Casablanca Fan Compagny METROPOLITAN User Manual

METROPOLITAN
OWNERS MANUAL

CONTENTS

INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
MOUNTING RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FAN INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CONTROL FEATURES:
INTELI•TOUCH OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
TROUBLESHOOTING INTELI•TOUCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
COMFORT•TOUCH OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
TROUBLESHOOTING COMFORT•TOUCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
READ AND SAVE THESE INSTRUCTIONS

SAFETY FIRST

Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the product and proper installation; therefore, before attempting to install and operate y our Casablanca fan, read this owner’s manual completely and carefully. Retain this manual for future reference.
CAUTION: T o av oid possible electrical shock, make certain that electricity is turned o ff at the circuit breaker or fuse box before attempting any installation procedure.
BEFORE YOU START
All wiring must be in accord ance with th e Nati onal Electri c Code ANSI/NFPA 70-1993 and the appropri ate local electrical
codes. The N ati on al Electri c Cod e requir es proper grounding as a precauti on against electri cal sh ock. A qu alifi ed electri­cian should be consulted if you are unsure.
• This fan is design ed to be in stalled on an e xisting electri cal outlet bo x. Th e outlet box m ust be UL Listed f or ceilin g f an installations , if it is not, a n ew box must be in stalled. Casablan ca extensi on poles are available f or sloped or high ceilin g installations.
This ceiling fan requires a grounded electrical supply of 120 VAC, 60 Hz and a minimum 15 amp circuit. The maximum current requirement for the fan with light fixture is 3.8 amps. The fan uses about 1 amp or 100 watts. Maximum light current is 2.8 amps or 340 watts of lighting.
Where wire n uts are employed , be sur e all bare wir es are within th e conn ectors. Wh en in stalling th e canopy hatch, m ak e sure all wires are within the canopy and that no wires are being pinched.
For best performance and for your warranty to be valid,
use only genuine Casablanca blades, light fixtures, and accessories.
The blades in each pack are m atched for equal weight to assure smooth fan operation. If more than one fan is being installed, be careful not to mix blades from different cartons.
Inspect the contents of your carton for possible shipping or handling damage and report any such damage directly to your authorized Casablanca dealer.
It is always a good id ea to have an assistant to help with the installation.
When cleaning, painting, or working near your fan, be very careful of th e fan and blades. Always turn the power OFF to the ceiling f an before servicin g it, working on it, or replacing light bulbs.
Never insert anything into the path of the fan blades while the fan is in operation.
• Never install a fan over a pool or spa.
Never operate a fan that has been damaged in any way . Contact Casablanca Fan Compan y by calling toll free 1-888-227-2178, or contact your local authorized Casablanca dealer for assistance in obtaining service.
P/N 4843010 REV.B P/D MAR00PDG

SAFE USE

FUSE BOX
CIRCUIT YOU WILL BE
WORKING ON)
CIRCUIT BREAKER
(TRIP BREAKER FOR THE
CIRCUIT YOU WILL BE
WORKING ON)
18
70
84
CAUTION: MOUNT WITH THE LOWEST MOVING PARTS AT LEAST 2.5 METRES ABOVE FLOOR OR GRADE LEVEL. ATTENTION: INSTALLER DE SORTE QUELES PIÈCES INFÉRIEURES SOIENT À AU MOINS 2.5 MÈTRES AU-DESSUS DU PLANCHER OU DU SOL.
1

MOUNTING RECOMMENDATIONS

Before moun ting your Casablan ca f an, read th e following helpful recommen dati on s. Th e locati on of th e f an, air circulati on, and fan size are all important factors to consider before installation.
Location
Ceiling fans have pr actical uses in alm ost every r oom in your h om e . W e sugg est you f ollow th ese m ount­ing recommendations as you decide where to install your Casablanca fan.
• For safety reasons, the fan blades must be a minimum of 7 above the floor.
• Do not locate the fan in a doorway or above a swinging door.
• In any installation, the tips of the blades must be at least 18 from the wall in order to provide sufficient clearance for the blades.
• In bedrooms, fans work best when mounted above the foot of the bed.
• Over pool tables, be sure to provide plenty of clearance to avoid damage from pool cues.
• In low ceiling locations, our optional Low Ceiling Adaptor (LCA)—available at extra cost—can be used to gain 3
1
/2.
• In kitchens be sure to allow for open cupboard doors to clear the fan blades.
• Do not install a fan close to, or over, a pool or spa. High humidity combined with corrosive gases will destroy the finish and warp the blades.
Fan Size
Variable f an speed capability permits the use o f a full-size 52 f an even in smaller rooms. For very large rooms, two fans may be needed.

