M AT E R I A L
S PECI F I CAT I O N
S H E E T
CANPEX™ ULTRA Multi-layer Cross-linked Polyethylene (PEX) with Tracer Wire
MATERIALS: All CANPEX ULTRA tubing is manufactured from a cross-linkable high density polyethylene produced by grafting organo-silanes onto a polyethylene base. A catalyst (accelerator) added to the cross­linkable polyethylene during extrusion initiates the cross-linking process. Cross-linking is completed with hot water or steam (sauna). The multi-layered construction ensures the customer that if the pipe is exposed to UV light, its physical properties as well as its long term Chlorine/ORP resistance will be retained at the highest level in the industry today. The exterior layer, also with superior Chlorine/ORP resistance, is provided in blue for easy identification. All Tracer Wire is 14 gauge TW solid copper light colored plastic coated tracer wire.
MARKING & CERTIFICATION: All CANPEX ULTRA tubing is marked with the name VPFL as the manufacturer, nominal size, plastic tubing material designation code PEX 5306 (indicating that the PEX tubing has been tested and
TechData
meets the F876 requirements for minimum chlorine resistance at the end use condition of 100% @140˚F), design pressure and temperature ratings, relevant ASTM standards, manufacturing date and production code, as well as NSF-pw stamps (indicating third-party certification by NSF International for meeting and exceeding performance and toxicological standards, as well as achieving the highest chlorine resistance rating in the PEX industry). NSF conducts random on site inspections of the manufacturing facilities and independently tests CANPEX ULTRA tubing for compliance with physical, performance, and toxicological standards. CANPEX ULTRA is also certified to meet the Uniform Plumbing Code, NSF 14/61, NSF Annex G (Lead Free), CSA (Canadian Standards Association) B137.5 (cNSF), ULC/UL (Underwriters Laboratory) S101/UL263 and ULC S102/E84 through Warnock Hersey.
Lit ho in USA © 2 010 CB Sup plies Lt d.
RECOMMENDED USES: CANPEX ULTRA tubing is intended and recommended for use in hot and cold potable water distribution systems. Design temperature and pressure ratings for CANPEX ULTRA are 160 psi @ 73˚F and 100 psi @ 180˚F. CANPEX ULTRA tubing can be used in continuously recirculating hot water plumbing systemsat temperatures of up to 140˚F while still maintaining excellent chlorine resistance. With the Tracer Wire and the CSA B137.5 CANPEX ULTRA tubing meets all the Ontario Building Code specifications for Water Service Tubing (OBC Trace Wire specification 7.2.11.3). In Ontario when used for Water Service Tubing there is no need for a check valve (as per OBC section 7.6.1.10). For information on the suitability for other hot and cold water applications not listed here, consult with your CB Supplies representative.
HANDLING AND INSTALLATION: CANPEX ULTRA cross-linked polyethylene tubing is tough yet flexible. However, it is softer than metals and may be damaged by abrasion or by objects with cutting edges. Use of these materials in hot and cold water distribution systems must be in accordance with good plumbing practices, applicable code requirements and current installation practices available from CB Supplies. CANPEX ULTRA is manufactured to meet written National standards. Contact a CB Supplies representative or the applicable code enforcement bureau for information about approvals for specific applications.
MATERIAL PROPERTIES:
Propert y ASTM Test Method English Units SI Unit s
Density D 792 0.946 g/cc Melt Index Flexural Modulus Tensile Strength @Yield (2 in/min) D 638 2,900 psi 20 MPa Coefficient of Linear Thermal Expansion @ 68°F D 696 8x102/°F 15x10-5/°C Hydrostatic Design Basis @ 73°F (23°C) D 2837 1,250 psi 8.6 MPa Hydrostatic Design Basis @ 180°F (82°C) D 2837 800 psi 5.5 MPa Vicat Softening Point D 696 255°F 124°C Thermal Conductivity D 177 2.4 Btu-in (hr)(ft2)(°F/in) 3.5x10-3Watts/(cm2)(°C/cm)
1. Befor e Cros s-l inkin g
2. 73° F
1
(190°C/2.16 kg) D 1238 0.7g/10 min
2
D 790 120,000 psi 830 MPa
CB-TEC-2010-4-19
CANPEX™ ULTRA with Tracer Wire
PRESSURE DROP TABLE
Expressed as PSI /FT Pressure Drop
TechData
NSF -pw
NSF In ternational Performance and Health Ef fects (Standards 14 & 61)
ULC/UL S101/UL263 Listed for Fire Resistant & Firestop Products & Systems.
