Model: DTF572
ProAccurate® Rotating
Thermocouple Thermometer
-40 to +572°F/-40 to 300°C
for thin cuts of meat, sh or poultry
• NSF® Certied
• 2-5 second response
• 1.5 mm thin tip
• 180° rotating display
• Backlit extra-big digits in white
• 4.5”/11.5 cm probe
• Water resistant (IP54)
• Food-safe ABS plastic
• 304 stainless steel probe
• Auto-off after 3 minutes
• Loop
• Two AAA 1.5V IEC LR03 alkaline batteries (included)
Get Professional Results Every Time!
Perfect for thin cuts of meat, sh or poultry. Simply ip down the rapid-response thermocouple probe and insert it into food as thin as 1/8-inch. The display features extra big digits backlit in white for low light conditions and automatically rotates 180° for easy reading regardless of the hand in which it is held.
Note: Remove sticker from display before use.
Note: In the following instructions, names of the
control buttons are shown in CAPS. Function information that appears on the display is shown in BOLD CAPS.
Battery Installation
Replace batteries when LCD becomes dim or the LOW BATTERY ICON ( ) appears on the display.
1. Power off the unit before installing the batteries. A malfunction may occur if the power is on when the batteries are being installed.
2. Using a small Phillips screwdriver, remove the screws on the battery cover on the back by turning it counter clockwise.
3. Install two 1.5V AAA batteries observing polarity shown here.
4. Replace the battery cover.
5. Fasten the screws on the battery cover on the back by turning them clockwise, being careful not to over-turn.
Note: Use only new batteries of the correct size. Never mix
old and new batteries. Never mix rechargeable and non­rechargeable batteries. Used batteries should always be removed, as they may leak chemicals which may damage the circuits of the thermometer.
Operating Instructions
A. On/Off
1. Pull the probe out to turn the thermometer on.
2. Push the probe back to turn the thermometer off
and conserve battery life.
B. Auto-Off
The DTF572 automatically turns off after 3 minutes of inactivity.
Note: This function is disabled at a temperature of
104°F/40°C or above.
C. Temperature Scale
To select temperature reading in Fahrenheit or Celsius:
1. Press the °F/°C button on the back for
3 seconds to change the scale. The °F or °C symbol changes on the display.
D. Display Orientation
The display rotates automatically according to the orientation of the thermometer.
E. Temperature Measurement
Important: THE PROBE MAY BE DAMAGED IF MEASUREMENT TEMPERATURE IS LOWER THAN
-40°F/-40°C OR HIGHER THAN +572°F/+300°C. Note:
The DTF572 is intended for food service use —
do not use for safety related applications.
1. Flip down the probe until fully extended.
2. Insert the probe at least 0.25"/6.3 mm into the food.
3. The current cooking temperature appears on the display.
4. Wearing a heat resistant glove, ip the probe back into the case when nished.
Important: DO NOT TWIST THE PROBE OR ROTATE IT IN WRONG DIRECTION. EXCEPTIONAL STRESS ON PROBE MAY CAUSE IT TO BREAK. CAUTION: Probe may be HOT af ter use. Always wear a
heat resistant glove to touch the stainless steel probe during or just after cooking. Do not touch with bare
hands.
F. Battery Status
1. When the voltage on the battery is low, the LOW BATTERY ICON ( ) appears on the display.
Note: Clean the thermometer probe before each use.
Important: DO NOT LEAVE THERMOMETER CASE IN HOT OVEN. CASE IS NOT HEAT RESISTANT. HAND WASH AND DRY. DO NOT IMMERSE HOUSING IN LIQUID.
Note for Induction Cooktops: Sometimes, the induction
cooktop magnetic eld may interfere with digital thermometers. If there is interference, briey turn off the induction cooktop to get a digital thermometer reading or use a dial thermometer.
Tip: Meat should be allowed to “rest” for 10 to 15 minutes
after it is removed from oven. This allows time for the meat’s internal temperature to stabilize and the juices to redistribute. This will result in a roast that is both juicier and easier to carve.
Care of Your Product
• Do not submerge any par t of the thermometer case in water.
• Wipe clean with a damp cloth.
• Store the thermometer at room temperature between 32 to 104°F/0 to 40°C.
Precautions
Do not touch with bare handsalways wear heat
resistant gloves to touch the probe during
or after cooking.
• Dispose of used batteries promptly and keep the batteries and thermometer away from children.
• Always read the user manual thoroughly before operating.
• Avoid subjecting the probe or thermometer to an open ame on the BBQ.
