CASE STX Steiger 350/400/450/500/550/600 Fault Codes list
Fault Code list ordered by Control Module
1002 - Short circuit to 12 V or malfunction of the winding chain of the lift valve
hitch
1003 - Electromagnet lifting hitch: open circuit or short circuit to ground
1004 - Short to 12 V windings of the valve of lowering of a coupling device
1005 - Winding of the lowering valve of the coupling device - short to ground or
chain termination
1006 - Stimulation of the exciter of low voltage electronic traction control in view of
his refusal
1007 - Error checking low voltage exciter control module
1008 - The low-voltage side of the lifting electromagnet is connected to the "mass"
1009 - The low-voltage side of the lowering solenoid is connected to the "mass"
1011 - The tractor control unit is disconnected from the CAN bus
1012 - Loss of communication with the armrest controller
1013 - Loss of communication with the instrument controller
1014 - Reference voltage 5 V exceeds the upper permissible limit
1015 - Reference voltage 5 V below the lower limit
1017 - Faulty position control potentiometer
1018 - The balance axle potentiometer signal is outside the normal range
working range
1019 - Failure of top-end potentiometer
1021 - Load potentiometer failure
1024 - Loss of communication with the instrument controller
1025 - Failure of the hoisting / lowering switch
1026 - Failure of the lift / lower switch on the wing
1028 - Failure of motion control potentiometer
1029 - Failure of the lowering speed adjustment potentiometer
1032 - Wrong driving speed. The value obtained from the data bus indicates
malfunction
1033 - Failure of the slip adjustment switch
1034 - Failure of the slip-on switch
1035 - Incorrect percentage of slippage
1036 - The armrest controller signaled a malfunction of the slow switch
lifting traction
1037 - Failure of the slow-down switch
1065 - The armrest controller determined that the tractor is not equipped with a system
traction control, but found traction contacts
1066 - Engine speed too low to calibrate the lower coupling
devices
1067 - The possibility of adjusting the thrust is provided, but the thrust contact sensor (s)
could not be detected
1068 - Throttle adjustment calibration interrupted due to tractor movement
1069 - Calibration of electronic traction control interrupted due to low speed
the engine
1071 - Pulse width modulation (PWM) growth threshold during calibration too
tall
1072 - Pulse width modulation (PWM) growth threshold during calibration too
low
1074 - The clutch potentiometer signal is outside the expected range when
the maximum raised position of the coupling device
1075 - Throttle lowering valve response threshold during calibration
too high
1076 - PWM lower threshold is too low
1077 - The operator did not respond to the electronic traction control calibration procedure
1078 - The coupler is not in the minimum lowered position
1079 - The range of the hitch is not in accordance with the specification
1080 - Ratio of hitch and range of commands
position control does not meet the allowable limits
1085 - Calibration of electronic traction control system required
1086 - There is no communication with the performance monitor (instrumentation controller)
1087 - Reference voltage 8 V above 8,8 V
1088 - Reference voltage 8 V below 7.2 V
1089 - Supply of voltage 12VH1 to the towing and lowering windings of the coupling device
below 8 V
14002 - The oil filter sensor in the gearbox is closed to earth when it is switched on
supply
14003 - The oil filter sensor of the hydraulic system closes to ground when
power on
14005 - Faulty shaft speed sensor error
14006 - Engine speed error GOV
14007 - Engine speed limit exceeded
14008 - Engine oil pressure sensor error
14009 - Engine operating hours lost
14010 - The IOM controller is disconnected from the network
14011 - Total loss of communication
14013 - The gearbox is disconnected from the mains
14014 - Engine coolant temperature sensor error
14015 - Engine Inlet Air Temperature Sensor Error
14016 - Engine shutdown procedure activated
