Carrier Access Adit 3500 User Manual

Page 1
Adit 3500
QUICK START GUIDE
Part Number: 002-0250-0010
Product Release: 1.6
September 2007
Page 2
Copyright 2007 Carrier Access Corporation. All rights reserved. The information presented in this manual is subject to change without notice and does not represent a commitment on the
part of Carrier Access Corporation. The hardware and software described herein are furnished under a license or non­disclosure agreement. The hardware, software, and manual may be used or copied only in accordance with the terms of this agreement. It is against the law to reproduce, transmit, transcribe, store in a retrieval system, or translate into any medium
- electronic, mechanical, magnetic, optical, chemical, manual, or otherwise - any part of this manual or software supplied with the Adit 3500 for any purpose other than the purchaser’s personal use without the express written permission of Carrier Access Corporation.
The Carrier Access Logo and Adit are registered trademarks of Carrier Access Corporation. All other brand or product names are trademarks or registration trademarks of their respective companies or organizations.
Contact Information: Carrier Access Corporation
5395 Pearl Parkway Boulder, CO 80301-2490 Corporate Phone: (303) 442-5455 Fax: (303) 443-5908 www.carrieraccess.com
Customer Support Direct: (800) 786-9929 E-mail: tech-support@carrieraccess.com
Page 3
QUICK START GUIDE
Quick Start Guide
In this Guide
Unpacking and Inspection Installation EnvironmentUser SafetyInstallation
- Compliant Installation
- Ferrite Beads
- Wall Mounting
- Rack Mounting
- Battery Backup
Chassis OverviewInterface ConnectorsReset ButtonAlarm/Status LEDsWeb-Based ManagementSetting up a CLI ConnectionLog inKey Enabled Software FeaturesBasic ConfigurationWeb-Based Management
- Restore Factory Defaults
- Modify Default Admin User
- Configure WAN Interface for Internet Connectivity
- Configure the Adit 3500 as a SIP Gateway
Page 4
Quick Start Guide

Unpacking and Inspection

Unpacking and Inspection
WARNING! OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC DEVICES.
1. Inspect containers for damage during shipment. Report any damage to the freight carrier for possible insurance claims.
2. Compare packing list with office records. Report any discrepancies to the office.
3. Open shipping containers, be careful not to damage contents.
4. Inspect contents and report any damage.
5. If equipment must be returned for any reason, carefully repack equipment in the original shipping container with original packing materials if possible.
6. If equipment is to be installed later, replace equipment in original shipping container and store in a safe place until ready to install.

Electrostatic Discharge (ESD) Precautions

ESD can damage processors, circuit cards, and other electronic components. Always observe the following precautions before installing a system component.
1. Do not remove a component from its protective packaging until ready to install it.
2. Wear a wrist grounding strap and attach it to a metal part of the system unit before handling components. If a wrist strap is not available, maintain contact with the system unit throughout any procedure requiring ESD protection.
WARNING! INTEGRATED CIRCUITS (ICS) ARE EXTREMELY SUSCEPTIBLE TO ELECTROSTATIC
DISCHARGE. UNLESS YOU ARE A QUALIFIED SERVICE TECHNICIAN WHO USES TOOLS AND TECHNIQUES THAT CONFORM TO ACCEPTED INDUSTRY PRACTICES, DO NOT HANDLE ICS.
The ESD warning label appears on packages and storage bags that contain static-sensitive products and components.
4 Adit 3500 - Release 1.6
Page 5
Quick Start Guide

Installation Environment

Installation Environment
The environment in which you are installing the Adit 3000 must meet the following conditions:
z Operating temperature range: 32° to 104° F (0° to 40° C) z Storage temperature range: -40° to 158° F (-40° to 70° C) z Maximum operating altitude: 10,000 ft. (3,048 m) z Maximum non-operating altitude: 40,000 ft. (12,192 m) z Relative humidity (non-condensing) range: 0 to 95%
WARNING! THE ADIT 3000 IS DESIGNED FOR WALL AND RACK MOUNTING ONLY. IT IS NOT
DESIGNED FOR DESKTOP USE.

