Cavaliere CAV-Z01(IS)CL Installation Manual And User's Manual

Page 1
Installation Guide
and Users Manual
IMPORTANT:
Read and save these instructions.
NOTICE:
Installer: Leave this guide with the homeowner Homeowner: Keep this guide for future reference
Wall Mount Range Hood
Rev. 1025u.1d
Page 2
Important Safety Notice
Read all Instructions before Installing and operating this appliance
The installation in this manual is intended for qualied installers, service technicians or persons with • similar qualied background. Installation and electrical wiring must be done by qualied profession­als and in accordance with all applicable codes and standards, including re-rated construction. DO NOT attempt to install this appliance yourself. Injury could result from installing the unit due to lack of appropriate electrical and technical background. Range hood may have very sharp edges; please wear protective gloves if it is necessary to remove any • parts for installing, cleaning or servicing. Activating any switch ON before completing installation may cause ignition or an explosion.• Due to the size and weight of this range hood, two people installation is recommended.
To reduce the risk of re, electric shock, or injury to persons:
For general ventilating use only. DO NOT use to exhaust hazardous or explosive materials and va­pors.
The combustion air ow needed for safe operation of fuel-burning equipment may be affected by this • unit’s operation. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. Before servicing or cleaning unit, switch power OFF at service panel and lock service panel to pre-• vent power from being switched ON accidentally. Clean grease laden surfaces frequently. To reduce the risk of re and to disperse air properly, make
sure to vent air outside. DO NOT vent exhaust into spaces between walls, crawl spaces, ceiling, attics or garages.
Ducted fans MUST always be vented to the outdoors.• Use only metal ductwork and this unit MUST be grounded.• Sufcient air is needed for proper combustion and exhausting of gases through the duct to prevent • back drafting. When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hid-
den utilities.
All electrical wiring must be properly installed, insulated and grounded.• Old duct work should be cleaned or replaced if necessary to avoid the possibility of a grease re.• Check all joints on duct work to insure proper connection and all joints should be properly taped.• Use this unit only in the manner intended by the manufacturer. If you have questions, contact the
vendor.
To reduce the risk of a stove top grease re:
Keep all fan, bafe, spaces, lter, grease tunnel, oil container and grease-laden surfaces clean. Grease • should not be allowed to accumulate on fan, bafe, spaces, lter, grease tunnel and oil container. Always turn range hood ON when cooking at high heat or when cooking aming foods. • Use high settings on cooking range only when necessary.• Never leave surface units unattended at high settings. Boil overs cause smoking and greasy spillovers • that may ignite. Heat oils slowly on low or medium settings.
Page 1
Page 3
Important Safety Notice
Read all Instructions before Installing and operating this appliance
Clean ventilating fan frequently.• Always use appropriate cookware and utensils size.• Always use cookware appropriate for the size of the surface element.
To reduce the risk of injury to persons in the event of a stove top grease re:
SMOTHER FLAMES with a close-tting lid, cookie sheet, or metal tray, then turn OFF the burner. • BECAREFUL TO PREVENT BURNS. NEVER PICK UP A FLAMING PAN—you may be burned. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the ames DO NOT go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT or dial your local emergency service immediately. DO NOT USE WATER, including wet dishcloths or towels — a violent steam explosion will result.• Use an extinguisher ONLY if:
You know you have a Class A, B, C extinguisher, and you already know how to operate it.• The re is small and contained in the area where it is started.• The re department is being called.• You can ght the re with your back to an exit.
To reduce the risk of injury to persons in the event of a gas leaks:
Extinguish any open ame.• DO NOT turn on the range hood fan or any type of ventilator.• DO NOT turn on the lights or any type of appliance.• Open all doors and windows to disperse the gas. If you still smell gas, call the gas company and re • department, or dial your local emergency service immediately.
Your safety and the safety of others is very important. We have provided many important safety mes­sages in this manual and on your appliance. Always read and obey all safety messages. All safety mes­sages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you
what can happen if the instructions are not followed.
