Carter Hoffman NCW105 Parts List

Page 1
6. Brush any crumbs down into the bottom
12" x 20"
clean out pan.
10
11
Since 1947,
Foodservice Equipment That Delivers!
For Model
Turn off power, unplug cabinet, and allow to cool before
Cleansers, deter
1. To clean stainless steel surfaces use only cleansers, detergents,
2.
3.
4.
5.
FIGURE 1 FIGURE 2
Cleaning, Operating, Maintenance Instructions, Parts List & Warranty
NCW105 Chip Warmer
Daily Cleaning Instructions
NOTE :
This equipment has been designed and manufactured to meet alt applicable health and safety codes and will give years of dependable service if used properly. All carts should be thoroughly cleaned before
using.
gents, degreasers, sanitizers, or
CAUTION bleaching agents
that contain chlorides or phosphates will cause permanent damage to stainless steel products. The damage appears as pits, eruptions, voids, small holes, cracks, severe discol­oration, or dulling of the metal finish. Water with high chloride content can also damage stainless steel. If unsure of your water quality, we recommend you have it tested. THIS DAMAGE IS PERMA­NENT, COSTLY TO REPAIR, AND IS NOT COVERED BY THE WARRANTY.
cleaning. Heating element should not be exposed to direct contact with water or cleaning sprays. Permanent damage
WARNING to the electrical components will result.
degreasers, or sanitizers that are certified to be "chloride-free" and "phosphate -free," and cleansers, degreasers, or sanitizers only in the recommended concentrations. DO NOT exceed recommended concentrations or mixing ratios. After cleaning and sanitizing, rinse all exposed surfaces thoroughly with large amounts of clean, clear water. Wipe off any standing liquid or residue from all surfaces, corners, or near edges.
Remove leftover chips from unit. Do not store chips in cabinet overnight.
Allow cabinet to cool.
Remove the bottom chip cover. (See figure 1.) Open up the bottom clean cover. (See figure 2.)
(Not supplied.)
7. Wipe down all the cabinet interior surfaces to remove any grease.
8. Close the bottom clean out cover and replace bottom 12" x 20" clean out pan.
9. Replace the bottom chip cover. The unit is now ready to be used for the next business day. Follow monthly cleaning procedures on page 3.
Page 2
RECOMMENDED "TIPS" FOR CLEANING STAINLESS STEEL
Heater/Cabinet
Purpose Frequency Cleaning Agent Method of Application
Routine Daily Soap, ammonia detergent Sponge with cloth, rinse with clear water and wipe dry. cleaning
Smears/ As Needed Stainless steel cleaner Rub with cloth as directed on package. Rub in direction fingerprints
Stubborn Daily Any chloride-free Apply with damp sponge or cloth. Rub in direction of polish spots and As Needed or phosphate-free lines. Rinse thoroughly after use, especially if cleaner
stains Hard water Daily Vinegar Swab with cloth. Rinse with water and wipe dry.
spots As Needed
CAUTION: Do not use steel wool pads as they will result in rusting from the ferrous metal in the pads.
Operations
NOTE:
The cabinet is factory set to operate at 180° F.
and water
or similar products of grain of stainless steel. Do not use on vinyl trim.
cleaner contains chlorine bleach. Do not use on vinyl trim.
1. Install 12" x20" pan (not supplied) under clean out cover. (See figure 3.)
2. Before using, familiarize yourself with the cabinet controls.
3. Turn the cabinet on.
FIGURE 3
4. Wait 30 minutes for the cabinet to preheat.
5. Load the cabinet with chips. For best results and mo st uniform heating it is important to preheat the cabinet before loading.
6. Allow the chips to heat for 30 minutes before serving.
7. Serve chips by unloading from the bottom door.
8. Reload the cabinet when chips are nearing the bottom to ensure there are always hot chips available. Remember, new chips will require at least 30 minutes to heat before using.