User Safety

CAUTION! WHEN USING YOUR TELEPHONE EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD
ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO PERSONS, INCLUDING THE FOLLOWING:
z Do not use this product near water for example, near a bathtub, washbowl, kitchen sink or
laundry tub, in a wet basement or near a swimming pool.
z Avoid using a telephone (other than a cordless type) during an electrical storm. There may be
a remote risk of electric shock from lightning.
z Do not use the telephone to report a gas leak in the vicinity of the leak. z Use only the power cord and batteries indicated in this manual. Do not dispose of batteries in a
fire. They may explode. Check with local codes for possible special disposal instructions.
z Refer to the installation section of this manual for a safe and proper installation procedure. All
wiring external to this equipment should follow the current provision of the National Electrical Code.
Adit 3500 - Release 1.6 5
Page 6
Quick Start Guide

Installation

Installation
The following are instructions for a compliant installation of the Adit 3500. Please note the following warnings, before installing the unit.
For wall and rack mount instructions, use the links listed below to the appropriate section:
z Wall Mounting z Rack Mounting z Battery Backup
WARNING! OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC DEVICES. SEE
Electrostatic Discharge (ESD) Precautions ON PAGE 4 FOR DETAILED INFORMATION.
WARNING! THE ADIT 3500 DS1 NETWORK INTERFACE PORTS ARE CERTIFIED WITH ACTA,
I
NDUSTRY CANADA AND UL FOR DIRECT CONNECTION TO PUBLIC DIGITAL NETWORKS. TO PREVENT EQUIPMENT DAMAGE FROM LIGHTNING SURGES, AC INDUCTION OR POWER LINE CONTACT, UTILIZE LISTED PRIMARY PROTECTORS AT THE BUILDING ENTRANCE WITH MINIMUM 4 OHM CURRENT- LIMITING AND MAXIMUM 600V IMPULSE BREAKDOWN AT 1000V/USEC. THE ADIT 3500 DS1 PORTS COME EQUIPPED WITH SECONDARY OVERVOLTAGE AND OVERCURRENT PROTECTION. THE INSTALLATION IS REQUIRED TO MEET LOCAL OR NATIONAL ELECTRIC CODES FOR COMMUNICATION SYSTEMS.
WARNING! THE ADIT 3500 FXS INTERFACE PORTS ARE INTENDED TO SERVE INDOOR
COMMUNICATION CONDUCTORS ONLY. OVERVOLTAGE AND OVERCURRENT PROTECTION IS PROVIDED TO PREVENT EQUIPMENT DAMAGE FROM LIGHTNING SURGES OR AC POWER LINE CONTACT INSIDE BUILDINGS. THE FXS PORTS ARE NOT SUITABLE FOR CONNECTION TO EXPOSED OUTDOOR COMMUNICATION CONDUCTORS.
6 Adit 3500 - Release 1.6
Page 7
Quick Start Guide
Installation

Compliant Installation

NOTE: It is important the DS1/E1 Network Interface Cables are secured separately from the
power and Signal Cables.
1. Inspect the unit.
2. Mount the unit.
z Wall mounting installation, see Wall Mounting on page 9. z Wall mounting with Battery Backup Unit, see Battery Backup on page 12. z Rack mounting installation, see Rack Mounting on page 10.
3. Ground the unit.
WARNING! THE ADIT 3500 IS REQUIRED TO BE PERMANENTLY GROUNDED FOR THE
PROTECTION OF USERS AND SERVICE PERSONNEL. REFER TO Grounding the Unit ON PAGE 3 FOR DETAILED INSTRUCTIONS.
4. Connect DS1 (T1), and Ethernet connections as needed.
5. Connect RS-232 connector and connect via HyperTerm on your PC. Note: With this running before power is enabled, you can monitor the boot process.
6. Attach PBX and phone line cables.
7. Connect Power to the unit.
8. Monitor the boot process on your PC, when complete the status light should be green.
9. For any software enabled features, enter the key command. See the key command in the Adit 3000 CLI Reference Manual, for detailed information.
10. To verify use the show version command.
11. To provision the unit. See Web-Based Management on page 23, for detailed instructions.
Adit 3500 - Release 1.6 7
Page 8
Quick Start Guide
12V Power Cord
Loop through Ferrite Bead
Ferrite Bead
Back of Adit 3500
Installation