WARNING
This is the safety alert symbol. This symbol alerts you to potential hazards that can hurt you and others. All safety messages will follow the safety alert symbol and the word “WARNING”.
The manufacturer and/or distributor/reseller declines all responsibility in the event of failure to ob­serve the instructions given here for installation, maintenance and suitable use of the product. The manufacturer and/or distributor/reseller further declines all responsibility for injury due to neg­ligence and the warranty of the unit automatically expires due to improper maintenance. The manufacturer and/or distributor/reseller will not be held responsible for any damages to per­sonal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood.
Page 2
Page 4
Table of Contents
INSTALLATION
Tools needed....................................................3
Parts supplied...................................................4
Venting requirements.......................................5
Mount heights & clearance...........................5-6
Calculating vent system length.......................6
Venting methods..............................................7
Electrical requirements....................................8
Preparation......................................................9
Installation................................................10-11
Installation overview.....................................11
Tools needed:
USE AND CARE
Range hood operations & diagrams..........12-16
Troubleshooting...........................................17
Use and care information...............................18
Specications..............................................18
MAINTENANCE
Cleaning...............................................19
Replacing the lter & light bulb.....................19
WARRANTY
Coverage & exceptions.................................20
Disclaimer & contact us.................................21
Marker or
pencil
Level
Utility knife
Powered screwdriver or drill
Measuring tape
Adjustable Wrench
Flat-blade and
Philips screw­drivers
Page 3
Page 5
Parts supplied:
Lower standard chimney
Range Hood (vary with model)
Grease cup
Ducting Transition
For sheet rock only
Screw Set
Upper standard chimney
Optional Duct Tube
Mounting Bracket
Bafe Filter Spacer
Bafe Filters
Grease Tunnel
Page 4
Page 6
Venting Requirements Height & Clearance
Vent system must terminate to the outside • (roof or side wall). DO NOT terminate the vent system in an at-
tic or other enclosed area.
DO NOT use 4” (10.2 cm) laundry-type wall
caps.
Use metal/aluminum vent only. Rigid metal/
aluminum vent is recommended. DO NOT use plastic vent.
Always keep the duct clean to ensure proper • airow. Calculate the following gures before instal-• lation:
Distance from the oor to the ceiling.1. Distance between the oor to the coun-2.
tertop/stove (recommend* 28” to 31”). Distance between the countertop/stove 3.
to the range hood. Height of hood and duct cover.4.
For the most efcient & quiet operation:
A distance of 28” to 31” is recommended* • between stove top and the bottom of range
hood.
It is recommended that the range hood be • vented vertically through the roof through 8” (20.3 cm) or bigger round metal/aluminum vent work. The size of the vent should be uniform.• Use no more than three 90° elbows.• Make sure there is a minimum of 24” (61 • cm) of straight vent between the elbows if more than one elbow is used. DO NOT install two elbows together.• The length of vent system and number of • elbows should be kept to a minimum to pro­vide efcient performance. The vent system must have a damper. If • roof or wall cap has a damper, DO NOT use damper (if supplied) on top of the range
hood.
Use silver tape or duct tape to seal all joints • in the vent system. Use caulking to seal exterior wall or roof
opening around the cap.
Cabinet
Height
Range
Hood
Height
Min: 28” Max: 31”
Ceiling
Height
Countertop/Stove
36”
Counter
Top
Cabinet or Single-
piece Chimney
Under Cabinet
Range hood
(Optional)
* Due to different ceiling height congurations, rec-
ommended height may not be applicable.
Page 5
Page 7
IMPORTANT:
A minimum of 8” round (standard for this range hood) or 3-1/4 x 10” rectangular duct (purchased separate-• ly) must be used to maintain maximum airow efciency. Always use rigid type metal/aluminum ducts if available to maximize airow when connecting to provided
duct. Please use Duct Run Calculation below to compute total available duct run when using elbows, transitions and caps.
ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase • duct size from 8” to 9” or 10”. If a reducer is used, install a long reducer instead of a pancake reducer. Re­ducing duct size will restrict airow and decrease airow, thus reduce duct size as far away from opening as possible. If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible.• Minimum mount height between stove top to hood bottom should be no less than 28-inch*.• Maximum mount height between stove top to hood bottom should be no higher than 31-inch*.• It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat • damage and re hazard; while hoods mounted too high will be hard to reach and will loose its performance and efciency. If available, also refer to stove top manufacturer’s height clearance requirements and recommended hood • mounting height above range.
* Due to different ceiling height congurations, recommended height may not be applicable.
Minimum Duct Size:
Round - 8” minimum• Rectangular - 3-1/4 x 10” minimum (requires a 8” to 3-1/4x10” adaptor, not supplied)
Calculating Vent System Length
To calculate the length of the system you need, deduct the equivalent feet for each vent piece used in the system from the recommended maximum duct run.
Duct Run Calculation:
Recommended maximum run
8” or 3-1/4 x 10” duct 50 ft
Vent piece deduction Each 90º elbow used 9 ft Each 45º elbow used 5 ft Each 8” to 3/14 x 10” transition used 7 ft Side wall cap with damper 0 ft Roof cap 0 ft
Duct Run Calcuation example:
One roof cap, two 90º elbow, and one 45º elbow used:
0ft + 9ft + 9ft + 5ft = 23ft used.
Deduct 23ft from 50ft, 27ft maximum available for
straight duct run.
Page 6
Page 8
Venting Methods
This range hood is factory set for venting through the roof or wall.• Vent work can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed.
IMPORTANT:
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or • garages. All exhaust must be ducted to the outside. Use metal/aluminum duct work only. • Fasten all connections with sheet metal screws and tape all joints with certied Silver Tape or Duct Tape.• Use caulking to seal exterior wall or roof opening around the cap.
Horizontal wall venting
Option 1:
Option 2:
Side wall cap
Vertical roof venting
Roof cap
Page 7
Page 9
Electrical Requirements
IMPORTANT: For Europe and Other Countries with 220~240V/50Hz, please observe your local governing
codes and ordinances.
It is the customer’s responsibility:
To contact a qualied electrical installer.• To assure that the electrical installation is adequate and in conformance with National Electrical Code, • ANSI/NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22. 2 No. 0-M91 - latest edition** and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualied electrician determine that
the ground path is adequate.
A 110~120V/60Hz, AC-only, fused electrical supply is required on a separate 15-amp circuit, fused on both
sides of the line. Do not ground to a gas pipe.
Check with a qualied electrician if you are not sure that the range hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
IMPORTANT: Save Installation Instructions for electrical inspector’s use.
The range hood must be connected with copper wire/plug only. The range hood should be connected directly to the fused disconnect (or circuit breaker) box through exible armored or non-metallic sheathed copper cable. A U.L. - or C.S.A. - listed strain relief must be provided at each end of the power supply cable.
Wire sizes (COPPER WIRE ONLY) and connections must conform with the rating of the appliance as specied on the model/serial rating label. Wire sizes must conform to the requirements of the National Electrical Code ANSI/NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code Part 1 and C22. 2 No. 0-M91 - latest edition** and all local codes and ordinances. A U.L. - or C.S.A. - listed conduit connector must be provided at each end of the power supply cable (at the range hood and at the junction box).
Copies of the standards listed may be obtained from:
* National Fire Protection Association
Batterymarch Park Quincy, Massachusetts 02269
** CSA International
8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575
Page 8
Page 10
Preparation
Advanced Preparations:
Be familiar with the controls of the range hood by reading 1.
through Range Hood Operations, Page 12.
Place the range hood on a at, stable surface. Connect the 2.
range hood to a designated standard outlet, 110~120V/60Hz (220~240V/50Hz for Europe & other countries), AC only and turn on the range hood. Verify all operations of the range hood by referring to Range Hood Operations, Page
12.
Place all supplied parts and required hardware on a at, stable surface and verify the existence of all sup-3.
plied parts listed on Page 4.