14017 - The fuel level sensor voltage is below the permissible range
14018 - The GOV is disconnected from the network
14019 - The automatic temperature control system is disconnected from the network
14020 - Loss of CAN messages sent by the auxiliary system controller
steering system
14021 - Auxiliary steering is present, but no CAN messages received
15500 - Low pressure primary steering system - auxiliary
steering system works
15501 - High pressure assist steering system when
idle pump
15502 - Low pressure primary steering system - auxiliary
the steering system is faulty
15510 - Increased pressure of the primary steering system pressure sensor
management
15512 - Undervoltage of the pressure sensor of the primary steering system
management
15520 - Error in checking the pressure of the auxiliary control pump
15530 - Increased voltage of the auxiliary steering system pressure sensor
management
15532 - Undervoltage of the auxiliary steering system pressure sensor
management
15540 - Auxiliary system bypass electrical circuit rupture
steering system
15544 - Short circuit to + BAT of the solenoid of the bypass valve
auxiliary control system
15550 - Short circuit to the "mass" of the auxiliary system bypass solenoid
steering system
15552 - Short circuit to + BAT of the pump relay of the auxiliary steering system
management
15553 - Open circuit of the pump drive relay
15554 - Short to ground of the auxiliary pump relay of the steering pump
15560 - Voltage monitoring device VF3
15580 - No pressure was produced in the assist steering system
15590 - No auxiliary steering system equipment found
15591 - The battery voltage is insufficient to start the auxiliary pump
steering systems
15592 - The battery voltage is insufficient to start the auxiliary pump
steering systems
15994 - The engine is running, and the crankshaft rotation input signal is constantly
high level
18007 - Multi-function lever - switch error
18010 - Throttle valve Powershift - too low voltage
18011 - Throttle valve Powershift - too high voltage
18012 - Rotor variator speed switch error (CVT)
18015 - Rear position adjustment potentiometer - too
high voltage
18016 - Backward linkage traction control potentiometer - too low
voltage
18017 - Rear traction control potentiometer - too high
voltage
18018 - Rear linkage potentiometer - too low
voltage
18019 - Rear hitch height potentiometer - too high
voltage
18020 - Quick-lowering potentiometer for rear hitch - too low
voltage
18021 - Potentiometer for quick lowering of the rear hitch - too high
voltage
18022 - Rear suspension adjustment potentiometer Too low voltage
18023 - Rear suspension adjustment potentiometer too high a voltage
18024 - Error of position of the code flow sensor EHR (remote valve
management)
18025 - Back wheel slip adjustment potentiometer Too low voltage
18026 - Rear linkage slip adjustment potentiometer too high a voltage
18027 - EHR lever position (remote control valve) 5 - too low
voltage
18028 - EHR lever position (remote control valve) 5 - too high
voltage
18029 - EHR lever position (remote control valve) 6 - too low
voltage
18030 - EHR lever position (remote control valve) 6 - too high
voltage
18040 - EHR lever position (remote control valve) 1 - too low
voltage
18041 - EHR lever position (remote control valve) 1 - too high
voltage
18042 - EHR lever position (remote control valve) 2 - too low
voltage
18043 - EHR lever position (remote control valve) 2 - too high
voltage
18044 - EHR lever position (remote control valve) 3 - too low
voltage
18045 - EHR lever position (remote control valve) 3 - too high
voltage
18046 - Error of lateral swing control switch EHR (remote valve
management)
18047 - EHR lever position (remote control valve) 4 - too low
voltage
18048 - EHR lever position (remote control valve) 4 - too high
voltage
18049 - Control lever 1, X axis - Undervoltage
18050 - Control lever 1, X axis - too high voltage
18051 - Control lever 1, Y axis too low voltage
18052 - Control lever 1, Y axis too high voltage
18053 - Control lever 1, proportional rocker switch - too low
voltage
18054 - Control lever 1, proportional rocker switch - too
