INTRODUCTION 4 CAUTIONS 4 FEATURES & MAIN FUNCTIONS 4 SPECIFICATIONS 5 PART NAME AND FUNCTION 5 SYSTEM MODE 7 GENERAL FUNCTION & DESCRIPTION 13 CONVERSION MODE 15 RS-232C COMMUNICATION 15 INSTALLING 18 USING & KEEPING 19 BATTERY 19 TEST FUNCTION 21 CALIBRATION MODE 23 SEALING & OPTIONAL DRAWING 26 ERROR MESSAGE DESCRIPTION
AND MANAGEMENT 27
INTRODUCTION
We greatly appreciate for you to purchase BI-SERIES of CAS. This goods has the excellent performance and splendid properties through strict test under severe quality management. It is recommended to read this manual in full before using BI-SERIES for good function application.
4
CAUTIONS!
Do not press the key strongly. Do not use the inflammables at cleaning. Do not install in the place with sudden temperature change. Do not install in the place with high voltage and terrible electrical noises. Do not use in the place exposed directly to the sun and including much dust. Do not use in the place with excessive electrical noises and shaking. Charge a battery in full to use after negligence for a long time. Install the platform on a flat place.
FEATURES
Simple outdoor using in use of battery Using general (Mn, Alkaline) battery or rechargeable battery Easy operation and various functions SPAC Single pass automatic span calibration Waterproof(IP65) High precise resolution Liquid crystal display of 5 place weight (LCD) Using long-time battery Various options (Wall mount, Fixed bracket, RS232)
Main functions
Weight averaging function(Hold function) COUNT function (Unit weight setting, unit weight setting by sample) Low/High weight comparing Auto power OFF
TM
5
SPECIFICATION
BI-SERIES
ITEM
MODEL
LOADCELL PERMISSION VOLTAGE
TEMPERATURE RANGE
ZERO CALIBRATION RANGE
REZERO RANGE
INITIAL ZERO RANGE
INPUT SENSITIVITY
A/ D INTERNAL RESOLUTION
A/ D EXTERNAL RESOLUTION
MAX. TARE RANGE
WEIGHT DISPLAY TYPE
CHARACTER DISPLAY
CONSUMPTION
5V DC
10 C 40 C
0.05mV 5mV
2% of Max. Capacity
20% of Max. Capacity
1 V/D more
1/ 100,000 (MAX.)
1/ 10,000 (MAX.)
Maximum capacity
5 place LCD(Char. size 23.5mm)
1.Stable ( ) 2. High, Normal, Low (HI, OK, LO)
3.Battery discharge (BAT) 4. quantity unit (PCS)
5.Weight unit (kg, lb)
Approx. 0.15W
Part name and function
Part name
Lcd Display
Loadcell
Contact output, RS232C
key
Top cover
Bottom Cover
Adapter connector
OPTIONAL
BI-100D BI-100R BI-100DB BI-100RB
DC1.5V(6EA)
Mn battery
DC1.2V(6EA)
Recharging
battery
DC12Vadapter
DC1.5V(6EA)
Mn battery
DC1.2V(6EA)
Recharging
battery
DC12Vadapter
BACK LIGHT
ZERO lamp : ON when the current weight is °∞0°±. TARE lamp : ON when the TARE weight is saved. GROSS weight lamp : ON at displaying the total weight. NET weight lamp : ON at displaying the pure weight. Hold lamp : ON at weighing the moving object. BAT lamp : In case of rechargeable battery, display the battery
recharging time. In case of general Mn/Alkaline battery, display the battery replacing time.
CHARGE lamp : OFF when the charging is completed at charging
in use of adapter.
POWER lamp : ON at connecting DC 12V adapter.
lamp : ON when the current weight exceeds normal weight. lamp : ON when the current weight is normal.
lamp : ON when the current weight is 80-90% of normal
weight
lamp: ON when the current weight is 50-80% of normal
weight
lamp: ON when the current weight is below 50% of normal
weight.