NSF certified to CSA B137.5
IAPMO Certified
Warnock Hersey Cer tified to ULC S102 /E8 4
ANNEX G L ead-free
QUALITY ASSURANCE
When the product is marked with ASTM F876/ F877 and CSA B137.5 designations, it affirms that the product was manufactured, inspected, sampled and tested in accordance with these specifications and it has been found to meet the specified requirements.
CERTIFICATIONS
Indicates that the tubing has been tested and meets the F876 requirements for minimum chlorine resistance at the end use of condition of 100% 140˚F (60˚C) (old domestic re-circulation rating, CL-R). NSF tested according to ASTM Standard F2023, evaluating the oxidative resistance of Cross-linked Polyethylene (PEX) tubing and systems to hot chlorinated water greatly exceeding the minimum chlorine resistance requirements of ASTM F876.
Correct : 8 x O.D.
NOTE: Tubing may be bent to a minimum of 5 x O.D. with approved bend support.
Inorrect : Pipe flattens at the bend
MINIMUM BURST PRESSURE (PSI)
GPM 3/ 8” 1/2” 3/ 4” 1” 1-1/4” 1-1/2”
1 .070 .016
1.5 .149 .034
2.2 .303 .069
2.5 .385* .087
3 .539 .122 .023
3.5 .717 .162 .030
4 .208* .039
5 .314 .059
6 .4 40 .082 .024
7 .586 .109 .032
8 .140 .041
9 .174* .051
10 .211 .062 .024
11 .252 .074 .028
12 .296 .087 .033
13 .34 3 .101 .03 8
14 .116 .044
16 .148* .056 .025
18 .184 .070 .031
20 .224 .08 5 .038
22 .267 .102 .045
24 .119* .053
26 .138 .062
28 .159 .071
30 .180 .080*
32 .203 .091
34 .101
36 .113
38 .125
40 .137
Size
Per ASTM F876/F877
Size 74˚ (23˚C) 180 ˚ (8 2˚C)
3/ 8” 620 275
1/2” 480 215
3/4” 475 210
1” 475 210
1-1/4” 475 210
1-1/2” 475 210
EXAMPLE: To calculate the pressure drop of a 1/2” line, 40 ft. long, with a 3 gpm flow rate, calculate .122 psi x 40 f t. =
4.9 psi pressure drop. Most plumbing codes require 8 psi residual pressure at the fix ture. Refer to your local code requirements
*Indicates 8 fps maximum velocity required by some plumbing codes.
NOTE: Maximum flow for each size based on 12 FPS velocit y. PSI x 2.307 = head loss.
SDR-9 PEX TUBING
ASTM F876/ F877/CTS-OD SDR-9
Stock Code Tubing Size O.D. Wall Thickness No m.
I.D.
PX2 3/ 8” 0.500 ± .003 0.070 ± .010 0.350 .0413 0.50
PX3 1/2” 0.625 ± .003 0.070 ± .010 0.475 .0535 0.92
PX4 3/4” 0.875 ± .004 0.097 ± .010 0.671 .1023 1.82
PX5 1” 1.125 ± .005 0.125 ± .013 0.863 .1689 3.04
NOTE: Dimen sions are in English units. Tolerances shown are ASTM requirements . CANPEX ULTRA is manufactured to w ithin these specifica tions.
Weight Per Ft. Volume (Gal) /100 ft.
CB SUPPLIES LTD.
www.cbsupplies.ca
PHONE: 1-888-PIPE PEX (747-3739) EMAIL: sales@cbsupplies.ca
8125 North Fraser Way Burnaby, BC V5J 5M8 Canada