Carefully remove the white plastic protective coat from the chimney covers and range hood.4.
Preparations:
Determine and mark the center line on the ceiling where the range hood will be installed. Make sure there is 1.
proper clearance within the ceiling or wall for exhaust vent.
Due to the weight and size of this unit, please make sure that the support system or framework being used is 2.
stable and secure in the wall.
Put a thick, protective covering over counter top, cook top or range to protect from damage or dirt. Remove 3.
any hazardous objects around the area when installing.
Mark the locations of the support mounting bracket holes, vent cutout (if used) and power supply cable cut-4.
out on the ceiling. Use drill and saber saw or keyhole saw to cut openings for power supply cable and vent (see Venting Methods and Electrical requirements, Pages 7-8).
If venting to the outside install vent system (see 5. Venting Requirements, Page 5). Use caulking to seal exte-
rior wall or roof openings.
Disconnect main electrical supply, prepare and run electrical wiring through ceiling or wall. Leave approxi-6.
mately 12” of electrical cord hanging from the ceiling. Do not restore power until wiring is completed.
Disconnect power cord, remove the stainless steel bafe lters by pulling down toward the direction of solid 7.
arrow while holding both of the metal handles, gently pull the stainless steel bafe lters toward the direc-
tion of dashed arrow as shown in Figure 1 and the grease tunnel.
Remove the grease cup by sliding it sideway, see Figure 2 for location of the grease cup.8. Set aside the stainless steel bafe lters, grease tunnel and grease cup until the range hood is properly in-9.
stalled.
If the range hood comes with a glass canopy and has not already been mounted to the hood, loosen the four 10.
canopy screws and washers from the hood top, carefully place the canopy on the hood top, and loosely tighten the four canopy screws along with washers. DO NOT put excessive pressure against the glass.
Require three or more person to move and install this range hood. Spinal or other bodi-
ly injuries could occur if it is not followed.
WARNING
Excessive Weight
Figure 1
Figure 2
WARNING
Severe Injury
Rotating fan can cause severe injury. Stay clear of fan when
motor is running.
Page 9
Page 11
Installation
Installations (refer to page 4 & 11 for parts):
Measure the distance between stove top and the bottom 1.
of range hood. A distance of 28” to 31” is required.
Make sure the range hood is level and not tilted. Mark 2.
the locations of the hanging bracket holes on the wall as
shown in Figure 3A and Figure 3B.
Place the mounting bracket 3. directly above the range
hood, level it, and mark the locations of the mounting bracket holes on the wall.
Place aside all equipments, locate marked regions and drill holes. Attach range hood to wall using anchors 4.
recommended for your type of wall:
Sheet rock wall: Attach range hood to stud blockings if possible. If stud blockings are not available, it is
required to build a supporting structure behind the sheet rock for best weight support. Concrete wall: Use designated screws (not provided).• Wood wall: Use at least 5 cm long wood screws (not provided).
Fasten two Type “A” anchors (for range hood and for mounting bracket or air diverter) on the wall as shown 6.
in Figure 4. Loosely fasten two Type “B” screws onto anchors, DO NOT fasten screws all the way. Hang the range hood on the Type “B” screws and hand tighten them. Leave approximately 1/8” of gap from the wall to the
range hood.
Place the mounting bracket against the wall and align the holes from mounting bracket with holes from Type 7.
“A” anchors, fasten two Type “B” screws through the holes onto the anchors as shown in Figure 5. Leave ap-
proximately 1/8” of gap from the wall to the mounting bracket.
Figure 3A
Secure
upper
support
frame
Figure 4
Figure 3B
Fasten mounting
bracket
Slide up and secure
upper chimney to mounting bracket
Hold in position and
secure lower chimney
to range hood
Figure 5
Page 10
Page 12
Installation (Continued)
Calculate8. the height of the duct tube and extend approximately 6” (15 cm) longer than required, connect the
lower end of the duct tube to the range hood and the upper end to the vent system. Make sure the main electri­cal supply remains disconnected then connect power plug to the electrical cord or wall plug. Have one person carefully position both upper and lower chimneys on the range hood, let the second person 9. slide the sides of the chimneys into the 1/8” gap. Fasten both chimneys with four Type “C” screws. Install grease tunnel and stainless steel bafe lters then check the operation of the range hood.10.
