Salvo Power Supply & Beacon (SPSB-US)
User Guide
The Salvo Power Supply converts 110/240V to 24VDC to power
the SCP+, pr oviding
a safer power
level at the user interface. The SPSB is mounted to the interior wall of the warehouse, adjacent to the Loading Bay and is combined with an Red/Green Beacon to provide notification that the Loading Bay has been activated and it is safe to open the bay door and commence loading or unloading.
Power Supply
Input
Voltage 100~240VAC (88V ~ 264VAC – Full Range)
Frequency 47 - 63Hz
Current <2A@115V and 1.2A@230V AC input, full load
Inrush Current <40A@230VAC input, Cold Start at 25°C ambient
Leakage Current <2.0mA@240VAC input
Output
Voltage 24V
Rated Load 0A
Range Load 3.2A
Output Tolerance +/- 1%
Line Regulation +/-0.5%
Load Regulation +/-0.5%
Ripple Noise MAX 120mV
Efciency (Typ) 85%
Power 76.8W
Specifications
Salvo Power Supply & Beacon
Order Information
Please advise correct part number when ordering.
(** mandatory information)
Part Number**
007269
U-Salvo-2013-E Issue 1
30
WARNING – Disconnect Electrical Supply Before Opening Unit
Means of Isolation should be located adjacent to the device and should be clearly marked and easily
accessible.
Installation of this equipment, other than for its specied use, may impair the operation and safety integrity
of this product.
Precautions
Enclosure
Material RAL 7035 Grey Polycarbonate – IEC 60695-1-2
Dimensions 205mm(W) 220mm(H) 140mm(D)
Mounting Details 94mm(W) 90mm(H) – M5
Operating Temperature -25°C to +115°C
Shock Resistance 20 Joules (IK10)
Ingress Protection IP65
Specifications
Beacon
Material White Polycarbonate
Dimensions Ø85mm x 81mm(H)
Voltage 11/35VDC
Current 50mA
Operating Temperature -20°C to +70°C
Ingress Protection IP65
Cable Entry Size M20 x 2
Salvo Power Supply & Beacon (SPSB-US)
User Guide
Installation should be carried out by a competent and qualied person who has read and understood these instructions. Any electrical installation must comply with standard “BS7671 – Requirements for Electrical Installations”, commonly referred to as the IEE Wiring Regulations, or any particular regulations and practices, specied by the local electricity supply company at the time of installation. Installation
must be carried out by competent personnel qualied to IEE 17th Edition or any equivalent regulations in
force at the time of installation.