Ferrite Beads

The following ferrite bead is required on the Adit 3500 configurations that do not have the FXS 4 channel option. The ferrite bead will enable the Adit to be compliant with EMI standards FCC Part 15 and ICES-003 Class A.
Ferrite beads shipped with Adit chassis:
Ferrite Provided Part Number Intended For
1 large P/N 010-0051 Power cable, which requires a loop through the bead (see
drawing).
For additional information on Ferrite beads and their installation on the Adit 3500, please contact Carrier Access Customer Support at (800) 786-9929.
8 Adit 3500 - Release 1.6
Page 9
Quick Start Guide
Mounting Bracket
Leave adequate space at the front/back for access to connectors
Back of unit
Front of unit
Installation

Wall Mounting

Before beginning the mounting process, verify that the installation area is a stable environment, clean and free from extremes of temperature, shock, vibration and EMI. See Installation Environment on page 5.
The Adit 3000 is delivered with mounting brackets that can easily be attached for quick and easy wall mounting, as shown in the illustration above.
To install the unit to the wall:
1. Attach the wall mount brackets to the Adit 3000, with wall attachment flange pointing away from the unit, as shown above. Attach with 4 screws provided (2 for each bracket).
2. Mount the unit to the wall using appropriate mounting screws (not included). Note: it is acceptable to mount on drywall with suitable anchor-type mounting screws.
NOTE: The Adit 3000 must be mounted with the brackets on the top and bottom, as
shown above.
Adit 3500 - Release 1.6 9
Page 10
Quick Start Guide
23 in rack
19 in rack
Front
Front
screws
screws
screws
screws
Rack Mount Tray
Rack Mount Tray
Mounting Ear
Mounting Ear
Mounting Ear
Mounting Ear
Mounting Ear
Rack Mounting Tray
Installation

Rack Mounting

This is an Optional Feature.
NOTE: Rack mounting kits are available for both 19 and 23 inch racks. 1 Rack Unit (RU) of spacing
is required above the Adit 3000 in the Rack Mount Unit.
To rack mount the Adit 3000, follow the instructions below:
1. Attach bracket ears to Rack Mounting Tray using four #10-32 x 1/4" screws on each side. The Mounting Ears can be used for both a 19 or 23 inch rack. The drawing below shows a top view of the 2 versions.
2. Attach the Rack Mounting Tray assembly (with mounting ears attached) to rack, using four
10 Adit 3500 - Release 1.6
3. Remove wall mount and screws, if attached, from Adit 3500 unit.
#10-32 x 1/4” screws (two on each mounting ear).
Note: Adit 3500 and wall mounting bracket are not assembled from the factory.
Page 11
Quick Start Guide
Tray Slide
screws
screws
Installation
4. Place the Adit 3000 on the Tray Slide and attach with the 4 screws removed in step 2.
5. Slide the assembled piece (Adit 3000 and Tray Slide) onto the installed Rack Mounting Tray.
6. Secure the Tray Slide to the Rack Mounting Tray with the attached screws on the Tray Slide.
NOTE: The mounting brackets are designed to not allow units to be mounted closer than
recommended.
Adit 3500 - Release 1.6 11
Page 12
Quick Start Guide
Option 2
Adit 3500

