This machine is intended for commercial use. It is
suited to scrub floors in an indoor environment and is
not constructed for any other use. Use only
recommended pads/brushes and cleaning solutions.
The following safety alert symbols are used throughout
this manual as indicated in their descriptions:
OPERATION
4. Before leaving or servicing machine:
–Turn off machine.
–Unplug cord from wall outlet.
5. When servicing machine:
–Unplug cord from wall outlet.
–Avoid moving parts. Do not wear loose
jackets, shirts, or sleeves.
–Use manufacturer supplied or approved
replacement parts.
WARNING: To warn of hazards or unsafe
practices which could result in severe personal
injury or death.
FOR SAFETY: To identify actions which must be
followed for safe operation of equipment.
The following information signals potentially dangerous
conditions to the operator or equipment:
FOR SAFETY:
1. Do not operate machine:
–Unless trained and authorized.
–Unless operator manual is read and
understood.
–In flammable or explosive areas unless
designed for use in those areas.
–Unless cord is properly grounded.
–With damaged cord or plug.
–If not in proper operating condition.
–In outdoor areas.
–In standing water.
2. Before operating machine:
–Make sure all safety devices are in place
and operate properly.
3. When using machine:
–Do not run machine over cord.
–Do not pull machine by plug or cord.
–Do not pull cord around sharp edges or
corners.
–Do not unplug by pulling on cord.
–Do not stretch cord.
–Do not handle plug with wet hands.
–Keep cord away from heated surfaces.
–Do not release handle grips until pad
comes to a complete stop.
–Go slow on inclines and slippery surfaces.
–Report machine damage or faulty
operation immediately.
WARNING: Hazardous Voltage. Shock or
electrocution can result. unplug machine before
servicing.
GROUNDING INSTRUCTIONS
Machine must be grounded. If it should
malfunction or breakdown, grounding provides a
path of least resistance for electrical current to
reduce the risk of electrical shock. This machine
is equipped with a cord having an
equipment–grounding conductor and grounding
plug. The plug must be plugged into an
appropriate outlet that is properly installed in
accordance with all local codes and ordinances.
Do not remove ground pin; if missing, replace
plug before use.
ATTENTION: Use caution when starting out.
Machine will jolt when triggers are pulled.
5
OPERATION
3. To move machine left (A), slightly lower handle. To
move right (B), slightly raise handle. Operate
machine with a side to side motion (Figure 10).
STORING MACHINE
1. Remove brush/pad driver from machine and neatly
coil cord around cord hook and handle.
2. Store in a dry area in the upright position.
3. For minimal storage or transport space, fold
handle down and position as shown
(Figure 11).
A
FIG. 10
4. To stop machine, release triggers and safety lock
button will automatically engage.
FOR SAFETY: When using machine, do not
release handle grips until pad comes to a
complete stop.
NOTE: Circuit breaker may trip under conditions of
excessive overload. Periodically check pad for soil
build–up. To reset circuit breaker switch, wait 15
seconds and push reset button at side of handle.
5. When finished scrubbing perform the following
maintenance procedures:
B
MACHINE MAINTENANCE
WARNING: Hazardous Voltage. Shock or
electrocution can result. Unplug machine before
servicing.
AFTER EACH USE:
FIG. 11
ATTENTION: Do not expose to rain. Store
indoors.
RECOMMENDED STOCK ITEMS
Refer to the Parts List section for recommended stock
items. Stock Items are clearly identified with a bullet
preceding the parts description (Figure 12).
1. Remove pad driver or brush.
2. Wash pads and brush.
3. Clean machine base.
4. Inspect power cord for damage, if worn or
damaged, replace immediately.
5. Wipe power cord with damp cloth and neatly coil
around cord hook and handle. To remove cord,
pull and turn cord hook upward.
6. Periodically check that all bolts and nuts are tight.
7. Every 250 hours of operation check motor carbon
brushes for wear. Replace brushes when 1 cm or
less in length.