Castel MAC E10, E15, T14/2, E20, T20 User guide

...
E5 E10 E15
B L A S T
C H I L L E R S
T14/2
E20
T20 T24 T30 T40 T50
INSTRUCTION MANUAL
Cod. 71503788/0 - 10/2010 - Rev. 02
GB
WW
WW
THE FOLLOWING OPERATIONS AND
THOSE HIGHLIGHTED BY THIS SYMBOL
MUST NOT BE PERFORMED BY THE
1. ELECTRICAL CONNECTIONS
2. WATER CONNECTIONS
AA
RR
RR
NNIIII
AA
APPLIANCE USER
NN
NN
GG !!!!!!!!!!!!
NN
GG
3. INSTALLATION
4. TESTING
5. REPAIRING MACHINE COMPONENTS
6.
DISASSEMBLY OF THE APPLIANCE AND/OR ITS COMPONENTS
7. ADJUSTMENTS AND CALIBRATION
8. CLEANING THE APPLIANCE AND MAINTENANCE OF:
- ELECTRICAL PARTS,
- ELECTRONIC PARTS,
- MECHANICAL PARTS,
- REFRIGERATION SYSTEM PARTS
32
GB
CONTENTS
1. GENERAL DOCUMENTATION
1.1 General information page 5
1.2 Installation page 5
1.3 Transport and handling page 5
1.4 Unpacking - disposal of packaging materials page 5
1.5 General safety regulations page 6
2. INSTALLATION
2.1 Data plate information page 6
2.2 Positioning page 6
2.3 Ambient temperature and air circulation page 7
2.4 Electrical connections page 7
2.5 Refrigeration component connections - remote assemblies page 7
2.6 Condensate drainage connection page 7
2.7 Information for the installation technician page 7
2.8 Safety and control systems page 8
2.9 Appliance disposal page 8
3. ADVICE TO ENSURE EFFICIENT APPLIANCE OPERATION
3.1 Shut-down procedures page 9
3.2 Operating tips page 9
3.2.1 Precooling page 9
3.2.2 Loading the appliance page 9
4. DESCRIPTION OF THE CONTROL PANEL page 10
4.1 Push-buttons page 11
5. PROGRAMMING AND OPERATING INSTRUCTIONS
5.1 Starting up the appliance page 12
5.2 Soft blast chilling by temperature page 12
5.3 Soft timed blast chilling page 14
Hard blast chilling page 14
5.4 Hard blast chilling by temperature page 14
5.5 Hard timed blast chilling page 15
5.6 Blast freezing by temperature page 16
5.7 Timed blast freezing page 17
33
GB
6 APPLIANCE FUNCTIONS
6.1 Date and time settings page 18
6.2 Ice cream surface hardening page 18
6.3 Muting the beeper and alarm reset page 18
6.4 Program storage page 18
6.5 Displaying the three latest HACCP alarms page 18
6.6 Printing out stored data page 18
6.7 Forced ventilation function page 19
6.8 User programming page 19
6.9 Manual defrosting page 19
6.10 Automatic defrost cycles page 19
7. ALARM MANAGEMENT
7.1 Storage of data/errors page 20
7.2 Alarms list page 20
8. MAINTENANCE AND CLEANING
8.1 General safety regulations page 22
8.2 Cleaning the condenser page 22
8.3 Cleaning the cell page 23
8.4 Defrost water drainage page 24
34
I
GB
1. GENERAL DOCUMENTATION
1.1. General information
• This manual is an integral part of the product, providing all the information required to ensure correct installation, operation and maintenance of the machine.
• Read the manual carefully, making refer­ence to it for machine operation. Keep the manual in a safe place where it can be accessed by all authorised operators (installers, operators and service per­sonnel). The machine has been constructed in compliance with the directives 73/23/CEE (low-voltage), 89/336/CEE (electromagnetic compatibility) and 98/37/CE (machines; for certain models only).
• The machine has been designed for pro­fessional applications only and should only be operated by qualified personnel.
• The machine must only be used for the purposes for which it was designed, i.e. for chilling and freezing food products.
The machine must not be used for prod-
ucts requiring constant temperature con­trol and recording, such as:
- heat-sensitive chemicals,
- medicines or
- blood products.
The manufacturer declines all responsibil-
ity for any damage caused by incorrect or unreasonable machine use, such as:
• improper use by untrained persons;
• technical modifications or operations not suited to specific models;
• use of non-original or non-specific spare parts;
• failure to follow the instructions given in this manual.
This appliance is not intended for use by per­sons -including children- with reduced physi­cal, sensory or mental capabilities, or lack of experience and knowledge, unless they have been fiven superfision or instruction concerning use of the appliance by a person responsible for their safeti. Children should
be supervised to ensure that they do not play with appliance.
