Casablanca Fan Company 46U26D, 46U73D, 46U73M, 46U4M, 46U4D User Manual

CAPISTRANO
OWNERS MANUAL
Casablanca
13

CONTENTS

INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
MOUNTING RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
PREPARATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
FAN INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CONTROL FEATURES:
3-SPEED OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
READ AND SAVE THESE INSTRUCTIONS

SAFETY FIRST

Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the product and proper installation; therefore, before attempting to install and operate your Casablanca fan, read this owner’s manual completely and carefully. Retain this manual for future reference.
CAUTION: T o av oid possible electrical shock, make certain that electricity is turned o ff at the circuit breaker or fuse box before attempting any installation procedure.
BEFORE YOU START
All wiring must be in accord ance with th e Nati onal Electri c Code ANSI/NFPA 70-1993 and th e appropriate local electri cal
codes. The N ati on al Electri c Cod e requir es proper groundin g as a precauti on again st electri cal sh ock. A qu alifi ed electri­cian should be consulted if you are unsure.
• This fan is design ed to be in stalled on an e xisting electri cal outlet bo x. Th e outlet box m ust be UL Listed f or ceilin g f an installations , if it is not, a n ew box must be in stalled. Casablan ca extensi on poles are available f or sloped or high ceilin g installations.
This ceiling fan requires a grounded electrical supply of 120 VAC, 60 Hz and a minimum 15 amp circuit. The maximum current requirement for the fan with light fixture is 3.8 amps. The fan uses about 1 amp or 100 watts. Maximum light current is 2.8 amps or 340 watts of lighting.
Where wire n uts are employed , be sur e all bare wir es are within th e conn ectors. Wh en in stalling th e canopy hatch, m ak e sure all wires are within the canopy and that no wires are being pinched.
For best performance and for your warranty to be valid,
use only genuine Casablanca blades, light fixtures, and accessories.
The blades in each pack are m atched for equal weight to assure smooth fan operation. If more than one fan is being installed, be careful not to mix blades from different cartons.
Inspect the contents of your carton for possible shipping or handling damage and report any such damage directly to your authorized Casablanca dealer.
It is always a good id ea to have an assistant to help with the installation.
When cleaning, painting, or working near your fan, be very careful of th e fan and blades. Always turn the power OFF to the ceiling f an before servicin g it, working on it, or replacing light bulbs.
Never insert anything into the path of the fan blades while the fan is in operation.
• Never install a fan over a pool or spa.
Never operate a fan that has been damaged in any way . Contact Casablanca Fan Compan y by calling 1-800-759-FANS (3267), or contact your local authorized Casablanca dealer for assistance in obtaining service.
P/N 4643010 REV.A P/D MAR98PDG
SAFE USE
FUSE BOX
(REMOVE FUSE FOR THE
CIRCUIT YOU WILL BE
WORKING ON)
CIRCUIT BREAKER
(TRIP BREAKER FOR THE
WORKING ON)
18
70
84
1

MOUNTING RECOMMENDATIONS

Before moun ting your Casablan ca f an, read th e following helpful recommendation s . The locati on o f the f an, air cir culation, and fan size are all important factors to consider before installation.
Location
Ceiling fans have pr actical uses in alm ost every r oom in your h om e . W e sugg est you f ollow th ese m ount­ing recommendations as you decide where to install your Casablanca fan.
• For safety reasons, the fan blades must be a minimum of 7 above the floor.
• Do not locate the fan in a doorway or above a swinging door.
• In any installation, the tips of the blades must be at least 18 from the wall in order to provide sufficient clearance for the blades.
• In bedrooms, fans work best when mounted above the foot of the bed.
• Over pool tables, be sure to provide plenty of clearance to avoid damage from pool cues.
• In low ceiling locations, our optional low ceiling adaptor (LCS) - available at extra cost can be used to gain 3
1
/2 (not applicable to Stealth series).
• In kitchens be sure to allow for open cupboard doors to clear the fan blades.
• Do not install a fan close to, or over, a pool or spa. High humidity combined with corrosive gases will destroy the finish and warp the blades.
Fan Size
Variable f an speed capability permits the use o f a full-size 52 f an even in smaller rooms. For very large rooms, two fans may be needed.
SLOPED CEILING INSTALLATIONS
Suggested Extension Pole Lengths
Ceiling Height
8
8 6
9
9 6
10 11 12 13 14
Pole Length
Standard Standard
6 12 12 18 24 36 48
EXTENSION
POLE
MAXIMUM
HANG-TRU®
ANGLE 32º
BLADES MUST BE A
MINIMUM OF 7
ABOVE THE FLOOR
32°
When to Use Extension Poles
For best performance and best appear ance, an extension pole should be used with your Casablanca fan when installing on high (cathedral) ceilings or sloped ceil­ings. Casablanca offers standard poles in increments of 6 up to 5. Custom poles are available in lengths up to 10. See your Authorized Casablanca Dealer f or details.
Note: Fan may wobble or vibrate if pole length is not long enough and inside blade is too close to downslope or side wall. Extending pole length will usually solve problem.
Calculation of 32°
Use the tear-off Ceiling Angle Template card inserted in the back of this manual, it provides you with a simple ‘go’ or ‘no-go’ for installing your fan on a sloped ceiling.
2
EXAMPLE 1
This slope is less than 32°. It is OK to install your fan.
EXAMPLE 2
This slope is 32°. This is the maximum slope that will allow the fan to hang straight down. It is OK to install your fan.
EXAMPLE 3
This slope is more than 32°. Your fan will not hang straight down, an adaptor is necessary. Contact you local Authorized Casablanca Dealer in regards to purchasing a 'Slope Ceiling Adaptor'.
7 MINIMUM
EXAMPLE 1
This slope is less than 32˚. It is OK to install your fan.
EXAMPLE 2
This slope is 32˚. This is the maximum slope that will allow the fan to hang straight down. It is OK to install your fan.
EXAMPLE 3
This slope is more than 32˚. Your fan will n ot han g str ai ght d own, an adaptor is necessary. Contact your local Authorized Casablanca Dealer in regards to purchasing a “Slope Ceiling Adaptor.”
CAPISTRANO
Casablanca
PREPARATION INSTRUCTIONS
Unpacking: Before assembling and installing your ceiling fan, remove all parts from the shipping cartons and check them against the parts listed here. Before discarding packaging material, be certain that all parts have been removed.

