Cavaliere AP238PS1330 Installation Manual

500 W Warner, Santa Ana CA 92707
Technical Support: 714-622-1550
cavalierehoods.com
Installation Manual
Important Safety Notice
Read all Instructions before Installing and operating this appliance
To reduce the risk of re, electric shock, or injury to persons:
For general ventilating use only. DO NOT use to exhaust hazardous or explosive materials and va­pors.
sure to vent air outside. DO NOT vent exhaust into spaces between walls, crawl spaces, ceiling, attics or garages.
den utilities.
vendor.
To reduce the risk of a stove top grease re:
Page 1
Important Safety Notice
Read all Instructions before Installing and operating this appliance
To reduce the risk of injury to persons in the event of a stove top grease re:
To reduce the risk of injury to persons in the event of a gas leaks:
Your safety and the safety of others is very important. We have provided many important safety mes­sages in this manual and on your appliance. Always read and obey all safety messages. All safety mes­sages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you
what can happen if the instructions are not followed.
WARNING
This is the safety alert symbol. This symbol alerts you to potential hazards that can hurt you and others. All safety messages will follow the safety alert symbol and the word “WARNING”.
The manufacturer and/or distributor/reseller declines all responsibility in the event of failure to ob­serve the instructions given here for installation, maintenance and suitable use of the product. The manufacturer and/or distributor/reseller further declines all responsibility for injury due to neg­ligence and the warranty of the unit automatically expires due to improper maintenance. The manufacturer and/or distributor/reseller will not be held responsible for any damages to per­sonal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood.
Page 2
Table of Contents
INSTALLATION
Tools needed....................................................3
Parts supplied...................................................4
Venting requirements.......................................5
Mount heights & clearance...........................5-6
Calculating vent system length.......................6
Venting methods..............................................7
Electrical requirements....................................8
Preparation......................................................9
Installation................................................10-11
Range hood operations.............................12-13
Tools needed:
USE AND CARE
Troubleshooting...........................................14
Use and care information...............................15
Specications..............................................15
Measurements & Diagrams......................16-21
MAINTENANCE
Cleaning.................................................22
Replacing the lter & light bulb.....................22
WARRANTY
Coverage & exceptions..................................23
Disclaimer & Contact Us...............................24
Marker or
pencil
Level
Utility knife
Powered
screwdriver or drill
Measuring tape
Flat-blade and Phillips
screwdrivers
Page 3
Parts supplied:
Upper Chimney
Lower Chimney
Chimney-mounting Bracket
Qty: 4 PCS
Qty: 6 PCS
Qty: 4 PCS (30-in models) Qty: 6 PCS (36-in models)
Range Hood
Qty: 2 PCS (30-in models) Qty: 3 PCS (36-in models)
Qty: 2 PCS (30-in models) Qty: 3 PCS (36-in models)
Bafe Filters
Qty: 4 PCS
Qty: 4 PCS
(For sheet rock only)
Page 4
Venting Requirements
Height & Clearance
Vent system must terminate to the outside • (roof or side wall). DO NOT terminate the vent system in an at-
tic or other enclosed area.
DO NOT use 4” (10.2 cm) laundry-type wall
caps.
Use metal/aluminum vent only. Rigid metal/
aluminum vent is recommended. DO NOT use plastic vent.
Always keep the duct clean to ensure proper • airow. Calculate the following gures before instal-• lation:
Distance from the oor to the ceiling.1. Distance between the oor to the coun-2.
tertop/stove (recommend* 27” to 30”). Distance between the countertop/stove 3.
to the range hood. Height of hood and duct cover.4.
For the most efcient & quiet operation:
A distance of 27” to 30” is recommended* • between stove top and the bottom of range
hood.
It is recommended that the range hood be • vented vertically through the roof through 6” (15.3 cm) or bigger round metal/aluminum vent work. The size of the vent should be uniform.• Use no more than three 90° elbows.• Make sure there is a minimum of 24” (61 • cm) of straight vent between the elbows if more than one elbow is used. DO NOT install two elbows together.• The length of vent system and number of • elbows should be kept to a minimum to pro­vide efcient performance. The vent system must have a damper. If • roof or wall cap has a damper, DO NOT use damper (if supplied) on top of the range
hood.
Use silver tape or duct tape to seal all joints • in the vent system. Use caulking to seal exterior wall or roof
opening around the cap.
Maximum ceiling clearance 110” at 30” hood mounting height above countertop/ stove (may vary with differ­ent model).
Min: 27” Max: 30”
Max: 110”
36” base
Chimney-
mounting
Bracket
Upper
Chimney
Lower
Chimney
Range hood
Countertop/Stove
* Due to different ceiling height congurations, rec-
ommended height may not be applicable.
Page 5
IMPORTANT:
A minimum of 6” round (standard for this range hood) or 3-1/4 x 10” rectangular duct (purchased separate-• ly) must be used to maintain maximum airow efciency. Always use rigid type metal/aluminum ducts if available to maximize airow when connecting to provided
duct.
Please use Duct Run Calculation below to compute total available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase • duct size from 6” to 7” or 8”. If a reducer is used, install a long reducer instead of a pancake reducer. Reduc­ing duct size will restrict airow and decrease airow, thus reduce duct size as far away from opening as possible. If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible.• Minimum mount height between stove top to hood bottom should be no less than 27-inch*.• Maximum mount height between stove top to hood bottom should be no higher than 30-inch*.• It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat • damage and re hazard; while hoods mounted too high will be hard to reach and will loose its performance and efciency. If available, also refer to stove top manufacturer’s height clearance requirements and recommended hood • mounting height above range.
* Due to different ceiling height congurations, recommended height may not be applicable.
Minimum Duct Size:
Round - 6” minimum• Rectangular - 3-1/4 x 10” minimum (requires a 6” to 3-1/4x10” adaptor, not supplied)
Calculating Vent System Length
To calculate the length of the system you need, deduct the equivalent feet for each vent piece used in the system from the recommended maximum duct run.
Duct Run Calculation:
Recommended maximum run
6” or 3-1/4 x 10” duct 50 ft
Vent piece deduction Each 90º elbow used 9 ft Each 45º elbow used 5 ft Each 6” to 3/14 x 10” transition used 7 ft Side wall cap with damper 0 ft Roof cap 0 ft
Duct Run Calcuation example:
One roof cap, two 90º elbow, and one 45º elbow used:
0ft + 9ft + 9ft + 5ft = 23ft used.
Deduct 23ft from 50ft, 27ft maximum available for
straight duct run.
Page 6
Venting Methods
This range hood is factory set for venting through the roof or wall.• Vent work can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed.
IMPORTANT:
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or • garages. All exhaust must be ducted to the outside. Use metal/aluminum duct work only. • Fasten all connections with sheet metal screws and tape all joints with certied Silver Tape or Duct Tape.• Use caulking to seal exterior wall or roof opening around the cap.
Horizontal wall venting
Option 1:
Option 2:
Side wall cap
Vertical roof venting
Roof cap
Page 7
Loading...
+ 19 hidden pages