For sheet rock only
Installation Overview
C
Air Movement Direction
A B
Mounting Bracket
Upper chimney
8” Round duct (exhaust)
Lower chimney
Note: Type “A” anchors are designed
for dry wall. Not to be used with any other types of walls.
C
A B
Wall mount range hood
Page 11
Page 13
Range Hood Operations
Control Panel Layout and Buttons Congurations:
Power
Decrease Value
Blower Power Indicator
Blower Speed Indicator
Light Power Indicator
This range hood is designed to remove smoke, cooking vapors and odors from the cook top area. For best re­sults, start the range hood before cooking and allow it to operate several minutes after the cooking is completed to clear all smoke and odors from the kitchen.
Button functions:
Power: Power ON/OFF the range hood and activate power-off delay timer.• Decrease Value: Blower (motor) speed decrease, timer value decrease, and enter timer mode.• Increase Value: Blower (motor) speed increase timer value increase, and cumulative timer reset.• Blower Power Indicator: Lights up when blower (motor) is running.• Blower Speed Indicator: Shows current blower (motor) speed (1-6).• Light Power Indicator: Lights up when lights turned on.• Light: Turns ON/OFF and dim halogen lights.• Power-On Elapsed Digital Timer: Indicates the accumulated time the system is running.• Power-Off Delay Digital Timer: Indicates the length of time left for delay off function.• Power-Off Delay Timer Indicator: Lights up when auto-shutdown delay timer function is on.
Controls:
Automatic cleaning reminder:
This range hood is equipped with a cleaning reminder that will activate following 30 hours of use. • When blower (motor) starts to rotate, cumulative running time will be shown in Power-On Elapsed Digital Timer. This timer icon ashes when 30 hours is up and reminds user to clean the aluminum lter. After cleaning the lter and when the motor is not in use, press and hold Increase Value button over 3 seconds to reset the timer. Please note that turning off the system will not reset the Power-On
Elapsed Digital Timer.
Adjusting the blower (motor) speed:
Press Power button once to turn on the system. The Blower Power Indicator icon ashes showing that the blower (motor) is ready. Decrease Value button will decrease the speed of the blower (mo- tor) from 6 to 1 (strongest to quietest). Increase Value button will increase the speed of the blower (motor) from 1 to 6 (quietest to strongest). Press Power button once to turn off the system.
Note: The system saves user congurations, hence settings such as light, timer and blower (motor) speed
will remain the same the next time it is turned on.
Light
Increase Value
Power-On Elapsed Digital Timer
Power-Off Delay Digital Timer
Power-Off Delay Timer Indicator
Page 12
Page 14
Range Hood Operations (Continued)
Control Panel Layout and Buttons Congurations:
Power
Decrease Value
Blower Power Indicator
Blower Speed Indicator
Light Power Indicator
Controls:
Adjusting the timer function:
While the blower (motor) is not running, press and hold Decrease Value button over 3 seconds to enter timer mode. Adjust to desired period of delay off timer by pressing Increase Value or Decrease Value button (minimum 1 minute to maximum 15 minutes). This setting will be saved immediately.
Activating the timer function:
While the blower (motor) is running, press and hold Power button for over 3 seconds to activate delay off timer. Power-off delay indicator will lit up and power-off delay digital timer will begin to countdown, when it reaches zero, the blower (motor) will shut down.
Adjusting the light:
Press Light button once to turn on the lights, and once again to turn off the lights. While the lights are off, press and hold Light button for over 3 seconds to dim the lights from low to high. Level of brightness will be stored in system’s memory.