Battery Backup

Option 1
view from side
Wall
Installation
Battery Backup
This is an Optional Feature. The Adit 3500 Battery Backup is
designed specifically for the Adit 3500. The battery backup unit is a single 12V sealed lead-acid battery in a metal enclosure designed for wall mounting.
Installation
There are two possible configurations to wall mount the Adit 3500 and the Battery Backup.
NOTE: It is recommended that the BBU be mounted to a wooden backboard using (4) #6
screws, or to drywall using (4) #6 screws with anchors. These screws are not provided.
1. Battery Backup attached to wall, with Adit 3500 mounted on the Battery Backup
2. Adit 3500 and Battery Backup attached to wall.
12 Adit 3500 - Release 1.6
Page 13
Quick Start Guide
Wall Brackets
Power Cord Holder
Installation
#1 Adit 3500 mounted on top of the Battery Backup
This method will use a minimal amount of wall space. Note: This installation will require a minimum wall space of space of: 9" (H) x 14" (W) x 5" (D).
1. Mount the Battery Backup to the wall with
(4) #6 x 1 coarse thread screws Note: Screws are not provided
z Mark the location for the top 2 screws
(using BBU mounting keyhole as a guide)
z Screw these 2 screws into the wall at
marked locations. Note: do not screw tight to the wall, leave 1/4" to allow BBU mounting keyholes to slip over screw head.
z Attach the BBU by slipping the screw
heads through the keyhole slots of the BBU, and let unit drop slightly to allow screwheads to enter top of the keyhole.
z Screw bottom 2 screws into mounting
holes at the bottom of the unit.
z Tighten all screws to the wall.
2. Attach Adit 3500 Wall Mounting
Brackets to the BBU. Note: Brackets are provided with the Adit 3500 unit.
z Each bracket is attached to the outer
facing side of the BBU. Note the bracket orientation in the graphic.
3. Insert Adit 3500 Power cord through
the holder on the right. This supports the weight of the adapter portion of the power cord.
z The connector to the wall runs out
the bottom, while the connector to the Adit 3500 will run out of the top.
Adit 3500 - Release 1.6 13
Page 14
Quick Start Guide
Front of Adit
Screws into side of Adit
Second bracket here
Installation
4. Attach Adit 3500 to the assembled BBU and brackets.
z Each bracket attaches to the side of
5. Attach power cords.
z Connect cord from BBU to the Adit
z Connect 12V power cord to Adit
the Adit 3500. Note the orientation of the Adit in the graphic.
3500 (2 pin connector).
3500.
14 Adit 3500 - Release 1.6
Page 15
Quick Start Guide
Adit 3500
Battery Backup
Front
Back
Holds AC Adapter portion of power cord
Battery Cable
Installation
#2 Adit 3500 and Battery Backup mounted to the wall
This method requires a more wall space. Note: This installation will require a minimum of wall space of: 17" (H) x 14" (W) x 2.5" (D).
1. Mount the Battery Backup to the wall with (4) #6 screws, by:
z Mark the location of the left-side 2 screws (using the BBU mounting keyhole as a guide).
Note: this installation of the BBU is oriented with the mounting keyholes to the left side.
z Screw these 2 screws into the wall at marked locations. Note: do not screw tight to the wall,
leave 1/4" to allow BBU mounting keyholes to slip over screw head.
z Attach the BBU by slipping the screw heads through the keyhole slots at the left of the
BBU, and slide unit to the right to allow screwheads to enter the narrow end of the keyhole.
z Screw the second set of 2 screws into mounting holes on the right of the unit. z Tighten all screws to the wall.
2. Insert Adit 3500 Power cord through the holder on the top of the BBU. This supports the
weight of the adapter portion of the power cord.
3. Attach Adit 3500 to the wall following the instructions, Wall Mounting on page 9.
Attaching the Adit 3500 to the wall above the BBU. Note: there is a distance limit between the Adit and the BBU (note the length of the battery cable to the Adit).
4. Attach power cords.
z Connect cord from BBU to the Adit 3500 (2 pin connector). z Connect 12V power cord to Adit 3500.
Adit 3500 - Release 1.6 15
Page 16
Quick Start Guide
(2) 10/100Base-T
(4) DS1/E1
(4) Analog (FXS) connectors
Alarm Status
Reset
RS-232 Management Port
Power
Ground
Back
Front
Battery
(E1 Future)