SLOPED CEILING INSTALLATIONS

Suggested Extension Pole Lengths
Ceiling Height
8
8 6
9
9 6
10 11 12 13 14
Pole Length
Standard Standard
6 12 12 18 24 36 48
EXTENSION
POLE
MAXIMUM
HANG-TRU®
ANGLE 32º
BLADES MUST BE A
MINIMUM OF 7
ABOVE THE FLOOR
32°
When to Use Extension Poles
For best performance and best appear ance, an extension pole should be used with your Casablanca fan when installing on high (cathedral) ceilings or sloped ceil­ings. Casablanca offers standard poles in increments of 6 up to 5. Custom poles are available in lengths up to 10. See your Authorized Casablanca Dealer f or details.
Note: Fan may wobble or vibrate if pole length is not long enough and inside blade is too close to downslope or side wall. Extending pole length will usually solve problem.
Calculation of 32°
Use the tear-off Ceiling Angle Template card inserted in the back of this manual, it provides you with a simple ‘go’ or ‘no-go’ for installing your fan on a sloped ceiling.
2
7 MINIMUM
EXAMPLE 1
This slope is less than 32˚. It is OK to install your fan.
EXAMPLE 2
This slope is 32˚. This is the maximum slope that will allow the fan to hang straight down. It is OK to install your fan.
EXAMPLE 3
This slope is more than 32˚. Your fan will n ot han g str ai ght d own, an adaptor is necessary. Contact your local Authorized Casablanca Dealer in regards to purchasing a “Slope Ceiling Adaptor.”
METROPOLITAN

INSTALLATION INSTRUCTIONS

Unpacking: Before assembling and installing your ceiling fan, remove all parts from the shipping cartons and check them against the parts listed here. Before discarding packaging material, be certain that all parts have been removed.
PERMA•LOCK™ HARDWARE
ALLEN SET SCREW
1
⁄4-20 x 1⁄4"
(PRE-INSTALLED)
3mm
ALLEN WRENCH

FAN PREPARATION

IMPORTANT SAFETY INFORMATION!
BEFORE STARTING THE INSTALLATION OF YOUR CEILING FAN, INSTALL THE
THREADED DOWNROD INTO THE MOTOR COUPLING AND LOCK THE ASSEMBLY
Prepare for fan installation as follows: Step A. Route the wires from the motor through the
Perma•Lock™ downrod and ball assembly.
Tip: The downrod has a tapered thread that is designed to lock completely when correctly installed.
Step B. Using th e provid ed allen wrench, loosen the set scr ew several turns to allow installation of the downrod. Thread the downrod into the motor coupling until it stops turning, this will take at least four and a half full turns.
Step C. Securely tighten th e set screw with the provi ded allen wrench to ensure safe operation of your fan.
CAUTION: Failure to fully lock in the do wn­rod before secur ely tightening the allen set screw may cause the fan to separate from the downrod during normal operation!
DOWNROD & BALL
ASSEMBLY
MOTOR
WIRES
GROUND
WIRE
DOWNROD
& BALL
ASSEMBLY
TAPERED
THREAD
ALLEN
SET SCREW
MOTOR
COUPLING

CEILING HARDWARE

CROSSBAR
MOUNTING
BRACKET
WIRE NUT (4)