high voltage
18055 - Control lever 2, X axis too low voltage
18056 - Control lever 2, X axis too high voltage
18057 - Control lever 2, Y axis too low voltage
18058 - Control lever 2, Y axis too high voltage
18059 - Control lever 2, proportional rocker switch - too low
voltage
18060 - Control lever 2, proportional rocker switch - too
high voltage
18061 - Reference voltage - short circuit to 0 V
18062 - Reference voltage - short circuit to 12 V
18063 - EEPROM error
18064 - Multifunction lever communication error (MFH)
18065 - Basic check error of multifunction lever (MFH)
18066 - Error of lever invalidation (remote control valve) 1
18067 - Error of lever invalidation (remote control valve) 2
18068 - Error of lever invalidation (remote control valve) 3
18069 - Error of lever invalidation (remote control valve) 4
18070 - Error of lever invalidation (remote control valve) 5
18071 - Failed lever invalid signal (remote control valve) 6
18072 - EDC Mouse Up / Malfunction Switch Malfunction
19001 - Reading battery voltage (electrical) - high signal value - by
the battery voltage rating P0563 is exceeded the upper limit value
19002 - Reading battery voltage (electrical) - low signal value - by
battery voltage estimation P0562 the lower limit value is not reached
19010 - Temperature sensor after neutralizer (electrical)
19011 - Temperature sensor after neutralizer (electrical)
19019 - Temperature sensor in front of the neutralizer (electrical) - high signal value
- high value on the circuit of the neutralizer temperature sensor P0428
19020 - Temperature sensor before neutralizer (electric) - low signal value Low value on the circuit of the neutralizer temperature sensor P0427
19037 - Supply of sensor 2 (internal 5 V circuit, urea pressure sensors) - too
high supply voltage - reagent P204D - pressure sensor - short circuit on
high voltage source
19038 - Supply of sensor 2 (internal 5 V circuit, urea pressure sensors) - too
low supply voltage - reagent P204C - pressure sensor - short to low voltage source
19046 - Urea pressure sensor in the unit (electrical) - voltage failure
power supply - Reagent P204A - pressure sensor - open circuit
19047 - Urea pressure sensor in the unit (electrical) - high signal level - Reagent
P204D - pressure sensor - short to high voltage source
19048 - Urea pressure sensor in the unit (electrical) - low signal level - Reagent
P204C - pressure sensor - short to low voltage source
19055 - Urea pressure sensor in the unit (electrical) - high signal level - reagent
P2045 - Pump module temperature sensor - short to high voltage source
19056 - Urea pressure sensor in the unit (electrical) - low signal level - reagent
P2044 - Pump module temperature sensor - short to low voltage source
19064 - Supply voltage of internal heaters 1 (UB1), electric. - breaking the circuit UB1
- pump module P20C5 - internal heating - chain breaking
19065 - Supply voltage of internal heaters 1 (UB1), electric. - a short
short circuit for power supply of the battery at UB1, switch 15 in position Off - module
pump P20C8 - internal heating - short circuit to a high source
stresses
19073 - Supply voltage 2 - tubular heaters (UB2), electric. - closure on
battery power with UB2 and disconnected key 15 - reagent P20C4 - preheating
suction pipe - short to high voltage source
19074 - Supply voltage 2 - tubular heaters (UB2), electric. - open circuit UB2 Reagent P20C1 - preheating the suction pipe - breaking the chain
19075 - Supply voltage 2 - tubular heaters (UB2), electric. - closure on
"mass" UB2 - Reagent P20C3 - preheating the suction pipe - breaking the chain
19082 - Supply voltage 3 - coolant control valve and valve
reversing mechanism (UB3), electric. - short to battery UB3 with key 15
in the "off" position (off) - P20A3 vapor escape valve (control valve
Air conditioner) - short circuit to a high voltage source
19083 - Supply voltage 3 - coolant control valve and valve
reversing mechanism (UB3), electric. - open circuit UB3 - Vapor extraction valve P20A0
(the control valve of the air-reducing agent) - breaking the chain