1.2 Installation
The machine must be installed by a spe­cialised technician authorised by and in compliance with the instructions given in this manual. In the event that the machine is fitted with a remote condenser unit, the installation technician is responsible for checking all connections in compliance with the instructions given by for plant and machine installation.
1.3 Transport and handling
• To load or unload the machine and/or components from/onto the means of transport, use a lift truck or fork lift equipped with forks that are at least half the length of the machine housing; use a crane if the machine is fitted with eye bolts. Select the lifting equipment suited to the weight and overall dimensions of the packaged machine/components.
When handling the machine/ components,
• apply all precautions to prevent damage, in compliance with the information given on the packaging material (fig. 1).
1.4 Unpacking
• Remove all cardboard, wood or other materials from the wood base on which the machine is set. Lift the machine/components with suitable means (e.g. lift truck), remove the wood base, then position the machine/components in the allocated
35
site.
GB
• Once all packing material has been removed, check that the machine has not been dam­aged in any way.
• Remove the pro­tective PVC film on
the stainless steel panels from all internal and external sur­faces (fig. 2).
Always wear protective gloves when
handling packing material and the wood base.
• NB Dispose of packing materials in com­pliance with disposal regulations applied in the country where the machine is to be installed. Never dispose of materials in the environment.
.5 General safety regulations
1
Failure to observe the recommendations made by the present manual will be at the entire responsibility of the machine user. The main safety regulations are as follows:
- do not touch the machine with moist or wet hands or feet;
- never operate the machine while bare­foot;
- do not insert screwdrivers, cooking utensils or any other object between the guards and moving parts;
- before performing cleaning or routine maintenance operations, disconnect the machine from the power supply at the master switch and the main knife switch (if present);
- never pull on the power cable to dis­connect the machine from the power supply.
PERFORMED BY A CERTIFIED INSTALLATION
2. INSTALLATION
2.1 Data plate information
• Check that the data specified on the plate correspond to the characteristics of the power supply (V, kW, Hz, no. phas­es and power available).
• The dataplate with appliance specifica­tions is located at the rear exterior of the
machine and/or on the electrical boards (fig. 3).
The set-up of individual units and the
installation of condensers are subject to the fire-safety regulations of the country in which the machine is installed; seek all necessary advice from the local fire­fighting authorities. Bear in mind that the intervention of safe­ty valves or plug fuses in the refrigerat-
WWWWAAAARRRRNNNNIIIINNNNGGGG !!!!!!!!!!!!
THESE OPERATIONS MUST BE
TECHNICIAN ONLY.
ing circuit will lead to the immediate dis­charge of refrigerant into the environ­ment.
2.2 Positioning
• The machine must be installed and com­missioned in complete compliance with safety regulations, procedures and standing laws.
• The installation technician bears the responsibility of ensuring compliance with fire safety requirements; seek all necessary advice from the local fire­fighting authorities.
• Position the machine in the allocated site.
• Adjust the machine feet until the appli­ance is perfectly level. In the case of particularly heavy equipment, use appropriate lifting means
36
GB
(fig. 1).
• If the appliance is not perfectly level, cor­rect operation and condensate flow-off will not be assured.
AVOID
• direct exposure to sunlight;
• closed sites with high temperatures and poor air circulation;
• installing the machine near sources of heat (fig. 4).
.4 Electrical connections
2
A dedicated thermal-magnetic circuit breaker compliant with established regula­tions must be installed on the appliance power line.
• Connected electrical cables must corre­spond to the technical data (as specified on electrical drawings provided by the installation technician).
Connect the earthing conductor to an effi-
cient earthing system.
THE MANUFACTURER DECLINES ALL LIABILITY AND GUARANTEE OBLIGA­TIONS IN THE EVENT OF INJURY TO PERSONS OR DAMAGE TO EQUIP­MENT AND OBJECTS DUE TO INCOR­RECT INSTALLATION AND/OR FAILURE TO COMPLY WITH STANDING INSTAL­LATION REGULATIONS.
CONNECTING THE APPLIANCE TO THE POWER SUPPLY. In the event of damage to the power sup­ply cable on the appliance, have the cable replaced only by a qualified electrician to avoid any risk of personal injury.
2.3 Ambient temperature and air circu­lation
For air-cooled appliances, the maximum ambient temperature for operation is 32°C. Correct operation cannot be guaranteed at higher temperatures. The machine may operate safely to a max­imum temperature of 38°C. Remote condensing units must be installed in special rooms or outdoors, pro­tected against direct sunlight by a shelter or roof structure (at the cost of the pur­chaser). Sufficient air circulation must be guaran­teed at all times.
