CCI Thermal Technologies TF User Manual

NEMA 4X RAINTIGHT THERMOSTAT
Installation and Operating
WARNING
READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS THERMOSTAT. Failure to
observe safety information and comply with instructions could result in
PERSONAL INJURY, DEATH AND/OR PROPERTY DAMAGE.
Retain these instructions for future reference. This product, when installed, will be part of an engineered system whose specications and performance characteristics are not designed or controlled by Sunne Controls. You must review your application and national and local codes to assure that your installation will be functional and safe.
Instructions
WARNING
To prevent overheating or re, use this control as an operating or regulating thermostat. ALWAYS USE A BACKUP CONTROL OR ALARM if a control failure could cause the controlled appliance to overheat or could cause a re.
Where thermostat is capable of cycling directly between heating and cooling loads, failure to provide a load transfer switch will result in thermostat failure.
Do not install, use or operate if product appears damaged, the enclosure is cracked or broken or if the sensor has been bent, crimped or is dirty.
APPROPRIATE APPLICATION
This thermostat has been tested by CSA and Underwriters Laboratories Inc. (UL), meets the requirements for NEMA 4X equipment and is suitable for use under the National Electrical Code (NEC), Article 547-4, when used with appropriate watertight connectors (not included).
INSTALLATION
WARNING
To avoid electrical shock or damage to equipment, disconnect all power before installing or servicing.
To avoid potential re and/or explosion, do not use in potentially ammable or explosive atmospheres.
Installation must be made by a trained, qualied service person in accordance with the National Electrical Code (NEC) and all applicable local codes and ordinances. Installation should meet all applicable national, state and local codes. Refer to the appropriate wiring diagram included. Locate the thermostat (Local sensing models) or sensing bulb (remote sensing models) for optimum temperature sensing of the controlled space. Thermostat operation will be affected by unusual heat or cold, such as direct sunlight, near windows or doors or on outside walls.
All ttings and materials used for the installation should be approved, suitable and installed properly for the intended application. For water tightness, the cord seal or conduit hub should be UL listed and be marked 4X. The conduit hub is to be tightened onto the conduit before installing in the enclosure.
Even though this thermostat is sealed, water or dust could enter through improperly sealed wiring. A drip loop should be provided to prevent water or other liquids from entering the thermostat housing. The cord or conduit connections to the enclosure must be water and dust tight. The cover must be tightened securely to compress the gasket and provide a watertight seal. Use only screws provided. Do not over-tighten.
Maximum sensing element withstand temperature is 35°F (20°C) above the highest temperature setting. Maximum temperature for the plastic enclosure is 140°F (60°C).
CAUTION
For use in wet or humid environments or where water tightness is required, failure to use suitable watertight connections and suitable drip loop could allow water to enter the enclosure resulting in thermostat failure.
Use copper wire only. Insulate or wire-nut all unused leads.
Use the grounding provisions provided for connection to the line ground and equipment ground wire.
OPERATION AND CHECK-OUT
Allow one hour or necessary amount of time for the thermostat and system to stabilize for normal operation. This thermostat is factory calibrated and requires no correction on site.
TO CHECK OPERATION OF HEATING SYSTEMS:
Disconnect power.
Place the het/cool selector switch, if applicable, in the heat position.
Adjust the thermostat set point to at least 10°F (5°C) below the temperature of the controlled space.
Restore power.
Slowly adjust the thermostat knob to raise the set point. When the set point reaches the approximate temperature of the controlled space, the heating equipment should start.
TO CHECK OPERATION OF COOLING SYSTEMS:
Disconnect power.
Place the heat/cool selector switch, if applicable, in the cool position.
Adjust the thermostat set point to at least 10°F (5°C) above the temperature of the controlled space.
Restore power.
Slowly adjust the thermostat knob to lower the set point. When the set point reaches the approximate temperature of the controlled space, the cooling equipment should start.
Where applicable, remove knockout(s) by impacting near the inside edge of the knockout to be removed. IMPORTANT: Do not impact, dent
or use the sensor for support. This will cause calibration and/or thermostat failure.
Part No. 67890.Rev.0.01 Issue Date: July 2012 Printed in Canada
Ruffneck™ are registered trademarks of CCI Thermal Technologies Inc.
Copyright© 2012. All rights reserved.
TA109 TA 119 TA115 TRA115
TC115 TRD115
L1
BLACK NEGRO NOIR
TB109 TB119 TB115 TRB115
TE115 TRE115
L1
BLACK NEGRO NOIR
TC109 TC119 TC115 TRC115
TF115 TRF115
L1
BLACK NEGRO NOIR
L2 OR NEUTRAL
L2 O NEUTRO
L2 OU NEUTRE
BLACK NEGRO NOIR
RED ROJO ROUGE
TJ109 TJ119
AUXILLARY LEAD CONDUCTOR AUXILIAR
L1
CONDUCTEUR AUXILIAIRE
BLUE AZUL BLEU
LOAD
CARGA
CHARGE
YELLOW AMARILLO JAUNE
vIOLET VIOLETA VIOLET
L2 OR NEUTRAL
L2 O NEUTRO
L2 OU NEUTRE
L2 OR NEUTRAL
L2 O NEUTRO
L2 OU NEUTRE
HIGH ALTO HAUT
LOW BAJO BAS
BROWN CAFE MARRON
L1
PINK ROSADO ROSE
BLUE AZUL BLEU
BLUE AZUL BLEU
LOAD
CARGA
CHARGE
L1
BLACK NEGRO NOIR
VIOLET VIOLETA VIOLET
RED ROJO ROUGE
LOW STAGE HEAT CALEFACCION DE BAJO NIVEL CHAUFFAGE BAS NIVEAU
L2 OR NEUTRAL
L2 O NEUTRO
L2 OU NEUTRE
LOW STAGE COOL ENFRIAMIENTO DE BAJO NIVEL REFROIDISSEMENT BAS NIVEAU
RED ROJO ROUGE
TH109 TH119
HIGH STAGE COOL ENFRIAMIENTO DE ALTO NIVEL REFROIDISSEMENT HAUT NIVEAU
BLUE AZUL BLEU
COOLING LOAD
CARGA DE ENFFRAMIENTO
CHARGE DE REFROIDISSEMENT
HEATING LOAD CARGA DE CLAEFACCION CHARGE DE CHAUFFAGE
HIGH STAGE HEAT CALEFACCION DE ALTO NIVEL CHAUFFAGE HAUT NIVEAU
L2 OR NEUTRAL
L2 O NEUTRO
L2 OU NEUTRE
LT
LT
LEGEND
LEYENDA
THERMOSTAT WIRING CABLEADO DEL TERMOSTATO CABLAGE DU THERMOSTAT
INOICATES SEQUENCE ON TEMPERATURE RISE INOICALA SECUENCIA CUANDO LA TEMPERAT URA SE ELEVA INOIQUE LA SÉQUENCE DE LA MONTÉE DE TEMPERATURE
LÉGENDE
LT
FIELD WIRING CABLEADO EN EL TERRENO CABLAGE SUR PLACE
LT
LOAD TRANSFER SWITCH INTERRUPTOR DE TRANSFERENCIA DE CARGA INTERRUPTEUR DE TRANSFERT DE CHARGE