19084 - Supply voltage 3 - coolant control valve and valve
reversing mechanism (UB3), electric. - short circuit to earth "UB3 - tap valve
vapor P20A2 (control valve of the air conditioner) - short to the source
low voltage
19091 - Voltage monitoring VDD11 / VDD25 - Dosing valve / pump motor
- low supply voltage VD11 - P0659, supply voltage 12 V for the module
dosing - the lower limit value is not reached
19092 - Voltage monitoring VDD11 / VDD25 - Dosing valve / pump motor
- high supply voltage VD11 - P0658, supply voltage 12 V for the module
dosing - the lower limit value has been exceeded
19100 - Urea level sensor (electrical) - supply voltage error - level sensor
P203E - unreliable / unstable circuit
19101 - Urea level sensor (electrical) - high signal level - P203D reagent level sensor in the tank - short to high voltage source
19102 - Urea level sensor (electrical) - low signal level - P203C reagent level sensor in the tank - short to low voltage source
19109 - Urea temperature sensor in the tank (electrical) - high signal level reagent P205D - temperature sensor in the tank (reagent temperature - solution in the tank)
-
short circuit to a high voltage source
19110 - Urea temperature sensor in the tank (electric) - low signal level - reagent
P205C - temperature sensor in the tank (reagent temperature - solution in the tank) - short
short to low voltage
19145 - Dosing valve (electrical) - short to positive terminal
battery - Rejector nozzle P2049 - short to high voltage source
19146 - Dosing valve (electrical) - short circuit to earth - injector
P2048 - short to low voltage source
19147 - Dosing valve (electrical)
19148 - Dosing valve (electrical) - metering valve permanently on
(detected as a result of the output of a rapidly disappearing error) - reagent P209B pressure in
dosing valve nozzle too high
19154 - Urea pump speed - the pump motor is disconnected - The pump does not feed
reagent P208B
19155 - Speed of the urea pump - blocking of the pump motor - pump
reagent P208A
19156 - Urea pump speed - permissible speed exceeded
pump - exceeding the permissible frequency of the pump of the reagent P208D
19157 - Urea pump speed - Hall sensor defective - The pump does not feed
reagent P208B
19163 - Short circuit of the cooling control valve for voltage
battery (UBat) or open load - short to battery - tap valve
vapor P20A3 (control valve purge reductant) - short circuit to
high voltage source
19164 - Short circuit of the cooling control valve for voltage
battery or open load - open load - vapor outlet valve P20A0
(control valve of the air conditioner) - open circuit
19181 - Reversing valve (4-2-way valve) Electric. - short circuit to
battery - vapor outlet valve P20A3 (control valve of the air reducer) short circuit to a high voltage source
19182 - Reversing valve (4-2-way valve), electric. - short circuit to
"mass" - the vapor outlet valve P20A2 (control valve of the air reducer) short to low voltage source
19183 - The reversing valve (4-2-way valve) electric. - open load the vapor outlet valve P20A3 (control valve of the air reducer) - an open circuit
19262 - Tank heating valve - Short to battery - Reagent P20B4 tank heating valve - short to high voltage source
19263 - Tank heating valve - short circuit to earth - reagent P20B3 - valve
tank heating - short to low voltage source
19264 - Tank heating valve - Open load - Reagent P20B1 - Tank heating valve
- open load
19265 - Tank heating valve - short circuit to earth - reagent P20B3 - valve
tank heating - short to low voltage source
19289 - The temperature at the outlet of the neutralizer is too low - the temperature after
neutralizer - physical. (error of the neutralizer heating time) - range / operation
P042B Neutralizer Temperature Sensor Circuit
19298 - Urea pressure too low when starting the system
19307 - Urea pressure too high - Urea pressure not reliable
(urea pressure too high) - Reagent P204B - Pressure above the limit
meanings
19316 - The temperature of the URE in the pump unit is outside the permissible range
range
19325 - The temperature of the URE in the tank is outside the permissible range