PERMA•LOCK™ HARDWARE

LOCKING BOLT
(MOTOR COUPLING)

FAN PREPARATION

IMPORTANT SAFETY INFORMATION!
BEFORE STARTING THE INSTALLATION OF YOUR CEILING FAN,
INSTALL THE THREADED DOWNROD INTO THE MOTOR COUPLING AND
LOCK THE ASSEMBLY
Prepare for fan installation as follows: Step A. Route the wires from the motor through the
Perma•Lock™ downrod and ball assembly, keeping the wires to one side of the cross pin.
NOTE: The downrod has a tapered thread that is designed to lock completely when correctly installed.
Step B. Thread the downrod into the motor coupling until it stops turning, this will take at least four an d a half full turns. Step C. Securely tighten the locking bolt to ensure safe op­eration of your fan.
CAUTION: Failur e to fully lock in the down­rod before securely tightening the locking bolt may cause the fan to fall during nor­mal operation!
LOCKING
BOLT
GROUND
WIRE
TAPERED
THREAD
DOWNROD & BALL
ASSEMBLY
MOTOR
WIRES
DOWNROD
&
BALL
ASSEMBLY
MOTOR
COUPLING

CEILING HARDWARE

CROSSBAR
MOUNTING
BRACKET
WIRE NUT (4)

GETTING STARTED

Installing a New Ceiling Fixture Outlet Box
If you do not have an existin g fixture located where you wish to place your Casablanca fan, an approved ceiling fixture outlet box must be installed and wired.
Warning: T o reduce the risk of fire , electrical shock, or personal injury, mount to outlet box marked acceptable for ceiling fan support using the mount­ing hardware provided with the outlet box.
ADDITIONAL HARDWARE
1
2
/4x 8-32 ROUNDED
HEAD SCREW (2)
1 x 8-32 ROUNDED HEAD SCREW (2)
Using Existing Ceiling Fixture Outlet Box
After turning the power OFF at its source (eith er circuit breaker or fuse box), lower the old fixture an d disconnect the wiring. Check the ceiling fixture outlet box to be sure that it is marked ‘Approved for ceiling f an mounting’. If it is not, a new box must be installed.
FLAT WASHER (2)
3
CAPISTRANO
Casablanca
CROSSBAR MOUNTING BRACKET INSTALLATION
Proceed with installation as follow s: Step 1. Route the wires from th e ceilin g outlet bo x thr ough
the crossbar mountin g bracket center h ole. Attach th e bracket, with ground wire an d ridges d own, to the ceiling fixtur e out­let box with the moun ting hard ware includ ed with the outlet box. Tighten the scr ews firmly by hand only, being careful not to bend the bracket by over tightening.
CEILING FAN
APPROVED
OUTLET BOX
CEILING WIRING
RIDGE
SIDE
DOWN
CAUTION: To reduce the risk of personal injury, use only the mounting hardware pr ovided with the approved outlet bo x to install the crossbar mounting bracket.
CANOPY
HATCH
CROSSBAR
MOUNTING
BRACKET
FLAT
WASHER

CANOPY HARDWARE

CANOPY LOCK WASHER (4)
CANOPY

CANOPY INSTALLATION

GREEN
GROUND
WIRE
OUTLET BOX
MOUNTING
HARDWARE
CANOPY SCREW (4)
Step 2. Attach the canopy to th e crossbar moun t-
ing bracket with three of the 8-32 x 2
1
/4″ long
canopy screws and canopy lock washers. Tighten the screw firmly by hand only.
Note: On sloped ceilings, align the canopy opening towards the top or room peak.
4

CROSSBAR MOUNTING

BRACKET INSTALLED
CANOPY
CANOPY LOCK
WASHERS
CANOPY SCREWS
Loading...
+ 9 hidden pages