Chassis Overview

Adit 3500 Battery Backup Power Connector
The following cable, is hard wired to the Adit 3500 Battery Backup and connects the Adit 3500.
Pinout Wire
Chassis Overview
The following illustrations show all connectors on the Adit 3500.
Definition
Red 12V (+) Black 12V (-)
16 Adit 3500 - Release 1.6
Page 17
Quick Start Guide
Chassis Ground

Interface Connectors

Interface Connectors
The following are the Adit 3500 interface connectors: Note: The following is dependant upon how the system (hardware) is configured. Systems can be
ordered with/without FXS, and can have from 1-4 DS1 ports.
Front of Adit
z 4 DS1 Ports (used for DS1 WAN and/or PRI/CAS trunks) (RJ-45C connector).
- (1) T1-based WAN - uses 1 or 2 DS1 ports
- (1) PRI/CAS group - uses 1 or 2 DS1 ports
z (1) 10/100Base-TX WAN port (RJ-45 connector) z (1) 10/100Base-TX LAN port (RJ-45 connector) z 4 FXS (RJ-11 connector)
Back of Adit
z RS-232 craft port connector for local management z Power input connector z Battery input connector z Ground connector

Grounding the Unit

WARNING! THE ADIT 3500 IS REQUIRED TO BE PERMANENTLY GROUNDED FOR THE
PROTECTION OF USERS AND SERVICE PERSONNEL.
Chassis ground is located on the back of the unit. To ground the unit:
1. Connect a minimum 14 AWG ground
wire with a #8 ring tongue terminal (not included) to the chassis ground on the back of the unit. Secure with the 8-32 screw and lock washer provided.
2. Connect the opposite end of the ground
wire to a suitable earth grounding point such as a building grounding electrode, metal water pipe, or metal building structure that is in compliance with article 250 of NEC.
Adit 3500 - Release 1.6 17
Page 18
Quick Start Guide
Interface Connectors

12 VAC Power Connection

The Adit 3500 is powered by a 12 VAC Power Converter, which provides 12 VDC to the unit.
Item Specification Input
Output
Rate input voltage AC100V-240V
Vibration input voltage range AC90V-255V
Frequency Rated 50-60 Hz
Frequency Vibration 47-63Hz
Input rated current 15A max. at 115VAC cool start
Leakage current 0.25mA
Efficiency 70% Min.
Output voltage 13.5VDC
Output max. current 2.2A+
Output min. current 0A (V out = 14VDC)
Line regulation +
Load regulation +
Short circuit protection Output shut down auto restart

Battery Connection

30A max. at 230VAC cool start
150mA (V out = 9VDC-13VDC)
1%
5%
The Battery connector on the Adit 3500 is a 2 pin connector provided specifically for the Battery Backup option. See Battery Backup on page 10 for additional information.
18 Adit 3500 - Release 1.6
Page 19
Quick Start Guide
18
Interface Connectors

DS1/E1 Connection Ports

Each DS1/E1 connection port is equipped with a standard RJ-48C (female) on the Adit 3500 unit. Note: E1 will be available in a future release.
The pinouts are as follows:
DS1/E1 RJ-48C
The pinouts are as follows:
Pin Name Description
1 Receive Ring Receive from DS1 network 2 Receive Tip Receive from DS1 network 3 N/C Not connected 4 Transmit Ring To DS1 network 5 Transmit Tip To DS1 network 6 -8 N/C Not connected
The LEDs are as follows (left LED only):
State Description
Off Off line Green Normal Red Loss of Signal (LOS) Yellow Bipolar Violation (BPV) Flashing Green Loopback active Flashing Yellow Yellow Alarm (Remote Alarm Indication) Flashing Red (Slow) Loss of Frame (LOF) or Alarm Indication Signal (AIS) Flashing Red (Fast) Self-test Failure
Adit 3500 - Release 1.6 19
Page 20
Quick Start Guide
18
Interface Connectors

