CB Tech WATER GUARDIAN MPADC User Manual

WATER GUARDIAN
USER GUIDE
Index
About the Water Guardian
Water Guardian Features
Before You Begin
Water Guardian Drinking Water System
Specications
Connect The Hose To The Housing
Connect The Hose And Diverter Valve To The Faucet
Prepare Your System For Use
Operation
Maintenance
Regarding Filter Capacity
Removing The Old Filter Cartridge
Installing The New Filter Cartridge
Flushing / Disinfecting The System
Warranty
Contaminant Reduction Performance
NSF/ANSI 42 - Aesthetic Effects
NSF/ANSI 53 - Health Effects
Standard 401 Incidental Contaminants
/Emerging Compounds
2
2
3
4
4
5
5
5
7
8
8
8
9
9
10
11
12
12
12
14
Troubleshooting
Frequently Asked Questions
Water Guardian Accessories
15
17
20
Water Guardian User Guide
About The Water Guardian Drinking Water System
The CB Tech Water Guardian Drinking Water System (Model# MPADC)
is designed for use on the countertop next to the sink. It connects to the
existing faucet with a diverter valve that allows free selection between
ltered and unltered water.
The Water Guardian includes accessories and ttings required for
installation.
If installation or operation assistance is required, please contact your
Dealer.
Water Guardian Features
Easy and convenient to use; provides delicious, clear, healthier drinking
water whenever you need it.
Better-tasting beverages - coffee, tea, juices, and drinks of all kinds.
Use for food preparation, improving the taste of fruits and vegetables.
Highest quality water for cooking - better pasta, sauces, soups, etc.
Your pets will love it too!
Guaranteed quality backed by an outstanding customer satisfaction
guarantee and warranty.
Cost-effective solution to meet your budget and replaces costly
bottled water
Attaches easily to your faucet without tools.
Reliable protection for all of your family’s drinking water needs.
2
Before You Begin
CB Tech Drinking Water Systems (DWS) have been extensively tested and
certied by NSF International to provide the highest level of assurance
that the device will perform as claimed. Please read this manual before
proceeding with the installation and use of your system. Installation,
operation, and maintenance requirements are essential to the performance
of your system – failure to follow any instructions or operating parameters
contained herein may lead to product damage or product failure.
Replacement lters can be purchased from the Dealer where the Water
Guardian was originally purchased.
Actual lter life depends on the amount of water used and the level of
impurities in the water. See section Regarding Filter Capacity (Pg 8) for
additional details.
The Water Guardian is not intended for use with microbiologically
unsafe water or non-municipally-treated water. Systems certied for
cyst reduction may be used on disinfected waters that may contain
lterable cysts. See section Frequently Asked Questions (Pg 17) for
additional details.
Do not allow water to freeze in the system. If the system is exposed to
freezing temperatures, drain water from the system and remove the
lter. Allow the lter to thaw before replacing and reusing.
Do not allow water to sit in the system for extended periods of time
(e.g., 10 days or more) without use. See section Flushing / Disinfecting
The System (Pg 10) for additional details.
To dispose of the used lter, remove it from the housing and place
in normal refuse. Filters disposed in a normal landll will not release
any chemical contaminants and may continue to adsorb additional
contaminants in the landll.
Check for compliance with any state or local laws and regulations
before use.
3
Water Guardian Drinking Water System
1. Housing Top (MCL-AD)
2. Filter Cartridge (CBTAD)
1
2
3
3. Black Gasket (MC357)
4. Housing Bottom (MCB-AD)
5. Hose and Diverter Valve
(MC6400)
6. Hand Tool (MC008)
4
65
Specications
Model Name: Approximate Filter Capacity: 750 Gallons Replacement Filter Type: CBTAD Approximate Flow Rate: 0.75 gpm @60 psi House Composition: Polypropylene Rubber Items: Silicone Outlet: 1/4” stem Inlet: 3/8” stem Working Pressure Range: 30 psi (2.1 kg/cm2)
to 100 psi (7.0 kg/cm2)
Operating Temperature Range: 32o F (0o C)
to 100o F (38o C)
- for cold water use only
Particle Retention Size: 0.5 micron (sub-micron)
Certied By: NSF International
Water Guardian (MPADC)
4
Installation
Inspect Your Drinking Water System
1. Inspect your DWS to conrm that it has been received in good condition
and that all parts are included.
2. Determine a countertop location for system placement, factoring in
distance to the faucet for diverter valve and hose connection.
3. Inspect the system housing to conrm that the housing top and bottom
are securely connected.
a. With the system sitting upright, slide the hand tool over the top so
that the ridges on the tool t into the grooves on the housing top.
b. While holding the system base in place, rmly turn the hand tool
clockwise to tighten the housing top.
Connect The Hose To The Housing
1. On the diverter valve and hose, locate the
two stems at the end of the hose opposite the
diverter valve. Identify the large stem (Inlet
Stem) and small stem (Outlet Stem).
2. On the DWS, locate the two ports on the bottom rear of the system housing.
Identify the lower, large port (Inlet Port) and upper, small port (Outlet Port).
3. Insert the Inlet Stem into the Inlet Port by slowly pushing the stem straight
into the port as far as possible. Conrm the connection by pushing the
stem in again.
4. Insert the Outlet Stem into the Outlet Port by slowly pushing the stem
straight into the port as far as possible. Conrm the connection by
pushing the stem in again.
Connect The Hose And Diverter Valve To The Faucet
1. Remove the aerator or screen (if present) from the end of the faucet. If
facing the open end of the spout, rotate the aerator counter-clockwise
to loosen and remove.
5
2. Attach the diverter valve directly to the faucet
spout. If the threads of the diverter valve do not
match the threads of the faucet, use one of the
included faucet adapters to connect the diverter
existing faucet
bypass
lever
swivel attachment ring
valve and faucet. If facing the open end of the
spout, rotate the diverter valve and/or adapter
clockwise to tighten. NOTE: When using a faucet
adapter, the rubber washer in the adapter always
faces up toward the faucet.
Diverter Valve
Attachment
a. If Your Faucet Has an Outside Thread (male
connector): For many faucets with an outside
thread, the diverter valve can attach directly
to the faucet. If the diverter valve does
not attach to the faucet, attach the inside
thread (female connector) adapter, part #
MC106 or MC105, to the faucet, and then
Diverter Valve Attachment
with adapter
attach the diverter valve to the adapter.
b. If Your Faucet Has an Inside Thread (female
*MC105
connector): The diverter valve cannot
directly connect to a faucet with a female
connector. Attach the outside thread (male
*MC106
*MC108
connector) adapter, part# MC108, to the
faucet and then attach the diverter valve to
*MC257
the adapter.
c. If Your Faucet Requires More Room for the
Diverter Valve Connection: Some faucets,
*MC700 Adapters
Many installations do not
require an adapter
particularly sprayer hose faucets, require
additional room for the diverter valve connection. If this applies,
attach the long adapter, part# MC257, to the opening of the
faucet spout/sprayer, and then attach the diverter valve to the
adapter. The DWS may need to be repositioned on the sink to allow
enough room for sprayer faucet use.
d. If the Adapters Do Not Fit Your Faucet: Although the adapters
included with your DWS allow connections with many standard
faucets, they do not cover every type of available faucet connection.
If none of the adapters allow the diverter valve to connect to your
diverter