Electrolytic Capacitors
DESCRIPTION
The NCX10S series of DC/DC Converters combines ease of application with versatility and is available in two pin patterns based on popular industry standards. High efficiency enables full rating to be achieved in a small package without heatsinking, and a high surge capability will provide for start-up and transient loads, whilst being thermally protected against sustained overload. The NCX10S series is currently undergoing testing by Underwriters Laboratory (UL) to UL 60950 for functional insulation.
Order Code V V A mW mW % pF
NCX10S24033
24 3.4 3.1 270 26 78 23
NCX10S24050
24 5.1 2.0 280 25 82 26
NCX10S48033
48 3.4 3.1 500 44 79 29
NCX10S48050
48 5.1 2.0 510 45 82 32
NCX10S24033Y
24 3.4 3.1 270 26 78 23
NCX10S24050Y
24 5.1 2.0 280 25 82 26
NCX10S48033Y
48 3.4 3.1 500 44 79 29
NCX10S48050Y
48 5.1 2.0 510 45 82 32
Parameter Conditions MIN NOM MAX Units
Voltage Range
Continuous operation, 24V input types 18 24 36
V
Continuous operation, 48V input types 36 48 75
Nominal
Input Voltage
Output Voltage
Output Current
Power Consumption
at 0% Load
Power Consumption
at Shutdown
Efficiency (MIN)
Isolation
Capacitance
Parameter Conditions MIN TYP MAX Units
Voltage Set Point Error 50% load 1.0 % Overall
Substrate temperature –40 to 110°C
Voltage Error
Load 0% - 100% 2.5 % Input specified range
Temperature Coefficient of Output Voltage 250 ppm°C (slope)
Deviation of Output Voltage
Temperature MIN - MAX
1.0 %
Current Limit Continuous short circuit causes no damage
NCX10S24033 153
% of
Overload 95% of nominal
NCX10S24050 170
rated
Output Current output voltage
NCX10S48033 148
Output
NCX10S48050 164
Current
Line Regulation Operating voltage range, 50% load 0.1 % Load Regulation 0% - 100% rated load
2
0.5 %
Ripple rms 1.0 %
Input voltage, 24V input types –0.3V to 40V Input voltage, 48V input types –0.3V to 80V Output Voltage –0.3V to regulated voltage Output trim control –1V to +30V relative to output return Shutdown control –0.3V to 6V relative to input return
INPUT CHARACTERISTICS
1
OUTPUT CHARACTERISTICS
1
Parameter Conditions MIN TYP MAX Units
Voltage Trimming At rated load,
±10 %
Range Trim control at either output Remote Switch Input Not operating -0.3 0 1.5 (voltage relative Operating, open circuit voltage
2.6 5.0 6.1
V
to input negative) VINMIN to MAX Start Delay
Time from application of valid input voltage to output being in specification
10 ms
Switching Frequency 360 400 440 kHz
CONTROL CHARACTERISTICS
ABSOLUTE MAXIMUM RATINGS
1 Specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. 2A minimum load of 10% of rating is recommended for typical applications, see application notes.
ENVIRONMENTAL CHARACTERISTICS
APPLICATION NOTES
Parameter Conditions MIN TYP MAX Units
Substrate Temp. Full load –40 125 °C Storage Absolute MAX internal temperature –40 125 °C Thermal Protection Operates at substrate temperature 150 °C
In a typical application, the NCX10S series of DC/DC converters require nothing more than a dc supply of correct polarity and voltage to generate its specified output. These notes are intended to offer help in the use of other facilities offered by these converters, and to provide assistance in achieving their full potential.
VOLTAGE TRIMMING
ISOLATION CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
Isolation Voltage Flash tested for 1 second 1000 VDC Resistance V
ISO
=500VDC 1 G
THERMAL PERFORMANCE
11 10
9 8 7 6 5 4
-40 10 60 110 Ambient Temperature (°C)
NCX10S24033
Ambient Power (W)
Still Air 100lfm 200lfm 300lfm 400lfm
11 10
9 8 7 6 5 4
-40 10 60 110 Ambient Temperature (°C)
NCX10S24050
Ambient Power (W)
Still Air 100lfm 200lfm 300lfm
11 10
9 8 7 6 5 4
-40 10 60 110 Ambient Temperature (°C)
NCX10S48033
Ambient Power (W)
Still Air 100lfm 200lfm
11 10
9 8 7 6 5 4
-40 10 60 110 Ambient Temperature (°C)
NCX10S48050
Ambient Power (W)
Still Air 100lfm
UL 60950 RECOGNITION
(Maximum permissable load in still air)
Part Number -40°C 25°C 70°C 75°C 80°C 85°C 90°C Units
NCX10S24033 10.0 10.0 10.0 9.0 7.9 6.5 5.0 NCX10S24050 10.0 10.0 10.0 10.0 8.9 7.2 5.2
W
NCX10S48033 10.0 10.0 10.0 9.5 8.4 7.1 5.5 NCX10S48050 10.0 10.0 10.0 10.0 10.0 9.6 8.0
NCX10S SERIES
Isolated 10W Single Output DC/DC Converters
DC
DC
+V
IN
–V
IN
+V
OUT
ADJ
100K
0V
Figure 1: Voltage Trimming
The trimming (adjust) input on the secondary side allows output voltage adjustment within the capability of the power circuit.
When open circuit, the trimming pin ADJ operates at near half the output voltage. A basic trimming arrangement consists of a potentiometer of 10kto 100kΩ connected across the output, with its wiper connected to the ADJ pin (see figure 1). Dependent on model, the output will be reduced by about
15% when the wiper is at the positive output, or increased by about 24% when at the negative rail. Regulation will be maintained to at least 10% adjustment either way.
If finer adjustment is required, a resistor may be included between the wiper and the pin. For example, 62kwill restrict a 3.3V model to ±5% adjustment range. The corresponding values for the 5V model is 56kΩ.
Loading...