2.5 Refrigeration component connections - remote assemblies
Appliance power lines are sized for instal­lation distances of up to 10 metres. For greater distances, seek advice from .
2.6 Condensate drainage connection
Fit a condensate/wash water drainage hose with a minimum diameter of 1” (“Geberit” or similar type).
Provide a waste pipe with a trap with a diame­ter of at least 1 1/2” at floor level.
37
GB
.7 Information for the installation
2
technician
Before starting up the machine, check that it has been correctly installed and commis­sioned (test report).
1. Check that there are no gas leaks from weldings or joints made during installa­tion works.
2. Check that the pipes connecting the condenser to the remote condensing unit have been well insulated.
3. Check all wiring connections.
4. Check electrical input.
5. Check the standard pressure in the refrigerant system.
6. Check the water connections and effi­ciency of the pressure switch valve dur­ing operation, as well as the flow of con­densing water (in water-cooled units).
7. Perform at least one blast freezing cycle (to the SET temperature) and one manu­al defrosting cycle.
In the event that the appliance or the remote condensing unit have not been transported in a vertical position (e.g. on the back) or have been overturned during installation works, allow at least 4 hours before starting up the equipment.
• Inform the customer of the exact purpose of the appliance, with specific reference to the use and requirements of the cus­tomer.
The appliance must be installed and put into service by a technician authorised.
2.8 Safety and control systems
• Door microswitch: shuts down fan opera­tion in the cell when the door is opened.
• General fuses: protect the power circuit against short circuiting and overloads.
• Compressor heat relay: intervenes in the event of overloads or operating faults.
• Safety pressure switch: intervenes in the event of excessive pressure in the refrig­erant circuit.
• Plug fuses: intervene in the event of over­pressure or operating fault in the safety pressure switch (see above).
• Chamber temperature control: operated by the electronic board by means of a probe inside the cell.
• Temperature control end defrost cycle: controlled by the electronic board by means of the probe in the evaporator.
2.9 Disposal of waste electronic
and electrical equipment (WEEE) Fulfilling Directives 2002/95/CE, 2002/96/CE and 2003/108/CE on the dispo­sal of waste electronic and electrical equipment.
The crossed out wheeled bin sym­bol indicates the product must be collected separately from other waste when it has become redun­dant. Differentiated collection of this equipment is arranged and
handled by themanufacturer. Consequently, the user who is wanting to dispose of this equipment must contact the manufacturer and follow the method the lat­ter has adopted to allow separate collection of the redundant equipment. Appropriate differentiated collection for the subsequent recycling, treatment and eco­friendly disposal of the dismantled equip­ment prevents possible negative effects on the environment and health and facilitates the recycling of materials used in manufactu­ring the equipment. Administrative sanctions foreseen by the regulations in force shall be applied for any abusive disposal of the product by the hol­der.
38
GB
3. ADVICE TO ENSURE EFFICIENT APPLIANCE OPERATION
0.5 - 2cm.
3.1 Shut-down procedures
In the event of emergency, shut down the appliance by switching off power at the main panel, by means of the knife switch or by removing the plug from the power sock­et.
c) Position trays inside the tray compart-
ment as far as they will go, as close as
3.2 Operating tips
Before starting up the appliance, clean the inside of the cell thoroughly.
3.2.1 Pre-cooling
Before using the appliance for the first time, or after a prolonged period of disuse, pre-cool the cell by running an empty cycle until the set operating temperature has been reached. To ensure optimal performance without any alteration to food quality: arrange food products in such a way as to favour the cir­culation of cold air throughout the cell; open the door
as little as possible.
3.2.2 Loading the appliance a) Ensure that foods to be chilled and/or
frozen are separate and do not have a thickness greater than 50-80 mm. Do not load the appliance beyond the quantity recommended by the manufac­turer.
possible to the evaporator.
d) Position the core probe at the centre of
the largest product or food item; make sure that the tip of the probe does not protrude or touch the tray. The probe must be cleaned and sani­tised before each new cycle (operation) to prevent inadvertent contamination.
b) Ensure that there is sufficient clearance
between trays to enable free air circula­tion. If the appliance is not completely full, distribute the trays and foods evenly throughout the available space.
e) Avoid covering the trays and/or contain-
ers with insulating covers or film. The more the product is insulated, the more time is required for chilling or freezing. Trays must be packaged when the prod­uct has been chilled, before being placed in storage.
39
6
5
16
1
13
11
10
3
5a
4
5b
15
7
8
9
12
2
14
GB
4. DESCRIPTION OF THE VERTICAL CONTROL PANEL
40
Loading...
+ 22 hidden pages