Cavius 2104-001 User Manual

Page 1
PLEASE READ THIS USER GUIDE CAREFULLY
Page 2
PHOTOELECTRIC SMOKE ALARM DEVICE
Model Number: 2104-001
Developed by CAVIUS™
The smoke alarm is designed for private homes, camping trailers, mobile homes and caravans. It is not recommended for boats.
PLEASE READ THE USER GUIDE
AND RETAIN FOR FUTURE USE.
Page 3
CONTENTS
Technical information _______________________________________________________ 1
1. How to set up and connect alarms ___________________________________________ 5
2. The best areas to install the smoke alarm _____________________________________ 10
3. Areas where NOT to install the smoke alarm ___________________________________ 12
4. Placement _____________________________________________________________ 13
5. Installing the smoke alarm_________________________________________________ 15
6. Testfunction ____________________________________________________________ 18
7. Normal mode ___________________________________________________________ 20
8. Alarm mode ____________________________________________________________ 21
9. Pause/Hush function _____________________________________________________ 2 2
10. Add extra device ________________________________________________________ 2 4
11. Low battery signal _______________________________________________________ 25
12. Battery replacement _____________________________________________________ 26
13. Trouble shooting ________________________________________________________ 2 7
14. Other information _______________________________________________________ 2 8
Page 4
TECHNICAL INFORMATION
The maximum number of alarms that can be interconnected within a house group are 32.
Please note: These must be alarms from the Cavius™.
The distance between interconnected alarms depends on the house layout and they should always be tested after installation. It is not advised to get more than 10m distance between two alarms.
Diameter: 65mm Height: 44mm
1
Page 5
The alarm is powered by a replaceable 3v CR123A lithium battery. Please note that correct operation of the smoke alarm device is ensured by use of one of the following batteries: DURACELL, PANASONIC or HUIDERUI.
Interconnected by RF: 926.365 MHz Complies to standards: AS3786:2014/AC:2008/RCM
2
Page 6
CHAMBER
FILTER
TEST BUTTON
Page 7
MOUNTING
BASE
RED LED
Page 8
DO NOT
REMOVE THE
PRODUCT LABEL
ISOLATION
STRIP
1. HOW TO SET UP AND CONNECT ALARMS:
Start by pulling out the battery isolation strip as shown.
Please note: The product label must not be removed as it contains important information regarding the product.
5
Page 9
All alarms that need to be connected in the house should be put into ‘Link Mode’ by sliding the switch on the back of the alarm to the ‘Link Mode’ position.
1
2
LINK MODE
NORMAL MODE
6
Page 10
The red LED will light up to indicate that ‘Link Mode’ has been selected.
Please note that when the alarms are placed in ‘Link Mode’ they can’t be inserted into the mounting base. Do not take out the battery during ‘Link Mode’ as this will interrupt the
link process.
7
Page 11
Press the button at the top of one alarm only. This alarm will become the Master and will start sending out a specific house code to the other alarms. The red LED will flash.
1
2
8
Page 12
As the other alarms receive the specific house code, they will also flash the LED light.
When all alarms flash the red LED, they are connected and can be switched out of ‘Link Mode’ and installed.
9
Page 13
2. THE BEST AREAS TO INSTALL THE SMOKE ALARM:
• Install an alarm between possible fire sources and bedrooms as a minimum
• Install alarms on each floor of the house, in hallways and stairways
• Alarms in each room such as bedrooms and living rooms.
Additional alarms increase the security.
10
Page 14
11
Smoke Heat
Page 15
3. AREAS WHERE NOT TO INSTALL SMOKE ALARMS:
• In dusty rooms
• At the top of a high pointed ceiling, in corners of a room, and within
50cm of where a ceiling and wall join.
• In rooms where the temperature goes outside +4
o
C to 38oC or above
90% relative humidity not condensing.
• In kitchens, garages, laundries, or too close to fireplaces; areas where
either dampness, gases or heat could occur. Place the alarm where it is reachable in order to test the battery and for maintenance.
12
Page 16
4. PLACEMENT:
The smoke alarm is designed to be installed on a ceiling.
Ceiling installation:
The smoke alarm should be a minimum of 50cm from the wall.
13
Minimum 50cm
from wall
Wall
Ceiling
Page 17
14
Minimum 50cm
from peak.
Ceiling
For catheral or peak ceiling or wall installation:
The smoke alarm should be a minimum of 30 cm and maximum of 50cm from the ceiling.
With a minimum of one smoke alarm per floor and a maximum distance between smoke alarms of 10 meters.
Minimum 30cm and maximum 50cm from ceiling
Wall
Ceiling
Page 18
5. INSTALLING THE SMOKE ALARM:
Detach the alarm from the mounting base by twisting counter clockwise.
Use the mounting base ring to mark the screw holes on the ceiling or the wall.
15
MARK UP
SCREW HOLES
WITH A PEN
Page 19
16
USE THE
ENCLOSED
SCREWS AND
PLUGS
Page 20
Once the mounting base is installed, attach the alarm by twisting clockwise until it clicks. If the battery is either missing or inserted incorrectly, or the switch is in ‘Link Mode’, the smoke alarm will not be able to click into the mounting base.
