CASE STX Steiger 350/400/450/500/550/600 Fault Codes list
Fault Code list ordered by Control Module
1002 - Short circuit to 12 V or malfunction of the winding chain of the lift valve hitch 1003 - Electromagnet lifting hitch: open circuit or short circuit to ground 1004 - Short to 12 V windings of the valve of lowering of a coupling device 1005 - Winding of the lowering valve of the coupling device - short to ground or chain termination 1006 - Stimulation of the exciter of low voltage electronic traction control in view of his refusal 1007 - Error checking low voltage exciter control module 1008 - The low-voltage side of the lifting electromagnet is connected to the "mass" 1009 - The low-voltage side of the lowering solenoid is connected to the "mass" 1011 - The tractor control unit is disconnected from the CAN bus 1012 - Loss of communication with the armrest controller 1013 - Loss of communication with the instrument controller 1014 - Reference voltage 5 V exceeds the upper permissible limit 1015 - Reference voltage 5 V below the lower limit 1017 - Faulty position control potentiometer 1018 - The balance axle potentiometer signal is outside the normal range working range 1019 - Failure of top-end potentiometer 1021 - Load potentiometer failure 1024 - Loss of communication with the instrument controller 1025 - Failure of the hoisting / lowering switch 1026 - Failure of the lift / lower switch on the wing 1028 - Failure of motion control potentiometer 1029 - Failure of the lowering speed adjustment potentiometer 1032 - Wrong driving speed. The value obtained from the data bus indicates malfunction 1033 - Failure of the slip adjustment switch 1034 - Failure of the slip-on switch 1035 - Incorrect percentage of slippage 1036 - The armrest controller signaled a malfunction of the slow switch lifting traction 1037 - Failure of the slow-down switch 1065 - The armrest controller determined that the tractor is not equipped with a system traction control, but found traction contacts 1066 - Engine speed too low to calibrate the lower coupling devices 1067 - The possibility of adjusting the thrust is provided, but the thrust contact sensor (s) could not be detected 1068 - Throttle adjustment calibration interrupted due to tractor movement 1069 - Calibration of electronic traction control interrupted due to low speed the engine 1071 - Pulse width modulation (PWM) growth threshold during calibration too tall 1072 - Pulse width modulation (PWM) growth threshold during calibration too low 1074 - The clutch potentiometer signal is outside the expected range when
the maximum raised position of the coupling device 1075 - Throttle lowering valve response threshold during calibration too high 1076 - PWM lower threshold is too low 1077 - The operator did not respond to the electronic traction control calibration procedure 1078 - The coupler is not in the minimum lowered position 1079 - The range of the hitch is not in accordance with the specification 1080 - Ratio of hitch and range of commands position control does not meet the allowable limits 1085 - Calibration of electronic traction control system required 1086 - There is no communication with the performance monitor (instrumentation controller) 1087 - Reference voltage 8 V above 8,8 V 1088 - Reference voltage 8 V below 7.2 V 1089 - Supply of voltage 12VH1 to the towing and lowering windings of the coupling device below 8 V 14002 - The oil filter sensor in the gearbox is closed to earth when it is switched on supply 14003 - The oil filter sensor of the hydraulic system closes to ground when power on 14005 - Faulty shaft speed sensor error 14006 - Engine speed error GOV 14007 - Engine speed limit exceeded 14008 - Engine oil pressure sensor error 14009 - Engine operating hours lost 14010 - The IOM controller is disconnected from the network 14011 - Total loss of communication 14013 - The gearbox is disconnected from the mains 14014 - Engine coolant temperature sensor error 14015 - Engine Inlet Air Temperature Sensor Error 14016 - Engine shutdown procedure activated 14017 - The fuel level sensor voltage is below the permissible range 14018 - The GOV is disconnected from the network 14019 - The automatic temperature control system is disconnected from the network 14020 - Loss of CAN messages sent by the auxiliary system controller steering system 14021 - Auxiliary steering is present, but no CAN messages received 15500 - Low pressure primary steering system - auxiliary steering system works 15501 - High pressure assist steering system when idle pump 15502 - Low pressure primary steering system - auxiliary the steering system is faulty 15510 - Increased pressure of the primary steering system pressure sensor management 15512 - Undervoltage of the pressure sensor of the primary steering system management 15520 - Error in checking the pressure of the auxiliary control pump 15530 - Increased voltage of the auxiliary steering system pressure sensor management 15532 - Undervoltage of the auxiliary steering system pressure sensor management 15540 - Auxiliary system bypass electrical circuit rupture steering system 15544 - Short circuit to + BAT of the solenoid of the bypass valve