9. At the close of the business day, perform the daily cleaning procedures.
2
Page 3
Calibrations
[A]
MONTHLY CLEANING PROCEDURES
Maintenance
NOTE
:
[A] THERMOSTAT CALIBRATION
If additional heat range is required in the cabinet and the thermostat is turned up all the way, follow these procedures to increase the calibration range. Unplug unit and remove the two screws that hold the access cover on and set aside. Insert small straight blade screwdriver into opening and turn limit control set screw counter clockwise (not clockwise) one full turn. Replace thermostat knob and turn clockwise to reach new maximum temperature. Repeat this until desired temperature is reached. Each 1/4 turn of the calibration set screw will raise the element heating capacity by approximately 25°F-35°F.
If a reduction of heat is desired, turn limit control set screw clockwise one full turn. Hold the door open allowing unit to cool until inside temperature is below the temperature desired. Close the door and allow unit to rise to new maximum temperature. Repeat this until desired temperature is reached.
Instructions
Make sure the power is
off and chip WARNING warmer is at room temperature before performing this procedure.
Chips and dust will accumulate inside the element cover and on the fan access cover. These items need to be cleaned to ensure proper air flow and
cabinet performance.
1. Remove all chips from the cabinet. Do not store chips in the cabinet overnight.
2. Allow the cabinet to cool before cleaning.
3. Remove the bottom chip cover and set aside. (See figure 4.)
4. Remove the upper hopper by pushing in on the sides to disengage from the cabinet. (See figure 5.) When disengaged, gently drop hopper cover down. (See figure 6.)
5. Remove the Heat Element cover and take to the sink to be washed. Replace when dry and clean. (See figure 7.)
6. Remove the fan access cover. (See figure 8 & 9). Figure 8 is a photo of the fan access cover as it leaves the factory. Photo 9 is of an actual cabinet in service. At the sink spray off all the accumulated crumbs. Set aside to air dry. If there are any chips or dust inside the fan area, with the use of a vacuum, clean out the chips. (See figure 10.) When clean replace the fan access cover. (See figure 11.)
NOTE: Failure to clean this cover monthly will result in poor air
circulation (cold chips) and will cause the safety hi-limit to trip. This expensive service call can be avoided if these procedures are followed.
7. Wipe down the cabinet and replace any remaining parts.
8. Document this procedure and schedule next months cleaning in your planner.
3
Page 4
4
Page 5
Replacement Parts
Item Part Number
Description
Item Part Number
Description
1 16501
-
8083 Strike and Handle
7
18600
-
0010 Thermostat
2 16000
-
1042 Top Door Assembly
18601
-
1170 Red Glowlight
3 16000
-
1040 Bottom Door Assembly
8
16095
-0863 Door Holder
4 18605
-
0010 16/3 Cord with Plug
9
16090
-
0797 Door Hinge Assembly
5 18612
-
0210 Heat Element
10
16501
-
6943 Element Cover
A) 18614
-
0320 Fan Motor
11
16501
-
4887 Clean out Cover
B)) 18614
-
0321 Fan Wheel
12
18600
-
0046 300°F Auto Reset Hi L
imit 6 18602
-
0030 On/Off Switch
11000
-
0734 120 Volt Wiring Diagram
18601
-
1150 Red Pilot Light
11000
-
1244 220 Volt Wiring Diagram
Item Part
Description
Qty.
1 18600
-
0010 Thermostat
1
2 18600
-
0046 Hi-Limit 1
3 18601
-
1150 Red Pilot Light (250 V)
1 4
18601
-
1170 Red Glow
-
Light (120 V)
1
5 18602
-
0030 On/Off Toggle Switch (20 AMP)
1
6 18604
-
0010 14 Gage Teflon Black
3' 7
18604
-
0020 14 Gage Teflon White
3' 8
18604
-
0050 14 Gage MICA Glass Wire
7'
9 18605
-
0010 Power Cord with Plug
1
10 18807
-
0039 Insul. High Temp Terminal
2 11
18807
-
0050 High Temp Terminal 10
-
12 #10 Stud 2
12 18807
-
0061 Continuous Terminal
4
13 18807
-
0071 Splice Cap Insulate
2 & -0070 14 18807
-
0170 Solderless Connector
2 15
18807
-
0201 Butt Connector
2 16
18807
-
0207 Female Terminal (14/16 Gage)
2 17
18812
-
0210 Heat Element (118 V, 1500 W))
1
18 18814
-
0320 Motor (120,208,220,
1
230,240 50/60 Hz)
NCW-105 CHIP WARMER
Contact factory with your model and serial number for replacement cabinet components.