• Avoid submerging the probe past the junction (where the probe meets the case) or the case itself. The
junction and/or case are not waterproof.
• Avoid subjecting the probe and/or thermometer to temperatures over 572°F/300°C.
• Clean the probe and thermometer with warm soapy water and dry thoroughly after use.
• Avoid cleaning the unit with an abrasive or corrosive compound, which may scratch the plastic par ts and corrode the electronic circuits.
• Avoid subjecting the thermometer to excessive force, shock, dust, temperature, direct sunlight or humidity. This may result in thermometer malfunction, shorter electronic life span, battery damage and/or distort parts.
• Avoid tampering with the thermometer’s internal components, which may cause battery damage and distort parts.
• Avoid immersing case into water or exposure to heavy rain. The case is not waterproof.
• Do not use the thermometer in microwave oven.
USDA SAFE FOOD TEMPERATURES
* Beef, Veal, Lamb – well ...160°F ..71° C * Beef, Veal, Lamb – medium 145°F ..63°C * Beef, Veal, Lamb – rare ...140°F ..60°C
Poultry . . . . . . . . . . . . . . . 165°F ..74 ° C
* Pork/Ham – pre-cooked...145°F ..63°C
Ground Meat...........160°F ..71°C
* 3 minutes rest time
CANDY TEMPERATURE GUIDE
Jelly .............220°F . . . . . . 104°C
Thread .......230–234°F . . 110–112°C
Soft Ball ...... 234–240°F . . .112–115°C
Firm Ball ......244 –248°F . . 118–120°C
Hard Ball .....250 –266°F . . .121–130°C
Soft Crack ....270–290°F . . .132–143°C
Hard Crack ....300–310°F . . 149 –154°C
Caramelize ....316–338°F . . .158–170° C
HIGH ALTITUDE ADJUSTMENT
FOR CANDY-MAKING
STAGE 2,000 feet 5,000 feet 7,500 feet
Soft Ball 230–236°F 224–230°F 219–225°F Firm Ball 238 –244°F 232–238°F 227–233°F Hard Ball 246 –264°F 240–258°F 235–253°F Soft Crack 266–286°F 260–286°F 255–275°F Hard Crack
296–306°F 290–300°F 285–295°F
Specications
Measurement Range: -40 to +572°F/-40 to 300°C Operating Range: 32~104°F/0~40°C/≤90% RH Unit of Measure: ° F/° C Resolution: 0.1° F/0.1°C Accuracy: -40 to +392°F/-40 to +200°C:
±0.7°F/±0.4°C; above 392°F/200°C: ±1.8°F/±1°C
Water Resilience: IP54 Pr obe Type: Thermocouple Type K Probe Length: 4.5"/11.5 cm probe Sensor Diameter: 1.5 mm thin tip Power: Two 1.5V AAA IEC LR03
alkaline
Dimensions: 1.61 W x 6.34 H x 0.98 D (in)/
4.1 W x 16.1 H x 2.5 D (cm)
Weight: 4.0 oz / 113 g
CAUTION: Avoid keeping the thermometer too close to
objects that continuously generate high heat for long periods (i.e., hot plate). This can cause the thermometer to overheat.
CE Note: This device could be sensitive to electrostatic discharge. If electrostatic discharge or malfunctioning occurs, please re-install the battery to reset this unit.
The information in this document has been reviewed and is believed to be accurate. However, neither the manufacturer nor its afliates assume any responsibility for inaccuracies, errors or omissions that may be contained herein. In no event will the manuf acturer or its af liates be liable for d irect, indirect, special, incidental or consequential damages arisen by using this product or resulting from any defect/omission in this document, even if advised of the possibility of such damages. The manufacturer and its afliates reserve the right to make improvements or changes to this document and the products and services described at any time, without notice or obligation.
5-Year Limited Warranty: Any instrument that proves to be defective in material or workmanship (excluding batteries) within ve years of original purchase will be repaired or replaced without charge upon receipt of the unit prepaid at: CDN, PO Box 10947, Portland, OR 97296- 0947 USA. This warranty does not cover damage in shipment or failure caused by failure to adhere to the accompanying instructions, inadequate maintenance, normal wear and tear, tampering, accident, misuse, unauthorized modication, obvious carelessness or abuse. CDN shall not be liable for any consequential or incidental damages whatsoever.
For mor e detailed
information on ou r
produ cts, plea se visit
www.CDNkitchen.com
*USDA does not endorse any product, service or organization.
© 01-2018 Compo nent Design Nor thwest, Inc. Made in Chi na CD9999372en - 1/18 L-DESIGN 614.525.1472