CASAL C6P Instruction Manual

1
INDEX
2
PR ODU CT CONTAI NS
FO REW ORD
Mul ti-Fu nctio nal Swi tch
*Sel ect: tu rn left /righ t *Ent er/Se t: pres s
C6P AC/DC Charger x1
Char ge Cabl e x1
Ins truct ion Man ual x1
Bala nce Soc ket ada pter x1
128 x64 Pix el LCD Sc reen
Coo ling Fa n
Bal ance Po rt
Tempe ratur e Senso r Port
DC In put Soc ket
Cha rge Out put Soc ket
Below items are included in the package, contact your supplier if any item is miss.
AC inp ut Cabl e x1
W e t ha n k yo u f or pur chas ing CRC C6 P 10A/ 100W 11-18 V DC
AC In put Soc ket
We thank you for purchasing CRC C6P 10A/100W 110-230V/50Hz AC 11-18V DC balance charger/discharger. For your convenience and safety, please read this manual carefully before using this product.
CRC C6P AC/DC is a professional and high efficiency balance charger/discharger which is especially designed for charging/discharging LiPo , LiFe, LiIo, NiMH,NiCd and PB batteries.
3 4
SP ECI FICATION
OP TIO NAL ACCESSORIES
2x3 S in seri es Adapt er
FE ATURES
High efficiency power conversion circuit. Special advanced charging technology ensure a fast and precision charging performance.
The CRC balance charger series has a integrated cell balancer which can be expecially used for charging the LiPo, Lilo, LiFe batteries.
10 battery profile memories, 1 default memory of latest profile, 9 custom memories can be set and load by the user.
128x64 pixel LCD screen shows rich information: total current, total voltage, charge capacity (mAh), charge time, temperature, cell voltage, cell voltage difference etc.
Various functional settings can meet a wide range of use. Balance charging­auto, balance charging-manual, normal charging, storage and discharging for Lithium batteries. charging-auto, charging-manual, discharging for NiCd/NiMH batteries. Charging and discharging for Pb batteries.
Various system settings: backlight, contrast, key sound, safty time, cut off temperature, cut off capacity.
Full protection system: protection of reversed polarity (input and output), higher/lower input voltage, battery temperature, over charge/discharge and time limited.
AC Input vo ltage range: DC Input vo ltage range: Charge cu rrent range: Dischar ge current range: Maximum c harge power: Maximum d ischarge power: Current d rain for balancing: Balance a ccuracy: LiPo/Li Io/LiFe battery cell count: NiCd/Ni MH battery cell count: Pb batter y cell count: Battery s etup memories: Temperature sensor: Weight: Dimensi on(LxWxD):
110-230V/50Hz
11.0-18.0V
0.5-10. 0A
0.5-5.0 A 100W @ 12V DC 10W 400mA <10mV 1-6 serie s 1-15 seri es 1-10 seri es (2-20V) 10 Yes 685g 135x145 x42mm
2x3 S in seri es Adapter
2x2 S in seri es Adapter
Temp era ture Se nsor( magne t)
C6P is ONLY suit able for charge re chargeable LiPo, LiFe, LiIo,NiMH and PB batteries. Do not attempt to charge dry cells. Charge other types of ba tteries may cause f ire or explosion.
Never leave the charge r unattended when it is workin g. If you leave, disconn ect the battery to prevent any unexpected dangerous or damage.
The prescript DC input voltage range from 11-18V. Never connect it to any other p ower supply which i s unsuitable.
Ensure progr am and s ettings match the battery pack, incorrect setting to charge/discharge a battery may damage the batter y, eve n would cause a fir e.
Protec t charger fro m dust, dirt a nd damp. Do no t attempt t o di s asse mble the c h arge r, c ont a ct th e aft e r sal es ce nter f or mainten ance if needed.
Never place the charger and batteries connect ed to it on any form of flammab le surface. Never operate the cha rger in the vicinity of inflamm able material or ga s.
Ensure that there is an unrestricted ai rflow to and from the charge r's cooling s lots.
Never charge or discharge any battery having eviden ce of leaking, expansi on/swelling, damage d oute r cover or case, color-cha nge or distort ion.
Take great care to maint ain correct battery polarity, and avoid shot-ci rcuit. R ead the batter y ma nufacturer's inst ructions and adhere to them str ictly.