10/100Base-TX Ethernet

The 10/100Base-TX Ethernet (female) ports provide connectivity for Router WAN and/or LAN ports and for management connection via Telnet and/or SNMP to a Network Management System.
Ethernet (RJ-45)
The pinouts are as follows: Note: This is a hub pinout, you will need a straight cable to connect to a PC.
Pin Name Description
1 Receive + Receive from network 2 Receive - Receive from network 3 Transmit + Transmit to network 4-5 N/C Not connected 6 Transmit - Transmit to network 7-8 N/C Not connected
The LEDs are as follows:
LED State Description
Left LED The left LED shall show Link Status.
Off Link Down Green Link Up Flashing Green Traffic on Link Yellow Collision status
Right LED The right LED shall indicate Link Speed.
Off 10 Mbit/sec, down or not connected Green 100 Mbit/sec
20 Adit 3500 - Release 1.6
Page 21
Quick Start Guide
15
69
16

Reset Button

RS-232 Craft Port (Female DB-9)

The RS-232 craft port connector (female) is for connection to an external PC or Hayes-compatible modem for local or remote configuration, management, and performance monitoring using the Adit 3500 Command Line Interface (CLI).
The RS-232 craft port connects via a female DB-9 connector on the Adit
3500.
The pinouts are as follows:
Pin Direction Description
1 Outbound Carrier Detect 2 Outbound Receive Data 3 Inbound Transmit Data 4 Inbound Data Terminal Ready 5 N/A Signal Ground 6 Outbound Data Set Ready 7 Inbound Request to Send 8 Outbound Clear to Send 9 N/C Not connected

RJ-11 Connector

There are four RJ-11 (female) connectors for the FXS ports.
The pinouts are as follows:
Pin Name Description
1 - 2 N/C Not connected 3 R Ring 4 T Tip 5 - 6 N/C Not connected
Reset Button
The system can be reset by pressing the reset button located on the front panel.
Adit 3500 - Release 1.6 21
Page 22
Quick Start Guide

Alarm/Status LEDs

Alarm/Status LEDs
LED State Description
Critical Off No critical alarms present
Red Critical alarms present. Critical alarms include:
Major Off No major alarms present
Red Major alarm present. Major alarms include:
Minor Off No minor alarms present
Red Minor alarms present. Minor alarms include:
Status Off No power to system
user-configured manor environmental inputs.
user-configured manor environmental inputs, DS1 short, DS1 open, DS1 facility alarm, DS1 RAI, DS1 AIS, DS1 LOF, DS1 LOS, WAN fault, Ethernet fault and dead card alarms.
user-configured manor environmental inputs, DS1 excessive line code violations.
Green Application running, no detected system problems.
Green Flashing Power-On Self Test (POST) successful. System booted. Loading Application.
Green/Yellow Flashing alternate colors. Application Self Test in Process.
Yellow Yellow while booting. If this stays a steady yellow the Power-On Self Test
(POST) failed.
Yellow Flashing Power-On Self Test (POST) In Process.
Red System Failure
22 Adit 3500 - Release 1.6
Page 23
Quick Start Guide

Web-Based Management

Web-Based Management
The web-based management interface allows you to control various system parameters. The interface is accessed through a web browser.

