![](/html/99/99a5/99a50426fc4ae7c4fbb7b8c34dcab31fd5eaf051fe2badc5508e6ad868fa30d3/bg1.png)
Model: PT2
4-Event Timer & Clock
Counts 100 hours by minutes & seconds
Features
• 4 channels
• Programmable
• Dual function
• Memory
• Counts up & down in 4 channels separately
or simultaneously
• Clock
• Stopwatch
• Loud and long alarm
• Individual channel sounds
• Stop and restart
• Counts up after zero
• Food-safe ABS plastic
• Sliding mode switch
• 4-way mounting: pocket clip/magnet/stand/loop
• Battery and instructions included
Note: Remove sticker from display before use.
Note: In the following instructions, names of the
control buttons are shown in CAPS. Function
information that appears on the display is shown in
BOLD CAPS.
Battery Installation
Replace battery when LCD becomes dim or alarm level
declines.
1. Remove battery door by turning it counterclockwise.
2. Install a 1.5 V button battery with positive (+)
side up.
3. Replace battery door and lock it by turning
it clockwise.
Operating Instructions
A. Set Clock
1. Select CLOCK mode with sliding mode
switch. 12:000 0 AM will appear after
inserting battery.
2. Press and hold ENTER approximately 2 seconds
until the display ashes.
3. Press HR, MIN and SEC to enter the desired
time. Press and hold button for fast advance.
4. Press ENTER to exit. The PT2 will automatically
exit 3 seconds after the last entry.
B. Count Down
1. Select COUNT DOWN mode with sliding
mode switch. COUNT DOWN will
appear on the display.
2. Press HR, MIN and/or SEC to enter the desired
time. Press and hold button for fast advance.
3. Press START/STOP to start the count down.
Press START/STOP button to interrupt the count.
Press START/STOP button again to resume the
count.
4. When the desired time is reached,
alarm will sound and the timer will
start to count up the “overtime”. OT (OverTime)
and COUNT UP will appear on the display while
TIME’S UP ashes.
5. Press START/STOP to stop the alarm.
The alarm will stop automatically after
60 seconds while the count up continues.
6. Press CLEAR to reset to 0:0000.
Note: The timer will retain any time showing on the
display when the sliding mode switch is moved to
another position.
![](/html/99/99a5/99a50426fc4ae7c4fbb7b8c34dcab31fd5eaf051fe2badc5508e6ad868fa30d3/bg2.png)
C. Count Up
1. Select COUNT UP mode with sliding
mode switch. COUNT UP will appear on
the display.
2. Press START/STOP to start the count up.
If desired, the PT2 can count up from any desired
time by entering that time with the HR, MIN and
SEC buttons.
3. Press START/STOP button to interrupt the count.
Press START/STOP button again to resume
the count.
4. Press CLEAR to reset to 0:0000.
5. The PT2 will count up to 99 hours,
59 minutes, and 59 seconds and stop
at 0:0000, at which time an alarm will sound and
TIME’S UP will ash for 60 seconds. Press any
button to stop alarm.
Note: The timer will retain any time showing on the
display when the sliding mode switch is moved to
another position.
D. Programming 4 Events
This device allows 4 different count down timer
settings temporarily or programmed into memory
(T1, T2, T3 and T4) with respective alarm beeping
sequences:
T1: BEEP in 1 second
T2: BEEP BEEP in 1 second
T3: BEEP BEEP BEEP in 1 second
T4: BEEP BEEP BEEP BEEP in 1 second
1. Count Down
a. Select PROGRAM TIMER mode with
sliding mode switch. T1 and COUNT
DOWN will appear on the display.
b. Press T1 to enter Timer 1 set mode. T1 on the
display will be steady. If a time had previously
been entered in T1, it will appear on the
display. To enter a new time press CLEAR.
If a pre-set time had been entered into T1
memory, press CLEAR and then press ENTER
to clear memory.
c. Press HR, MIN and/or SEC to enter the desired
time. The edited time setting will remain there
as long as the counting cycle is not started/
completed and user may switch to other
operations.
d. To store time in memor y, press ENTER after
entering the desired time. Memory is required
for simultaneous counting.
Note: Any time already in memory will be deleted
when the new time is entered into memory.
e. Press START/STOP to start counting down.
The count may be interrupted by pressing
START/STOP. To resume the count press
START/STOP again.
f. When the desired time is reached, alarm will
sound and TIME’S UP will ash on the display.
g. Press any button to stop the alarm and reset
to 0:0000.
h. Repeat steps b through g for T2, T3 and T4.
2. Count Up
T1, T2, T3 & T4 can be used as count up timers
starting from 0:0000.
a. Press START/STOP to start counting
up or to pause and resume count.
b. The PT2 will count up to 99 hours, 59 minutes,
and 59 seconds and stop at 0:0000, at which
time an alarm will sound and TIME’S UP will
ash for 60 seconds. Press START/STOP to
stop alarm.
Note: The timer will retain any time showing on the
display when the sliding mode switch is moved to
another position.
3. 4-Event Simultaneous Operation
T1, T2, T3 & T4 can be used
simultaneously. The T-number for
the channel selected will be steady while other
channels counting will be ashing.
a. To activate T1, T2, T3 & T4 simultaneously,
hold ENTER and press START/STOP. Timers
will start counting down from the pre-set times
stored in their respective memory or count up
if there is no stored setting.
b. If two or more channels reach zero at the
same time, the channel with the lowest
T-number will sound rst and then the other
channels will sound in descending order.
For example, if T1, T2 and T4 reach zero
simultaneously, T1 will sound rst, then T2,
followed by T4.
c. Press any button to stop alarm.
d. To stop activated timers simultaneously, hold
ENTER and press START/STOP (even though
they were activated individually).
Note: Remove sticker from display before use.