Light
Increase Value
Power-On Elapsed Digital Timer
Power-Off Delay Digital Timer
Power-Off Delay Timer Indicator
Note: Light settings are independent from other settings (including power-off delay) and lights has to be
manually turned on or off.
Note: The system saves user congurations, hence settings such as light, timer and blower (motor) speed
will remain the same the next time it is turned on.
Page 13
Page 15
Measurements & Diagrams
Control type 1 - Touch Sensitive Version (Six speed with type GU10 bulb)
Control type 1 - Touch Sensitive Version (Six speed with type MR16 bulb)
12V/75W
Transformer
Page 14
Page 16
Measurements & Diagrams (Continued)
Control type 1 - Soft-Touch Version (Six speed with type GU10 bulb)
Control type 1 - Soft-Touch Version (Six speed with type MR16 bulb)
Transformer
12V/75W
Page 15
Page 17
Measurements & Diagrams (Continued)
All measurements in parenthesis are in millimeter.• All inch measurements are converted from millimeters, thus inch measurements are estimated.
Page 16
Page 18
Troubleshooting
If the range hood does not operate after installa-1. tion:
The range hood vibrates when the blower is on:2. The range hood might not have been secured prop-
The blowers seems weak:3. Check that the duct sized used is at least 8” (20
The lights work but the blower is not spinning at 4. all, is stuck or is rattling.
Check if the range hood has been plugged in, make • sure that all power has been turned back on and all electrical wiring are properly connected. Swap out light assembly to working ones to deter-• mine whether it is caused by defective bulbs. (See Replacing the light bulbs, page 19)
erly on to the ceiling.
cm). Range hood WILL NOT function efciently with insufcient duct size. For example: 10” (25.4 cm) duct over 8” (20 cm) hole and loosely secured. Check if duct is clogged or if damper unit is not • opening properly. A tight mesh on a side wall cap unit might also cause restriction to the air ow.
The blower might be jammed or scraping the bot-
tom due to shipping damage.
The hood is not venting out properly:5. Make sure the distance between the cook top and
NOTE: For all other inquiries, please contact your local reseller.
the bottom of the hood is within 28” (71 cm) and 31” (79 cm) in range. Reduce the number of elbows and length of duct • work. Check if all joints are properly connected, sealed, and taped. Make sure the power is on high speed for heavy • cooking
Page 17
Page 19
Use and Care Information
WARNING — TO REDUCE THE RISK OF FIRE, ELEC­TRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Use this unit only in the manner in­tended by the manufacturer. If you have questions, contact the manufacturer. Before servicing or cleaning unit, switch power off at service panel and lock switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service discon­necting means cannot blocked, securely fasten prominent
warning device such as a tag to the service panel.
CAUTION: For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. WARNING — TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: Never leave surface units unattended at high settings. Boil overs cause smoking and greasy spill­overs that may ignite. Heat oils slowly on low or medium
settings.
Always turn hood ON when cooking at high heat or when cooking aming foods. Clean ventilating fans frequently. Grease should not be al-
lowed to accumulate on fan or lter. Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING — TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING: SMOTHER FLAMES with a close-tting lid, cookie sheet, or metal tray, then turn off the burner. BECAREFUL TO PREVENT BURNS. If the ames do not go out immediately, EVACU­ATE AND CALL THE FIRE DEPARTMENT. NEVER PICK UP A FLAMING PAN— you may be burned. DO NOT USE WATER, including wet dishcloths or towels — a violent steam explosion will result. Use an extinguish­er ONLY if: You know you have a Class ABC extinguisher, and you already know how to operate it. The re is small and contained in the area where it is
started.
The re department is being called. You can ght the re with your back to an exit.