Wiring Diagram
Wiring Diagram NCW-105 (120 Volt)
Page 6
Item Part
Description
Qt
1 18600
-
0010 Thermostat
1
Wiring Diagram NCW
-
105(220Volt)
FEBRUARY
1998
2 18600-0046 Hi-Limit 1 3 18601-1150 Red Pilot Light (250 V) 1 4 18601-1160 Red Glow-Light (250 V) 1 5 18602-0030 On/Off Toggle Switch (20 AMP) 1 6 18604-0010 14 Gage Teflon Black 3' 7 18604-0020 14 Gage Teflon White 3' 8 18604-0050 14 Gage MICA Glass Wire 7' 9 18605-0010 Power Cord with Plug 1 10 18807-0039 Insul. High Temp Terminal 2 11 18807-0050 High Temp Terminal 10-12 #10 Stud 2 12 18807-0061 Continuous Terminal 4 13 18807-0071 Splice Cap Insulate 2
& -0070 14 18807-0170 Solderless Connector 2 15 18807-0201 Butt Connector 2 16 18807-0207 Female Terminal (14/16 Gage) 2 17 18612-0190 Heat Element (220 V, 1700 W) 1 18 18814-0320 Motor (120, 208, 220, 1
230, 240 50/60 Hz)
Carter-Hoffmann Corporation Warranty:
Carter-Hoffmann Corporation ("CARTER-HOFFMANN") warrants to the initial purchaser of its standard Carter Line Products that CARTER-HOFFMANN uill. at its option, repair or replace, during the warranty period set forth below, any part of such products made necessary due to a defect in material or workmanship which is present when the product leaves its factory and which manifests itself during the warranty period under normal use and sen'ice.
This warranty applies only to original equipment owned and possessed by the initial purchaser and the warranty period begins on the date of original shipment from the CARTER-HOFFMANN factory and extends as follows: to electrical and refrigeration
components for one year; to electrical and refrigeration labor for 120 days; to refrigeration compressor unit for 1 year (limited to replacement of the unit only—not to include labor for removal, repair or replacement), and to all other component
parts and labor for 12 months. Repair or replacements under this warranty will he Informed, unless otherwise authorized in writing by CARTER-HOFFMANN, at
its factory. All parts or components to be repaired or replaced under this warranty are to be shipped prepaid to CARTER­HOFFMANK, with reimbursement credit for such part or component to he given if found by CARTER-HOFPMA'vN to be defective.
CAKTER-HOFFMANH neither makes nor assumes and does not authorize any other person to make or assume any obligation or liability in connection with its products other than that covered in this warranty. This warranty applies only within the continental United States and Canada. In Alaska and Hawaii, this warranty applies only to and is limited to the supply of replacement parts.
Warranty Exclusions And Limitations:
Any implied warranty of merchantability or fitness for a particular purpose is hereby specifically disclaimed by Carter-Hoffmann Corporation. There are no warranties, expressed or implied, which extend beyond the description on the face hereof.
This warranty does not cover and CARTER-HOFFMANN shall not under any circumstances be liable for any incidental, consequential or other damages (such as injury to persons or property, loss of time, inconvenience, loss of use, loss of business or profits, or other matters not specifically covered) arising in connection with the use of, inability to use, or failure of these products.
Specifications subject to change through product improvement and innovation.
1551 McCormick Avenue, Mundelein, Illinois 60060 Tel. 1-800-323-9793 • Fax No. (847) 367-8981
Since 1947, Foodservice Equipment Tliot Delivers!