BATTERIES a nd MA X CHARGE CURRENTWARNING and NOTES
5 6
Battery Type No. of Cells Rated Voltage(V) Max Ch arge Current(A)
1 3.7
10.0
2 7.4
10.0
3 11.1
9.0
4 14.8
6.8
5 18.5
5.4
6 22.2
4.5
1 3.3
10.0
2 6.6
10.0
3 9.9
10.0
4 13.2
7.6
5 16.5
6.1
6 19.8
5.1
1 3.6
10.0
2 7.2
10.0
3 10.8
9.3
4 14.4
6.9
5 18
5.6
6 21.6
4.6
1 1.2
10.0
2 2.4
10.0
3 3.6
10.0
4 4.8
10.0
5 6
10.0
6 7.2
10.0
7 8.4
10.0
8 9.6
10.0
9 10.8
9.3
10 12
8.3
11 13.2
7.6
12 14.4
6.9
13 15.6
6.4
14 16.8
6.0
15 18
5.6
NiCd
LiPo
LiFe
LiIo
NiMH
Same a s NiMH
7 8
1 2 10.0 2 4 10.0 3 6 10.0 4 8 10.0 5 10 10.0 6 12 8.3 7 14 7.1 8 16 6.3 9 18 5.6
10 20 5.0
Lipo
LiFe
LiIo
NiMH
NiCd
PB
Voltage Level: 1.2V/cell Max Charge Voltage: 1.6V/Cell Discharge Voltage Cut off Level: 0.85V/cell or Higher Voltage Level: 1.2V/cell Max Charge Voltage: 1.6V/Cell Discharge Voltage Cut off Level: 1.0V/cell or Higher Voltage Level: 2.0V/cell Max Charge Voltage:2.45V/Cell Discharge Voltage Cut off Level: 1.75V/cell or Higher
PB
Voltage Level: 3.7V/cell Max Charge Voltage: 4.2V/Cell Discharge Voltage Cut off Level: 3.0V/cell or Higher Voltage Level: 3.3V/cell Max Charge Voltage: 3.8V/Cell Discharge Voltage Cut off Level: 2.0V/cell or Higher Voltage Level: 3.6V/cell Max Charge Voltage: 4.1V/Cell Discharge Voltage Cut off Level: 3.0V/cell or Higher
SYSTEM SETTING
Li Po BA Lc har ge
Au to
a0010 v000
ma h0
0000 sy s me nu s ta rt
st an dby
Ba ck lig ht co nt ras t
ke y
sa ve
sy st em set ti ng
sa ft y te mp
ba ck
60 80
on
14 0
99
so un d
ti me
cu t
of f
ca p
cu t
of f
50 00
c
mi n
ma h
Ba ck lig ht
co nt ras t
ke y
sa ve
sy st em set ti ng
sa ft y te mp
ba ck
60
80
on
14 0
99
so un d
ti me
cu t
of f
ca p
cu t
of f
50 00
c
mi n
ma h
Ba ck lig ht co nt ras t ke y
sa ve
sy st em set ti ng
sa ft y te mp
ba ck
60 80 on
14 0
99
so un d
ti me
cu t
of f
ca p
cu t
of f
50 00
c
mi n
ma h
Ba ck lig ht
co nt ras t ke y
sa ve
sy st em set ti ng
sa ft y
te mp
ba ck
60
80 on
14 0
99
so un d
ti me
cu t
of f
ca p
cu t
of f
50 00
c
mi n
ma h
Ba ck lig ht co nt ras t ke y
sa ve
sy st em set ti ng
sa ft y
te mp
ba ck
60 80 on
14 0
99
so un d
ti me
cu t
of f
ca p
cu t
of f
50 00
c
mi n
ma h
LO AD 1
Ba ck lig ht
co nt ras t ke y
sy st em set ti ng
sa ft y te mp
60
80 on
14 0
99
so un d
ti me
cu t
of f
ca p
cu t
of f
50 00
c
mi n
ma h
sa ve ba ck
BAC KLIGH T:
Ran ge from 0 -100%
*Select : turn left/right *Enter/ Set: press
CON TRAST:
Ran ge from 0 -100%
KEY S OUND:
On/ Off opt ional
SAF TY TIME :
Cha rge/d ischa rge tim e lim it, range from 1 0-990 min utes. O ff=no l imit.
TEM PERATU RE CUTOFF:
Bat tery up per tem perat ure lim it. Ran ge from 2 0-99 °C. Off =no limit.