Specications
Specications*:
Body Stainless Steel
Power Rating 110~120V/60Hz or 220~240V/50Hz (for Europe & other countries)
General Input Power 323 W (218W + 3x35W)
Motor Input Power 218 W (Dual Motors)
Motor Revolution 800 RPM (±10%) to 2100 RPM (±10%)
Levels Of Speed Control 6 Levels
Maximum Airow 1200 (±10%) CFM
Air Pressure 320 pa
Noise Level (dB / sone) Approximately 28 / 0.7 to 53 / 5.6 (Lowest to highest Speed)
Motor Type Dual Chamber Ultra Quiet
Fan Type Dual Centrifugal / Sirocco
Control Type 6 Speed Electronic Control Panels with LED Display
Illumination 35W Maximum, Dimmable
Venting Size 8 inch (20 cm) Round
Interference Protection Radio Frequency Interference Protected
1. In House Test Static Pressure “0”.
2. One sone is roughly equivalent to the sound of a refrigerator (1kHz) at 40 decibels.
3. Subject to change without notice, please contact your local reseller for details.
Page 18
Page 20
Maintenance
SAFETY WARNING: Never put your hand into area housing the fan while the fan is operating!
For optimal operation, clean range hood and all bafe/spacer/lter/grease tunnel/oil container regularly. Regular care will
help preserve the appearance of the range hood.
Cleaning Exterior surfaces:
Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent (e.g. Comet
Power Scruv®, EZ-Off® oven cleaner), or steel wool/scoring pads, which will scratch and damage the stainless steel surface. For heavier soil use liquid degrease such as “Forumla 409®” or “Fantastic®” brand cleaner.
If hood looks splotchy (stainless steel hood), use a stainless steel cleaner to clean the surface of the hood. Avoid getting
cleaning solution onto or into the control panel. Follow directions of the stainless steel cleaner. CAUTION: Do not
leave on too long as this may cause damage to hood nish. Use soft towel to wipe off the cleaning solution, gently rub off any stubborn spots. Use dry soft towel to dry the hood.
After cleaning, you may use non abrasive stainless steel polish such as 3M
luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain. DO NOT allow deposits to accumulate or remain on the hood.• DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface and cause rusting.• DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel
for extended periods. Many of these compounds contain chemicals, which may be harmful. Rinse with water after ex-
posure and wipe dry with a clean cloth.
Cleaning Stainless Steel Bafe Filters:
IMPORTANT: Drain oil from oil containers before oil and residue overow!
The metal lters tted by the factory are intended to lter out residue and grease from cooking. It need not be replaced
on a regular basis but are required to be kept clean. Filters should be cleaned after every 30 hours of use.• Remove and clean by hand or dishwasher. Spray “Formula 409
if heavily soiled. Dry lters and re-install before using hood.
®
” or equivalent degreasing detergent and leave to soak
®
or ZEP®, to polish and buff out the stainless
Replacing Filters:
The stainless steel bafe lters are designed to last but are required to be replaced if damaged, please contact your local
reseller for replacement lters.
Replacing the light bulb:
This range hood uses halogen bulb (please refer to the actual specication of the hood purchased):
USA/Canada: 35W Type MR16 12V / Type GU10 120V Europe and other Countries: 35W Type MR16 12V / Type GU10 220V
Make sure the range hood is unplugged or turn OFF breaker. • Make sure the lights are cool to touch, carefully align the ar-
row on the inner ring with the arrow on the outer ring where it
says OPEN. The inner ring will loosen and the light bulb will
be available for removal. Install a new halogen light bulb and
reverse the steps.
Turn ON breaker and range hood to test for operation.
WARNING
Hazard of Burns!
Light bulb become extremely hot when turned on. DO NOT touch bulb until switched off and cooled.
Touching hot bulbs could cause serious burns.
Align arrows on both rings
Page 19
Page 21
Warranty
TO OBTAIN SERVICE UNDER WARRANTY:
You must present proof of original purchase date.
Please provide an original dated proof of purchase (sales receipt / invoice) in order to obtain service under warranty.
One Year Parts Warranty:
For one year from the date of original purchase, your local reseller will provide free of charge, non-consumable replace­ment parts or components that failed due to manufacturing defects. Subject to the conditions and limitations set forth below, your local reseller will, at its option, either repair or replace any part of its products that prove defective by reason of improper workmanship or materials. Repaired parts or replacement products will be provided by your local reseller on an exchange basis, and will be either new or refurbished to be functionally equivalent to new. The consumer is re­sponsible for all shipping costs. Consumable parts not covered by this warranty include but not limited to: Light bulbs, metal, aluminum and charcoal lters.