auxiliary control system 15550 - Short circuit to the "mass" of the auxiliary system bypass solenoid steering system 15552 - Short circuit to + BAT of the pump relay of the auxiliary steering system management 15553 - Open circuit of the pump drive relay 15554 - Short to ground of the auxiliary pump relay of the steering pump 15560 - Voltage monitoring device VF3 15580 - No pressure was produced in the assist steering system 15590 - No auxiliary steering system equipment found 15591 - The battery voltage is insufficient to start the auxiliary pump steering systems 15592 - The battery voltage is insufficient to start the auxiliary pump steering systems 15994 - The engine is running, and the crankshaft rotation input signal is constantly high level 18007 - Multi-function lever - switch error 18010 - Throttle valve Powershift - too low voltage 18011 - Throttle valve Powershift - too high voltage 18012 - Rotor variator speed switch error (CVT) 18015 - Rear position adjustment potentiometer - too high voltage 18016 - Backward linkage traction control potentiometer - too low voltage 18017 - Rear traction control potentiometer - too high voltage 18018 - Rear linkage potentiometer - too low voltage 18019 - Rear hitch height potentiometer - too high voltage 18020 - Quick-lowering potentiometer for rear hitch - too low voltage 18021 - Potentiometer for quick lowering of the rear hitch - too high voltage 18022 - Rear suspension adjustment potentiometer ­Too low voltage 18023 - Rear suspension adjustment potentiometer ­too high a voltage 18024 - Error of position of the code flow sensor EHR (remote valve management) 18025 - Back wheel slip adjustment potentiometer ­Too low voltage 18026 - Rear linkage slip adjustment potentiometer ­too high a voltage 18027 - EHR lever position (remote control valve) 5 - too low voltage 18028 - EHR lever position (remote control valve) 5 - too high voltage 18029 - EHR lever position (remote control valve) 6 - too low voltage 18030 - EHR lever position (remote control valve) 6 - too high voltage 18040 - EHR lever position (remote control valve) 1 - too low voltage
18041 - EHR lever position (remote control valve) 1 - too high voltage 18042 - EHR lever position (remote control valve) 2 - too low voltage 18043 - EHR lever position (remote control valve) 2 - too high voltage 18044 - EHR lever position (remote control valve) 3 - too low voltage 18045 - EHR lever position (remote control valve) 3 - too high voltage 18046 - Error of lateral swing control switch EHR (remote valve management) 18047 - EHR lever position (remote control valve) 4 - too low voltage 18048 - EHR lever position (remote control valve) 4 - too high voltage 18049 - Control lever 1, X axis - Undervoltage 18050 - Control lever 1, X axis - too high voltage 18051 - Control lever 1, Y axis too low voltage 18052 - Control lever 1, Y axis too high voltage 18053 - Control lever 1, proportional rocker switch - too low voltage 18054 - Control lever 1, proportional rocker switch - too high voltage 18055 - Control lever 2, X axis too low voltage 18056 - Control lever 2, X axis too high voltage 18057 - Control lever 2, Y axis too low voltage 18058 - Control lever 2, Y axis too high voltage 18059 - Control lever 2, proportional rocker switch - too low voltage 18060 - Control lever 2, proportional rocker switch - too high voltage 18061 - Reference voltage - short circuit to 0 V 18062 - Reference voltage - short circuit to 12 V 18063 - EEPROM error 18064 - Multifunction lever communication error (MFH) 18065 - Basic check error of multifunction lever (MFH) 18066 - Error of lever invalidation (remote control valve) 1 18067 - Error of lever invalidation (remote control valve) 2 18068 - Error of lever invalidation (remote control valve) 3 18069 - Error of lever invalidation (remote control valve) 4 18070 - Error of lever invalidation (remote control valve) 5 18071 - Failed lever invalid signal (remote control valve) 6 18072 - EDC Mouse Up / Malfunction Switch Malfunction 19001 - Reading battery voltage (electrical) - high signal value - by the battery voltage rating P0563 is exceeded the upper limit value 19002 - Reading battery voltage (electrical) - low signal value - by battery voltage estimation P0562 the lower limit value is not reached 19010 - Temperature sensor after neutralizer (electrical) 19011 - Temperature sensor after neutralizer (electrical) 19019 - Temperature sensor in front of the neutralizer (electrical) - high signal value
- high value on the circuit of the neutralizer temperature sensor P0428 19020 - Temperature sensor before neutralizer (electric) - low signal value ­Low value on the circuit of the neutralizer temperature sensor P0427
19037 - Supply of sensor 2 (internal 5 V circuit, urea pressure sensors) - too high supply voltage - reagent P204D - pressure sensor - short circuit on high voltage source 19038 - Supply of sensor 2 (internal 5 V circuit, urea pressure sensors) - too low supply voltage - reagent P204C - pressure sensor - short to low voltage source 19046 - Urea pressure sensor in the unit (electrical) - voltage failure power supply - Reagent P204A - pressure sensor - open circuit 19047 - Urea pressure sensor in the unit (electrical) - high signal level - Reagent P204D - pressure sensor - short to high voltage source 19048 - Urea pressure sensor in the unit (electrical) - low signal level - Reagent P204C - pressure sensor - short to low voltage source 19055 - Urea pressure sensor in the unit (electrical) - high signal level - reagent P2045 - Pump module temperature sensor - short to high voltage source 19056 - Urea pressure sensor in the unit (electrical) - low signal level - reagent P2044 - Pump module temperature sensor - short to low voltage source 19064 - Supply voltage of internal heaters 1 (UB1), electric. - breaking the circuit UB1