CAPA CITY CUTOFF:
Bat tery ca pacit y prote ction . Ran ge from 5 00-99 00 mAh. Off =no limit.
STANDBY Menu
SYSTEM SE TTING
Def ault me mory( the par amete r
set ting of l ast wor k of the ch arger )
Pre ss “START ” charg er will dir ectly w ork und er defa ult mem ory.
Pre ss “LOA D”, par amete r will cha nge to th e memor y you loa d, pre ss “START ” charg er will w ork und er the se tting o f the mem ory.
Ba ck lig ht 60
9 10
CH ARG E/DISCHARGE LIPO BATTERY
*Select : turn left/right *Enter/ Set: press
Li Po BA Lc har ge
Au to
a0010 v000
ma h0
0000 sy s me nu s ta rt
st an dby
BA TT
MO DE
TY PE
SCE LL
pa ra met er se tt ing
aCU RR ENT
mvtv c
ba ck
li po
ba lc har ge
au to
10 0 0
42 00
Li Po BA Lc har ge
6s
a691 v7024
ma h19 58
3812
cu rr ent st at us
ba tc6vc el l vdi ff
41 38 m v20 c5 41 35 m v17 c4 41 30 m v12 c3 41 25 m v7 c2 41 20 m v2 c1 41 18 mv0
BA TT
MO DE
TY PE
SCE LL
pa ra met er se tt ing
aCU RR ENT
mvtv c
ba ck
li po
st or age
au to
10 0 0
38 50
Li Po
st or age
6s
a692 v3819
ma h19 58
389
cu rr ent st at us
ba tc6vc el l vdi ff
32 38 mv20 c5 32 35 mv17 c4 32 30 mv12 c3 32 25 mv7 c2 32 20 mv2 c1 32 18 m v0
BA TT
MO DE
TY PE
SCE LL
pa ra met er se tt ing
aCU RR ENT
mvtv c
ba ck
li po
ch ar ge
au to
10 0 0
42 00
Li Po
ch ar ge
6s
a692 v3819
ma h19 58
389
cu rr ent st at us
BA TT
MO DE
TY PE
SCE LL
pa ra met er se tt ing
aCU RR ENT
mvtv c
ba ck
li po
di sc har ge
au to
10 0 0
36 00
Li Po di sc har ge
6s
a490 v3819
ma h19 58
389
cu rr ent st at us
ch ar ge
di sc har ge
LO AD 1
sa ve st ar t
1
sa ve st ar t
1
sa ve st ar t
1
sa ve st ar t
1
cu rr ent st at us
LIP O
BAL CHARG E: Bala nce charge STO RAGE: Stor age cha rge /disc harge (bala nce connecto r optional ) CHA RGE: No rmal charg e (bala nce connec tor not r equired) DIS CHARG E: Disc harge (bal ance co nnector op tiona l)
(ba lance c onnec tor req uired )
AUT O: Can be sele ct in bal ance charg e and storag e mode det ect the c ell cou nt of the b atter y.
1: Ch arge/ Disch arge 1 ce ll batt ery(N /A in balance cha rge mode) 2: Ch arge/ Disch arge 2 ce lls bat tery 3: Ch arge/ Disch arge 2 ce lls bat tery 4: Ch arge/ Disch arge 4 ce lls bat tery 5: Ch arge/ Disch arge 5 ce lls bat tery 6: Ch arge/ Disch arge 6 ce lls bat tery
, cha rger ca n autom atica lly
Imp ortan t note: I n non bal ance mo de, cha rger ca n not det ect the c orrec t cell co unt of th e bat tery wh ich has v oltag e inter section with t he other one . So the ce ll count you s et must b e exa ct the sa me as your batte ry, ot herwi se may cause d anger ous s ituat ion.
Set ting th e max cha rge/d ischa rge cur rent. R ange fr om 0.5- 10, cha nge uni t: 0.5
Termi nal Voltage Con trol. Rang e from 41 50-4250, c hange u nit: 10, def ault: 4 200 (St orage m ode ran ge from 3 800-3900 , defau lt: 3850)
Sav e the cur rent se tting t o 1st-9 th memo ry.
Con nect th e batte ry, pres s start, cha rger wi ll work unde r current se tting .
Bac k to “STAN DBY” menu.
Parameter setting Working stutus
c
28
c
28
c
28
Loading...
+ 9 hidden pages