To access the management console:

NOTE: The following assumes that you have connected the PC to the LAN port of the Adit
3500.
1. Launch a web browser on your PC in the LAN to which the Adit 3500’s LAN port is connected.
Note: If connection to the 3500 is to be through an Ethernet or T1 WAN, the remote admin WAN access must be enabled with the following command sequence:
Command Description
Username: admin Password: ********
Adit 3500> enable Enter the Privileged mode.
Password: ********
#configure terminal
(config)# remote-admin web
primary-port enable
Log into the system (username and password).
Enter password for the Privileged mode.
Enter the Configuration mode.
Enable remote web admin.
2. Type the Adit 3500’s IP address or name in the address bar.
Example: http://192.168.1.1.
z Default IP address is http://192.168.1.1
Note: to display the current IP address of the systems, use the following CLI command:
#show interface ethernet 1 (LAN) #show interface ethernet 2 (Eth WAN)
3. Login to the unit.
Enter User Name and Password. Note: these setting should be changed from the default settings after the initial login.
z Default user name is admin z Default password is admin 123
NOTE: After a few minutes of inactivity, the session will automatically timeout and the
operator will be required to log in to continue the session.
WARNING! IF YOUR USER NAME AND PASSWORD ARE SET TO THE DEFAULT SETTING, IT IS
RECOMMENDED THAT YOU MODIFY THEM FOR SECURITY PURPOSES.
Adit 3500 - Release 1.6 23
Page 24
Quick Start Guide

Setting up a CLI Connection

Setting up a CLI Connection
A CLI connection will require the LAN or WAN IP address of the unit. Note: If the WAN IP address is used, the remote admin WAN access must be enabled with the following command sequence:
Command Description
Username: admin Password: ********
Adit 3500> enable Enter the Privileged mode.
Password: ********
#configure terminal
(config)# remote-admin web primary-
port enable
Log into the system (username and password).
Enter password for the Privileged mode.
Enter the Configuration mode.
Enable remote web admin.
NOTE: For Adit 3500 CLI commands see the Adit 3000 CLI Reference Manual. This is a
separate document and can be found on the CD that is provided with the product, or on the Carrier Access customer website.
To connect with CLI, set up the connection:
z If connecting via the Ethernet 100Base-TX connection, use a Telnet TCP/IP program to access
the CLI. This requires an IP address of the unit. Note: to display the current IP address of the unit, use the ifconfig command.
z If connecting via RS-232, the port settings should be set to:
Bits per second: 115200 Data bits: 8 Parity: None Stop bits: 1 Flow control: None
z Set your Terminal Emulation to: VT100
NOTE: When using Tera Term (Telnet program) TCP/IP, CLI commands will not be
recognized until the following setup is completed.
z In Tera Term go to Setup/Terminal z Set the New-line/Transmit value CR+LF
24 Adit 3500 - Release 1.6
Page 25
Quick Start Guide

Log in

Log in
After successful connection, via telnet or HyperTerm, the user must login. Default Logins are:
Login: admin Password: admin123
After successful login the prompt will be displayed as follows:
Adit 3500>
NOTE: It is recommended that you change your password from the default.

Key Enabled Software Features

The Adit 3500 has additional features that are not provided on the base system. These features can be purchased with the product or added later as needed. These features are enabled via a Software Key (example: G.729). The number of keyed features may expand with the development of the product, therefore to see a list of current keyed features, or to purchase a key, contact Carrier Access Customer Service or Sales.
To enter a software key, use the following CLI command:
Syntax:
Example: (config)# key cxusdfutkj3diosn412C
(config)# key key-code
NOTE: Keys may only be entered through the CLI (not through the GUI).
The Key Enabled Software Features are displayed on the Advanced/Technical Information window.
Adit 3500 - Release 1.6 25
Page 26
Quick Start Guide
Key Enabled Software Features
This information is also displayed with the following CLI command:
Adit 3500> show version
Application Version: 1.5.0 Compilation Time: Thu Jun 14 2007 18:07:22 FPGA Version: 1.00 Board Version: 5 003-1215-0300 IXP400 Software Release: 1_4 SQA4_1 MSP: 82530 - 60 channels Image File Name: TGW_v5_05.axf API Version : 2.1.0 Source IP Addr : 192.168.1.1 Voice Slot 1 : FXS Card Present: Rev 3.00 Vendor: Carrier Access CLEI Code: IPMHX00LRA
Product Features: SIP enabled. G729A enabled.
26 Adit 3500 - Release 1.6
Page 27
Quick Start Guide