- pump module P20C5 - internal heating - chain breaking 19065 - Supply voltage of internal heaters 1 (UB1), electric. - a short short circuit for power supply of the battery at UB1, switch 15 in position Off - module pump P20C8 - internal heating - short circuit to a high source stresses 19073 - Supply voltage 2 - tubular heaters (UB2), electric. - closure on battery power with UB2 and disconnected key 15 - reagent P20C4 - preheating suction pipe - short to high voltage source 19074 - Supply voltage 2 - tubular heaters (UB2), electric. - open circuit UB2 ­Reagent P20C1 - preheating the suction pipe - breaking the chain 19075 - Supply voltage 2 - tubular heaters (UB2), electric. - closure on "mass" UB2 - Reagent P20C3 - preheating the suction pipe - breaking the chain 19082 - Supply voltage 3 - coolant control valve and valve reversing mechanism (UB3), electric. - short to battery UB3 with key 15 in the "off" position (off) - P20A3 vapor escape valve (control valve Air conditioner) - short circuit to a high voltage source 19083 - Supply voltage 3 - coolant control valve and valve reversing mechanism (UB3), electric. - open circuit UB3 - Vapor extraction valve P20A0 (the control valve of the air-reducing agent) - breaking the chain 19084 - Supply voltage 3 - coolant control valve and valve reversing mechanism (UB3), electric. - short circuit to earth "UB3 - tap valve vapor P20A2 (control valve of the air conditioner) - short to the source low voltage 19091 - Voltage monitoring VDD11 / VDD25 - Dosing valve / pump motor
- low supply voltage VD11 - P0659, supply voltage 12 V for the module dosing - the lower limit value is not reached 19092 - Voltage monitoring VDD11 / VDD25 - Dosing valve / pump motor
- high supply voltage VD11 - P0658, supply voltage 12 V for the module dosing - the lower limit value has been exceeded 19100 - Urea level sensor (electrical) - supply voltage error - level sensor P203E - unreliable / unstable circuit 19101 - Urea level sensor (electrical) - high signal level - P203D reagent ­level sensor in the tank - short to high voltage source 19102 - Urea level sensor (electrical) - low signal level - P203C reagent ­level sensor in the tank - short to low voltage source 19109 - Urea temperature sensor in the tank (electrical) - high signal level ­reagent P205D - temperature sensor in the tank (reagent temperature - solution in the tank)
-
short circuit to a high voltage source 19110 - Urea temperature sensor in the tank (electric) - low signal level - reagent P205C - temperature sensor in the tank (reagent temperature - solution in the tank) - short short to low voltage 19145 - Dosing valve (electrical) - short to positive terminal battery - Rejector nozzle P2049 - short to high voltage source 19146 - Dosing valve (electrical) - short circuit to earth - injector P2048 - short to low voltage source 19147 - Dosing valve (electrical) 19148 - Dosing valve (electrical) - metering valve permanently on (detected as a result of the output of a rapidly disappearing error) - reagent P209B ­pressure in dosing valve nozzle too high 19154 - Urea pump speed - the pump motor is disconnected - The pump does not feed reagent P208B 19155 - Speed of the urea pump - blocking of the pump motor - pump reagent P208A 19156 - Urea pump speed - permissible speed exceeded pump - exceeding the permissible frequency of the pump of the reagent P208D 19157 - Urea pump speed - Hall sensor defective - The pump does not feed reagent P208B 19163 - Short circuit of the cooling control valve for voltage battery (UBat) or open load - short to battery - tap valve vapor P20A3 (control valve purge reductant) - short circuit to high voltage source 19164 - Short circuit of the cooling control valve for voltage battery or open load - open load - vapor outlet valve P20A0 (control valve of the air conditioner) - open circuit 19181 - Reversing valve (4-2-way valve) Electric. - short circuit to battery - vapor outlet valve P20A3 (control valve of the air reducer) ­short circuit to a high voltage source 19182 - Reversing valve (4-2-way valve), electric. - short circuit to "mass" - the vapor outlet valve P20A2 (control valve of the air reducer) ­short to low voltage source 19183 - The reversing valve (4-2-way valve) electric. - open load ­the vapor outlet valve P20A3 (control valve of the air reducer) - an open circuit 19262 - Tank heating valve - Short to battery - Reagent P20B4 ­tank heating valve - short to high voltage source 19263 - Tank heating valve - short circuit to earth - reagent P20B3 - valve tank heating - short to low voltage source 19264 - Tank heating valve - Open load - Reagent P20B1 - Tank heating valve
- open load 19265 - Tank heating valve - short circuit to earth - reagent P20B3 - valve tank heating - short to low voltage source 19289 - The temperature at the outlet of the neutralizer is too low - the temperature after neutralizer - physical. (error of the neutralizer heating time) - range / operation P042B Neutralizer Temperature Sensor Circuit 19298 - Urea pressure too low when starting the system 19307 - Urea pressure too high - Urea pressure not reliable (urea pressure too high) - Reagent P204B - Pressure above the limit meanings 19316 - The temperature of the URE in the pump unit is outside the permissible range range 19325 - The temperature of the URE in the tank is outside the permissible range