GETTING STARTED - CONTINUED

Installing a New Ceiling Fixture Outlet Box
If you do not have an existin g fixture located where you wish to place your Casablanca fan, an approved ceiling fixture outlet box must be installed and wired.
Warning: T o reduce the risk of fire , electrical shock, or personal injury, mount to outlet box marked acceptable for ceiling fan support.
ADDITIONAL HARDWARE
CROSSBAR MOUNTING BRACKET SCREW 2
CROSSBAR MOUNTING BRACKET SCREW 1″(2)
Using Existing Ceiling Fixture Outlet Box
After turning the power OFF at its source (eith er circuit breaker or fuse box), lower the old fixture an d disconnect the wiring. Check the ceiling fixture outlet box to be sure that it is marked ‘Approved for ceiling f an mounting’. If it is not, a new box must be installed.
1
/4(2)
FLAT WASHER (2)
3
METROPOLITAN

CROSSBAR MOUNTING BRACKET INSTALLATION

Proceed with installation as follow s: Step 1. Route the wires from th e ceilin g outlet bo x thr ough
the crossbar mountin g bracket center h ole. Attach th e bracket, with ground wire an d ridg es down, to th e ‘ Appr oved For Ceil­ing Fan Installation’ ceilin g fixture outlet box with the outlet box mounting hardware. Tighten the screws firmly, being careful not to bend the bracket by over tightening.
CAUTION: To reduce the risk of personal injury, use only the mounting hardware pr ovided with the approved outlet box to install the crossbar mounting bracket.
CEILING FAN
APPROVED
WIRING BOX
CROSSBAR
MOUNTING
BRACKET
CEILING WIRING
FLAT
WASHER
RIDGE
SIDE
DOWN
GREEN
GROUND
WIRE
APPROVED
OUTLET BOX
HARDWARE

CANOPY HARDWARE

CANOPY
HATCH
CANOPY

CANOPY INSTALLATION

Step 2. Attach the canopy to th e crossbar moun t-
ing bracket with three of the 8-32 x 2 canopy screws and canopy lock washers. Hand tighten until snug against the ceiling.
Note: On sloped ceilings, align the canopy opening towards the top or room peak.
1
/4″ long
CANOPY SCREW (4)
CANOPY LOCK WASHER (4)
CROSSBAR MOUNTING
BRACKET INSTALLED
CANOPY
CANOPY LOCK
WASHERS
4
CANOPY SCREWS
Step 3. To hang the fan body in the
canopy , h old the fan bod y firmly and in­sert the nylon ball into the canopy opening. Check that no wires were pinched. Rotate the fan body until the slot in the nylon ball fits into the pin opposite the canopy opening.
METROPOLITAN

HANGING THE FAN

BALL

CANOPY ELECTRICAL CONNECTIONS

Step 4. Attach the fan wir es to the ceiling fixtur e outlet box
wiring by twisting the bare ends of the wires together and then securing with a wire nut. Test that the connection is secure by pulling on the wire nut. Connect in this order:
Electrical Connections
• GREEN leads from mountin g plate and fan to GROUND conductor of power source. Secure with wire nut.
• WHITE wire from fan to white NEUTRAL wire in ceil­ing fixture outlet box. Secure with wire nut.
• BLACK power wire from fan to BLACK power wire in ceiling outlet box. Secure with wire nut.

CANOPY HATCH INSTALLATION

Step 5. Tuck the wires into the canopy
with the wire nuts pointed upwards, so that the WHITE and BLACK wires are on opposite sides of th e canopy and all wires are clear of the canopy opening.
SLOT
2 BLACK WIRES
2 WHITE WIRES
WIRE NUT
CANOPY
HATCH
PIN
3 GREEN WIRES
Step 6. Install canopy hatch with the last
canopy screw and lock wash er . To do this , tilt the fan body away from the hatch opening. Tighten the screws firmly by hand only,
Step 7. Straighten the fan, then check to ensure that ther e is no m ovemen t be­tween the canopy and ceilin g or Hang-Tru ball and top support shaft.
LOCK
WASHER
CANOPY
SCREW
Note: Write down the Serial Number and the model number for future reference.
TILT THE
FAN TO
INSTALL
LAST
CANOPY
SCREW
5
Loading...
+ 12 hidden pages