Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the product
and proper installation; therefore, before attempting to install and operate your Casablanca fan, read this
owner’s manual completely and carefully. Retain this manual for future reference.
CAUTION: To avoid possible electrical shock, make certain that electricity is turned off at
the circuit breaker or fuse box before attempting any installation procedure.
BEFORE YOU START
• All wiring must be in accordance with the National Electric Code ANSI/NFPA 70-1993 and the appropriate local electrical
codes. The National Electric Code requires proper grounding as a precaution against electrical shock. A qualifi ed electrician should be consulted if you are unsure.
• This fan is designed to be installed on an existing electrical outlet box. The outlet box must be UL Listed for ceiling
fan installations. If it is not, a new box must be installed. Casablanca extension poles are available for sloped or high
ceiling installations.
• This ceiling fan requires a grounded electrical supply of 120 VAC, 60 Hz and a minimum 15-amp circuit. The maximum
current requirement for the fan with light fi xture is 3.8 amps. The fan uses about 1 amp or 100 watts. Maximum light
current is 0.83 amps (100 watts) of lighting.
• Where wire nuts are employed, be sure all bare wires are within the connectors. When installing the canopy hatch, make
sure all wires are within the canopy and that no wires are being pinched.
• The fan must be supplied with 3 independent 120V AC supply wires to provide power for the fan, the light, and neutral.
For best performance and for your warranty to be valid,
use only genuine Casablanca blades, light fi xtures, and accessories.
• The blades in each pack are matched for
equal weight to assure smooth fan operation.
If more than one fan is being installed, be
careful not to mix blades from different
cartons.
• Inspect the contents of your carton for
possible shipping or handling damage. If
parts are missing or damaged, call 1-888227-2178.
• It is always a good idea to have an assistant
to help with the installation.
• When cleaning, painting, or working near
your fan, be very careful of the fan and
blades. Always turn the power OFF to the
ceiling fan before servicing it, working on
it, or replacing lightbulbs.
• Never insert anything into the path of the
fan blades while the fan is in operation.
• Never install a fan over a pool or spa.
• Never operate a fan that has been damaged in
any way. Contact Casablanca Fan Company by
calling 1-888-227-2178, or contact your local
Authorized Casablanca Dealer for assistance
in obtaining service.
P/N 6543010 REV. F P/D AT0208
SAFE USE
FUSE BOX
(REMOVE FUSE FOR THE
CIRCUIT YOU WILL BE
WORKING ON)
CIRCUIT BREAKER
(TRIP BREAKER FOR THE
CIRCUIT YOU WILL BE
WORKING ON)
18"
FROM BOTTOM
EDGE OF BLADE
TO FLOOR
84"
DIMENTIONS INDICATED ARE THE
MINIMUM ALLOWABLE FOR PROPER
INSTALLATION
1
MOUNTING RECOMMENDATIONS
Before mounting your Casablanca fan, read the following helpful recommendations. The location of the fan, air circulation,
and fan size are all important factors to consider before installation.
Location
Ceiling fans have practical uses in almost every room in your home. We suggest you follow these mounting recommendations as you decide where to install your Casablanca fan.
• For safety reasons, the fan blades must be a minimum of 7′ above the fl oor.
• Do not locate the fan in a doorway or above a swinging door.
• In any installation, the tips of the blades must be at least 18” from the wall in order to
provide suffi cient clearance for the blades.
• In bedrooms, fans work best when mounted above the foot of the bed.
• Over pool tables, be sure to provide plenty of clearance to avoid damage from
pool cues.
• In kitchens be sure to allow for open cupboard doors to clear the fan blades.
• Do not install a fan close to, or over, a pool or spa. High humidity combined
with corrosive gases will destroy the fi nish and warp the blades.
Fan Size
Variable fan speed capability permits the use of a full-size 52" fan even in
smaller rooms. For very large rooms, two fans may be needed.
SLOPED CEILING INSTALLATIONS
CAUTION: Installation of this fan requires
a minimum 10-foot ceiling.
EXTENSION
POLE
MAXIMUM
HANG-TRU®
ANGLE 32º
32°
Suggested Extension Pole Lengths
Ceiling Height
10′
10′ 6”
11′
11′ 6”
12′
13′
14′
Pole Length
standard
standard
18”
18”
24”
36”
48”
When to Use Extension Poles
For best performance and best appearance,
an extension pole should be used with
your Casablanca fan when installing on
high (cathedral) ceilings or sloped ceilings. Casablanca offers standard poles in
increments of 6” up to 5”. Custom poles
are available in lengths up to 10’. See your
Authorized Casablanca Dealer for details.
Note: Fan may wobble or vibrate if
pole length is not long enough and
inside blade is too close to downslope
or side wall. Extending pole length
usually will solve problem.
Calculation of 32°
Use the tear-off Ceiling Angle Template card inserted in the
back of this manual, it provides you with a simple “go” or
“no-go” for installing your fan on a sloped ceiling.
BLADES MUST BE
A MINIMUM OF 7′
ABOVE THE FLOOR
7′ MINIMUM
EXAMPLE 1
This slope is less than 32º.
It is OK to install your fan.
EXAMPLE 2
This slope is 32
slope that will allow the fan to hang
straight down. It is OK to install your
fan.
EXAMPLE 3
This slope is more than 32
Your fan will not hang straight down, an
adaptor is necessary. Contact your local
Authorized Casablanca Dealer in regards to
purchasing a “Sloped Ceiling Adapter.”
º. This is the maximum
º.
