cdtechno IHB100S4805, IHB100S4803 Datasheet

Corporate: www.cd techno.com Product: www.cd powerelectronics.com
IHB100S
100 Watt Single Output Half Brick DC/DC Converter
33 - 75V Input Range1500VDC Isolation Between
Inputand Output
High Efficiency: 86% TypicalOperation to 100°C Baseplate
Temperature
50µS Transient Recovery,
0-90% Load Step
Primary & Secondary Remote
On/Off
External SynchronizationIHB100S Series Are Approved
to UL/CUL 1950, EN 60950
The IHB100S series standard half brick modules are designed for today’s demanding industrial applications. Available in two wide range inputs, these isolated converters offer many features in the standard models. With a complement of safety agency approvals and low noise operations, the converters respond extremely fast to change in load conditions. Inherent in the design are very well-controlled output voltage and no need for minimum loading.
PRODUCT SELECTION CHART
INPUT
VOLTAGE RATED VOUT (VDC) RATED MAXIMUM IOUT (A)
MODEL (VDC)
IHB100S4803 48 (33-75) 3.3 30 IHB100S4805 48 (33-75) 5.1 20
ABSOLUTE MAX.
RA TINGS
Output Short-Circuit Duration Continuous
Baseplate Temperature +100°C Lead Temperature
(soldering, 10 seconds max) +300°C Storage Temperature +125°C Input to Output Isolation 1500 VDC
EFFICIENCY vs TEMPERATURE
T
= +40°C, nominal input voltage, nominal load, recommended external
CASE
components applied, unless otherwise specified.*
Change in Efficiency (%)
Case Temperature (°C)
SPECIFICATIONS, ALL MODELS
Specifications are at T
PARAMETER CONDITIONS MIN TYP MAX UNITS
Voltage Range 33 48 75 VDC Reflected Ripple Current Peak - Peak 370 mA Input Ripple Rejection DC to 1KHz 50 60 dB Maximum Input Current Output Power = 100W
No Load Power Dissipation P
INPUT
Inrush Charge 0.247 mC Quiescent Operating Current Primary On/Off Disabled 7.5 10 mA Secondary On/Off Disabled 15 20 mA
PARAMETER CONDITIONS MIN TYP MAX UNITS
ISOLATION
Input to Output Peak Test 1500 V Input to Baseplate 1500 VDC Resistance, Input - Output 10 M Capacitance, Input - Output 2000 pF Leakage Current V
GENERAL
Set Point Accuracy V Turn-on Time Within 1% of Nominal V Remote On/Off Control Inputs Primary Open Collector/Drain Sink Current-Logic Low V Vlow 0.8 V Vhigh Open Collector Secondary Open Collector/Drain Sink Current-Logic Low 100 µA Vlow 0.4 V Vhigh Open Collector External Synchronization Input
GENERAL
Frequency 440 520 KHz Pulse Widt h 150 320 nSec Source Impedence 47 Input High Voltage 4 5 V Input Low Voltage 0 1 V Input Impedance 470 Switching Frequency 470 480 490 KHz Weight 3 (85) oz (g)
TEMPERATURE Case Temperature
Operation/Specification -40 +100 °C Storage -55 +125 °C Shutdown +100 +115 °C Thermal Inpedance Case to Ambient 8.2 °C/W
= +40°C nominal input voltage unless otherwise specified.
CASE
V
= 30V 5 A
IN
= 0, V
OUT
IN, Min<VIN<VIN, Max
= 240VAC, 60Hz 180 µA, rms
ISO
= Nominal, IO=I
IN
IN
= V
NOM
OUT
MAX
6W
1%
3.5 5 mSec
7mA
DC
* See Application Notes available on the web at www.cdpowerelectronics.com
Corporate: www.cdtechno.com
IHB100S REV A 10/01