Who is Covered:
This warranty is extended to the original purchaser for products purchased for ordinary home use.
This Warranty Will Be Voided When:
Product damaged through negligence, improper installation, accident, abuse, misuse, natural disaster, insufcient or excessive electrical supply, abnormal mechanical or environmental conditions, or any unauthorized disassembly, repair, modication, or failure to follow installation instructions. When product is used commercially or other than its intended purpose. Damaged because of improper connection with equipment of other manufacturers. Repaired or modied by anyone other than your local reseller’s authorized agents. This limited warranty also does not apply to any product on which the original identication information has been altered, obliterated or removed, has not been handled or packaged correctly or has been sold as second-hand.
What is Not Covered:
Consumable parts such as light bulbs, metal and charcoal lters. The natural wear of nish, and wear due to improper maintenance, use of corrosive and abrasive cleaning products, pads, and oven cleaner products. Chips, dents or cracks due to abuse, misuse, freight damage, or improper installation. Damage of product caused by accident, re, oods or act of God. The manufacturer and/or distributor/reseller is not liable for, and does not cover under warranty, any loss of properties or any costs associated with removing, servicing, installing, or determining the source of problems with this
product.
This warranty is valid in the country of the original purchase at retail. It is non-transferable and applies only to the original purchaser and does not extend to subsequent owners of this product. Any applicable implied warranties, including the war­ranty of merchantability, are limited in duration to a period of express warranty as provided herein beginning with the date of original purchase at retail and, no warranties, whether express or implied, shall apply to this product thereafter.
To obtain warranty service, you may contact your local reseller from which you purchased this product. Please conrm the terms of your local reseller’s policies prior to contacting. Typically, you must include product identication information, including model number and serial number with a detailed description of the problem you are experiencing. You must also include proof of the date of original retail purchase as evidence that the product is within the applicable warranty period.
The information in this document is subject to change without notice, please contact your local reseller for updated details.
Page 20
Page 22
Disclaimer
Carefully inspect all items for damages before accepting delivery. note any damages on the freight bill or express receipt. request name and signature of the carrier’s agent and keep copy to support your claim. Upon acceptance of items, owner assumes responsibility for its safe arrival. Report damages to the carrier and le a claim immediately. Failure to do so may result in the denial of your claim. The carrier will furnish you with necessary forms for ling a claim.
Damages caused during transit are not covered under our warranty. Please contact us to le an insurance claim.
Please inspect contents of package(s) carefully upon receiving! We must be notied of any damages and/or missing parts within ve (5) days upon your receipt of package(s). Claims will not be accepted after ve (5) days. NOTE: Items were thoroughly tested and carefully packed in our factory before shipping.
Products must be returned in good working condition with ALL original parts and documentation packed in ALL original cartons, llers and shipping cartons. A restocking fee of 15% will be charged for all approved return(s). Exchanges or returns may not be accepted if any packaging is missing.
Make sure to inspect the hood for damages and defects before installation. Appearance aws of the hood found after installation and not affecting hood performance is not covered under our warranty for returns or exchang­es. Service visits not covered under warranty will carry a service charge.
Before Installation: Return for exchange or refund (please see above for acceptable returns). After Installation: NO exchange or refund.
Contact Us
If you need any assistance, please contact your local reseller. Please have your order number and model of the range hood ready. This information will help them better respond to your request.
If you need replacement parts, we recommend that you only use genuine parts. Our accessories and parts are engineered and designed specically for this series of range hood, each is rigorously tested assuring the utmost in durability and reliability, providing a factory match, factory-installed appearance and functionality tailored to
each individual range hood model.
The information in this document is subject to change without notice, please contact your local reseller for updated details.
Page 21
Page 23
Your Notes
Page 22
Page 24
Cavaliere