6
Display part
kg
lb
pc
s
HI
OK
LO
B A T
KEY PART
KEY FUNCTIONS
KEY:Use to power ON/OFF.
KEY:Use in case of rezero(within 2% of max. capacity)
or to enter the system mode by pressing for 2 sec.
KEY:Use at weighing in use of TARE.
KEY:Use to turn ON/OFF BACK LIGHT.(Option)
ZERO GROSS NET TARE HOLD
POWER
CHARGE
kg
lb
pcs
HI
OK
LO
HI
B A T
lb
pcs
HI
OK
kg
lb
pcs
HI
OK
LO
HI
OK
B A T
kg
lb
pcs
HI
OK
LO
HI
OK
B A T
kg
lb
pcs
HI
OK
LO
HI
OK
LO
B A T
ON/OFF
ZERO MODE
TARE
Key functions in Simple weighing mode
& in Low/High comparing mode.
7
KEY: Use to display NET weight or GROSS weight.
KEY: Use to weigh the moving object.
(Manual, Automatic)
Key functions in COUNT mode
KEY: Use to display the unit weight.(for approx. 5 sec.)
KEY: Use to display the current weight.
(for approx. 5 sec.)
SYSTEM MODE
Simple weighing mode : Display the weight after weighing. High/Low comparing mode : Determine that the weight is high,
normal or low value and perform the display.
Count mode : Display the quantity by setting the unit or sample
weight.
Quantity comparing mode : Perform the display after discrimination
by setting High/Low quantity.
MODE CONVERSION
Press key for 2 sec. to display the following message.
kg
LO
Execute depending on the below mode conversion and setting method.
DIGIT INPUT METHOD
Input the digit in use of the below keys.
KEY: Use to set the inputted value to 0 .
KEY: Use to increase the first place of value by one.
NET
GROSS
HOLD
U.W.
W.
ZERO MODE
8
KEY : Use to move the inputted value to the left by one place. KEY: Use to input a decimal point.
KEY: Use to complete the input
Ex) For 20.5 input
DISPLAY KEY DESCRIPTION
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
ENTER
MODE
Press once (Set to 0 )
Press twice
(Input 2 as the
first place value)
Press once (Move to the left
by one place)
Press once
(Decimal point input)
Press five times
(Input 5 as the
first place value)
Input completion
SIMPLE WEIGHING MODE CONVERSION
DISPLAY KEY PLATFORM DESCRIPTION
Step 1
Step 2
Press once
Press once. Generally operated
ENTER
Empty
LO
kg
ENTER
MODE
9
DISPLAY KEY PLATFORM DESCRIPTION
Step 1
Step 2
Press twice
Press once Generally operated
ENTER
Empty
High/Low comparing mode conversion
In case of no resetting the High/Low value
In case of resetting the High/Low value
DISPLAY KEY PLATFORM DESCRIPTION
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Press twice
Press once (Low weight input)
Refer to digit input in page 8.
High value input
Refer to digit input in page 8.
Generally operated
ZERO MODE
Empty
kg
LO
kg
kg
kg
LO
10
DISPLAY KEY PLATFORM DESCRIPTION
Step 1
Step 2
Press three times
Press once. Generally operated
ENTER
Empty
COUNT MODE CONVERSION
In case of no setting the unit/sample weight
In case of setting the unit weight
(Min. range of unit weight : Min. Division)
DISPLAY KEY PLATFORM DESCRIPTION
Step 1
Step 2
Step 3
Step 4
Step 5
Press three times
Press once
Display the set weight
Input the unit weight
Press ‘Mode’ key to round and display unit weight. Generally operated.
pcs
kg
kg
pcs
MODE
MODE
MODE
Set digit input in page 8.
Step 5. Ex) Min. division is 0.1 Input the unit weight as 0.532 and round off the second place of decimal to 0.5.