2
™
VERRAZANO
PREPARATION INSTRUCTIONS
Unpacking: Before assembling and installing your ceiling fan, remove all parts from the shipping cartons and check them
against the parts listed here. Before discarding packaging material, be certain that all parts have been removed.
GETTING STARTED
Carton Contents
The fan carton contains the fan body, warranty card, owner’s
manual, and all the parts necessary to assemble and install
your Casablanca ceiling fan. These parts are shown at the
start of each installation section. Before you start, go through
this Owner’s Manual and confi rm that you have all the parts
shown in each section.
PERMA•LOCK™ HARDWARE
ALLEN SET SCREW
¼-20 x ¼”
(PRE-INSTALLED)
ALLEN WRENCH
FAN PREPARATION
IMPORTANT SAFETY INFORMATION!
BEFORE STARTING THE INSTALLATION OF YOUR CEILING FAN, IN-
STALL THE THREADED DOWNROD INTO THE MOTOR COUPLING AND
LOCK THE ASSEMBLY
Prepare for fan installation as follows:
Step A. Route the wires from the motor through the
Perma•Lock™ downrod and ball assembly, keeping the wires
to one side of the cross pin.
NOTE: The downrod has a tapered thread
that is designed to lock completely when
correctly installed.
Step B. Using the provided Allen wrench, loosen the Allen
set screw. Thread the downrod into the motor coupling until
it stops turning, this will take at least four and a half full
turns.
Step C. Securely tighten the Allen set screw with the provided
Allen wrench to ensure safe operation of your fan.
Be sure to use only genuine Casablanca blades. The blade
shrink wrap holds 4 blades of matched weight. If more than
one fan is being installed, be sure not to mix blade sets.
CAUTION: When removing the shrink wrap,
be careful not to scratch the blades.
DOWNROD & BALL
ASSEMBLY
GROUND
MOTOR
WIRES
TAPERED
THREAD
ALLEN SET
SCREW
WIRE
DOWNROD
&
BALL
ASSEMBLY
MOTOR
COUPLING
REVERSE
SWITCH
CAUTION: Failure to fully lock in the downrod before securely tightening the locking
bolt may cause the fan to fall during normal
operation!
GETTING STARTED
Installing a New Ceiling Fixture Outlet Box
If you do not have an existing fi xture located where you wish
to place your Casablanca fan, an approved ceiling fi xture
outlet box must be installed and wired.
Warning: To reduce the risk of fi re, electrical shock,
or personal injury, mount to outlet box marked acceptable for ceiling fan support using the mounting
hardware provided with the outlet box.
Using Existing Ceiling Fixture Outlet Box
After turning the power OFF at its source (either circuit
breaker or fuse box), lower the old fi xture and disconnect
the wiring. Check the ceiling fi xture outlet box to be sure
that it is marked “Approved for ceiling fan mounting.” If it is
not, a new box must be installed.
NOTE: The fan weight is 37.5 pounds.
3
CROSSBAR MOUNT-
ING BRACKET
SUPPORT INSTALLATION PARTS
CEILING HARDWARE
WIRE NUT (4)
1” x 8-32 ROUNDED
HEAD SCREW (2)
ADDITIONAL HARDWARE
1
2
/4” x 8-32 ROUNDED
HEAD SCREW (2)
FLAT WASHER (2)
LAG SCREW
¼” #7 X 5” (1)
CROSSBAR MOUNTING BRACKET INSTALLATION
Note: After removing the old fi xture, check the outlet box
to ensure that it is supported by a joist or beam across its
upper surface. If not, a 2” x 4” stud must be installed.
Step 1. Remove the knockout plug in the center of the outlet box or drill a
Then drill a
of 3”.
Step 2. Route the outlet box wires through the keyhole slot of
the crossbar mounting bracket as shown. Attach the crossbar
mounting bracket to outlet box with screws provided, assuring
that the outlet box wires are not pinched by the washer.
CAUTION: To reduce the risk of personal injury,
use only the mounting hardware provided with
the approved outlet box to install the crossbar
mounting bracket.
1
/2” hole for the lag screw to pass through.
1
/4” guide hole into the joist or beam to a depth
JOIST
CEILING FAN
APPROVED
WIRING BOX
CROSSBAR
MOUNTING
BRACKET
LARGE
FLAT WASHER
¼” (1)
CEILING
WIRING
RIDGE
SIDE
DOWN
4
WARNING!
SUPPORT DIRECTLY TO
BUILDING STRUCTURE ONLY.
FLAT
WASHER
APPROVED
OUTLET BOX
HARDWARE
GREEN
GROUND
WIRE
LAG SCREW INSTALLATION
Step 3. With the large washer attached, pass the lag screw
through the center hole of the crosbar mounting bracket
and screw into guide hole. Tighten until outlet box is fi rmly
mounted to beam. This box must be secured fi rmly to the
ceiling. We recommend that the ceiling fi xture outlet box
be of suffi cient capacity enabling it to support the weight
of fan and light fi xture under any conditions.
™
VERRAZANO
LAG
SCREW
LARGE
WASHER
CANOPY HARDWARE
CANOPY
HATCH
CANOPY
CANOPY INSTALLATION
Step 4. Attach the canopy to the crossbar mounting bracket with three of
the 8-32 x 2
Casablanca fan. Hand-tighten until snug against the ceiling.
1
/
” long canopy screws and lock washers provided with your
2
Note: On sloped ceilings, align the
canopy opening toward the top or
peak of the room.
CANOPY SCREW (4)
CANOPY LOCK WASHER (4)
CANOPY
LOCK
WASHER
FEED OUTLET BOX
WIRES THROUGH
CANOPY OPENING
CANOPY