CLICK THE SMOKE ALARM
FIRMLY INTO THE BASE
TO LOCK
Page 21
6. TEST FUNCTION:
After installation, and at least once per quarter, test all of your alarms to ensure they are operating correctly and are within range of each other.
It is recommended to check visually every week if the LED flashes correctly (every 48sec.)
Press the test button on any alarm for at least 6.5 seconds (count 2 sets of 3 sound sweeps). This will send out a test signal from the alarm; all other connected alarms should receive the signal within a short time. The alarms will emit a short beep and
the LED will ash every 8 seconds for 2 minutes.
NOTE: Test signal will send a reduced RF signal in order to make sure it will work in normal condition.
18
Page 22
When the test signal is sent out, the alarms will respond in two ways:
1. A single beep every 8 seconds indicates that the alarms are connected
and functioning.
2. Three short beeps every 8 seconds indicates a smoke sensor fault.
The alarm should be cleaned by running the vacuum (on a low setting) around the smoke alarm chamber and tested again.
Once the alarms have indicated they are interconnected; the beeps can be stopped on each alarm with a short press of the test button.
TIP: It is safe to cover the sound output hole with your finger during the testing to minimise the sound level emitted.
If any problems occur during testing, visit www.cavius.co.nz or www.cavius.com.au for further trouble shooting.
19
Page 23
7. NORMAL MODE:
In normal mode the LED will flash every 48 seconds to show correct operation.
20
Page 24
8. ALARM MODE:
When a concentration of smoke is detected, the smoke alarm will go into ‘Alarm Mode’. It will sound the alarm signal and the LED will flash.
The smoke alarm will also transmit the alarm signal to the other connected alarms, which will also sound the alarm signal after a short delay.
Please note that only the originating alarm’s LED will flash, so it can be identified.
21
Page 25
9. PAUSE/HUSH FUNCTION:
If the smoke alarms are to set into a false alarm by cooking, fireplace, etc. they can be paused for 10 minutes by pressing the test button on the originating smoke alarm only (indicated by the flashing LED).
The reason of this is that it is necessary to locate the source of the alarm before using the hush function. This is to make sure that it is not a life threatening situation.
22
Page 26
HEAT ALARM
SMOKE ALARM SMOKE ALARM
Page 27
10. ADD EXTRA DEVICE:
All CAVIUS™ interconnected alarms within the
can be added to the system as they run on the same frequency and use the same data protocol.This means that the wireless system can consist of a combination of smoke & heat alarms.
Place all alarms into ‘Link Mode’ and repeat section 1.
Always test connection to all devices by repeating test function section 6 after adding devices.
24
Page 28
11. LOW BATTERY SIGNAL:
Your product has a 5 year battery life.
When the battery is starting its end of life, a short beep will sound out every 48 seconds for 30 days.
The alarm effected by the low battery will only beep, no other connected alarms will sound.
It is safe to change batteries in the alarms without going through the link process again – they will not forget the codes during the battery change process.
25
Page 29
12. BATTERY REPLACEMENT:
To replace the battery, detach the smoke alarm from the mounting base by twisting counterclockwise.
Replace the battery respecting the polarities. Attach the alarm in the mounting base by twisting clockwise until it clicks, and test the alarm.
26
Page 30
13. TROUBLE SHOOTING:
• If you are experiencing false alarms when no smoke is present, there could be dust particles or bugs inside the smoke chamber. To alleviate the issue; run the vacuum around the chamber with the brush attachment.
• High humidity areas can also cause false alarms, try to install smoke alarms outside of these areas. If the smoke alarm does not work when the test button is pushed, the probable cause is a faulty battery.
Check if the battery is worn out and replace it.
Always test the alarm after replacement of battery.
27
Page 31
14. OTHER INFORMATION:
Do not paint the alarm.
Disposal: For battery and product, please dispose properly at the end of life. This is electronic waste which should be recycled.
Please note local regulations about information to your insurance company regarding installed smoke alarms.
28
Page 32
29
Alarm condition aural signal pattern according to ISO 8201.
Page 33
Manufactured by: Aps
Julsøvej 16 - DK8600 Silkeborg. www.cavius.com - [email protected] Manufactured in P.R.C.
Distributor information:
CAVIUS Nano Ltd. 2G Ashley Place, Papamoa, Bay Of Plenty 3118. P.O Box 11241, Palm Beach Plaza, Papamoa, Bay Of Plenty 3151, New Zealand.
www.cavius.co.nz - Hotline: 0800 766533 or 07 542 2191
REP ELEC. Locked Bag 45, Plumpton, NSW 2761, Australia.
www.cavius.com.au - PH: 1300 555 586
30
Page 34
WARRANTY:
Your CAVIUS™ smoke alarm has a 5 year warranty from the date of purchase against defect in material and workmanship. Faulty units during this period can be returned to the place of purchase. You must provide the proof of purchase date and such defects will be repaired, or replaced at the distributors option, without charge. This Warranty only covers defects in materials or workmanship in normal residential use and does not cover damage resulting from negligent handling, misuse or lack of reasonable care. This warranty is in lieu of any other warranty either expressed or implied.
Page 35
126611 rev1
AS 3786:2014
Model Number 2104-001
Page 36
Loading...