NCX10S SERIES
Isolated 10W Single Output DC/DC Converters
www.cdpoweronline.com
SELECTION GUIDE
1
FEATURES
■ High Efficiency to 82%
■ 500V Input to Output Isolation
■ Industry Standard Pinout
■ UL 60950 Recognition Pending
■ Non Latching Current Limit
■ Constant 400kHz Frequency
■ Versatile Control Options
■ Continuous Rating to 10W @85°C
■ Operation to Zero Load
■ Protected Against Load Faults
■ Internal Over Temperature Protection
■ Uses No Electrolytic Capacitors
DESCRIPTION
The NCX10S series of DC/DC Converters
combines ease of application with versatility
and is available in two pin patterns based on
popular industry standards. High efficiency
enables full rating to be achieved in a small
package without heatsinking, and a high
surge capability will provide for start-up and
transient loads, whilst being thermally
protected against sustained overload. The
NCX10S series is currently undergoing
testing by Underwriters Laboratory (UL) to UL
60950 for functional insulation.
Order Code V V A mW mW % pF
NCX10S24033
24 3.4 3.1 270 26 78 23
NCX10S24050
24 5.1 2.0 280 25 82 26
NCX10S48033
48 3.4 3.1 500 44 79 29
NCX10S48050
48 5.1 2.0 510 45 82 32
NCX10S24033Y
24 3.4 3.1 270 26 78 23
NCX10S24050Y
24 5.1 2.0 280 25 82 26
NCX10S48033Y
48 3.4 3.1 500 44 79 29
NCX10S48050Y
48 5.1 2.0 510 45 82 32
Parameter Conditions MIN NOM MAX Units
Voltage Range
Continuous operation, 24V input types 18 24 36
V
Continuous operation, 48V input types 36 48 75
Nominal
Input Voltage
Output Voltage
Output Current
Power Consumption
at 0% Load
Power Consumption
at Shutdown
Efficiency (MIN)
Isolation
Capacitance
Parameter Conditions MIN TYP MAX Units
Voltage Set Point Error 50% load 1.0 %
Overall
Substrate temperature –40 to 110°C
Voltage Error
Load 0% - 100% 2.5 %
Input specified range
Temperature Coefficient
of Output Voltage 250 ppm°C
(slope)
Deviation of
Output Voltage
Temperature MIN - MAX
1.0 %
Current Limit Continuous short circuit causes no damage
NCX10S24033 153
% of
Overload 95% of nominal
NCX10S24050 170
rated
Output Current output voltage
NCX10S48033 148
Output
NCX10S48050 164
Current
Line Regulation Operating voltage range, 50% load 0.1 %
Load Regulation 0% - 100% rated load
2
0.5 %
Ripple rms 1.0 %
Input voltage, 24V input types –0.3V to 40V
Input voltage, 48V input types –0.3V to 80V
Output Voltage –0.3V to regulated voltage
Output trim control –1V to +30V relative to output return
Shutdown control –0.3V to 6V relative to input return
INPUT CHARACTERISTICS
1
OUTPUT CHARACTERISTICS
1
Parameter Conditions MIN TYP MAX Units
Voltage Trimming At rated load,
±10 %
Range Trim control at either output
Remote Switch Input Not operating -0.3 0 1.5
(voltage relative Operating, open circuit voltage
2.6 5.0 6.1
V
to input negative) VINMIN to MAX
Start Delay
Time from application of valid input
voltage to output being in specification
10 ms
Switching Frequency 360 400 440 kHz
CONTROL CHARACTERISTICS
ABSOLUTE MAXIMUM RATINGS
1 Specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
2A minimum load of 10% of rating is recommended for typical applications, see application notes.