CCI Thermal Technologies ET5 User Manual

®
RUFFNECK™ ET5-S THERMOSTAT
Installation Instructions
Electrical Rating:
22 AMP 125-277 VAC ¾ HP @ 125 VAC; 1-1/2 HP @ 250/277 VAC
Location:
Locate the thermostat approximately five (5) feet above the floor in a location that will sense the average temperature of the area to be controlled. Do not mount the thermostat adjacent to water pipes, in drafty areas or other locations that would adversely affect the operation of the thermostat. If the thermostat is mounted on an exterior wall that is not insulated, an insulating pad should be placed between the thermostat and the exterior wall.
Mounting and Wiring: All wiring must comply with National Electrical Codes, local codes and ordinances.
1. Remove the cover of the thermostat and set it aside. Exercise care not to damage the temperature sensing/operating components.
2. Connect the conduit into a standard junction box and place the required wire into box.
3. Mount the thermostat base on the junction box. See Fig. 1 for dimensions.
4. Connections are to be made to switch terminals on the base, see Fig. 2.
2.7 50
Fig. 1 Fig. 2
LI NE
4.6 25
NE UTR AL
LO AD
S PST HE AT ING
*ALL W IR ING
MUST C OMP LY
WITH LO CAL
C ODE S
Edmonton 5918 Roper Road Edmonton, AB T6B 3E1
1-800-661-8529www.ccithermal.com info@ccithermal.com
3419-1.01