Basic Configuration

Basic Configuration
The following configuration is divided into logical sections, where each section configures an additional function. The first must be configured before the second and so forth, however, you may stop at any section and not add the following feature.
NOTE: The order in which commands are entered can affect the successful provisioning of
the Adit 3500.
z Setup Adit 3500 for access via Web-Browser z Restore Factory Defaults z Modify Default Admin User z Configure WAN Interface for Internet Connectivity z Configure the Adit 3500 as a SIP Gateway

Setup Adit 3500 for access via Web-Browser

The following steps will configure the Adit 3500 to allow access to the Web Browser for configuration, through the LAN (1) or WAN (2) 10/100Base-T Ethernet connections.
Note: for LAN access, no additional configuration is required to access the Adit using the web browser. To configure the WAN access:
1. Connect to the CLI via the DB-9 RS-232. See Setting up a CLI Connection on page 24.
2. Enable the remote admin WAN access with the following command sequence:
Command Description
Username: admin Password: ********
Adit 3500> enable Enter the Privileged mode.
Password: ********
#configure terminal
(config)# remote-admin web
primary-port enable
Log into the system (username and password).
Enter password for the Privileged mode.
Enter the Configuration mode.
Enable remote web admin.
Adit 3500 - Release 1.6 27
Page 28
Quick Start Guide
Basic Configuration

Restore Factory Defaults

If the unit is not out-of-the-box, you may want to verify that the unit is set to defaults. Note: this will reset the IP address back to the default setting of 192.168.1.1. In the web-browser:
z Select Advanced from the Navigation bar z Select Restore Defaults
z Select OK to restore defaults
28 Adit 3500 - Release 1.6
Page 29
Quick Start Guide
Basic Configuration

Modify Default Admin User

For security purposes it is recommended that the Administrator User be changed from the default settings.
Modify the Administrator User in the web-browser:
z Select Advanced from the Navigation bar z Select Users icon
z Select Administrator, to open the profile.
Adit 3500 - Release 1.6 29
Page 30
Quick Start Guide
Basic Configuration
z Modify the User information, and select OK to save. It is important to note that you need to
have a minimum of one user with Administrative Privileges. For users with other access levels, use the New User to add additional users on the system. Note: For security purposes, the password should be changed from the default setting.
z You will be required to login again, if you have modified the User Profile that you are logged
in with.
30 Adit 3500 - Release 1.6
Page 31
Quick Start Guide
Basic Configuration

Configure WAN Interface for Internet Connectivity

There are options to this WAN configuration. This is the connection to the end user’s internet provider. It can be the following:
z Single T1 (PPP) z Multiple T1s (Multilink) z Ethernet WAN
Single T1 (PPP)
To configure a single T1 utilizing PPP:
1. Select Network Connections from the Navigation bar.
2. Select (click) a T1 Interface (from T1 1 - T1 4) to configure, T1 1 is recommended.
Note: Using T1 1 and the preconfigured Serial 1 makes this configuration very simple. If you use T1 2-T1 4, you will need to delete the preconfigured Serial 1 and make a New Connection (Serial 1) based on the T1 2-T1 4 that you selected.
Adit 3500 - Release 1.6 31
Page 32
Quick Start Guide
Basic Configuration
3. Select the Settings button.
4. Set the proper Framing Type and Line Coding.
5. Select OK to apply the new settings and exit this window.
6. Select OK again to return to the Network Connections window.
32 Adit 3500 - Release 1.6
Page 33
Quick Start Guide
Basic Configuration
7. Select (click) the Serial 1 connection.
8. Select the Settings button.
Adit 3500 - Release 1.6 33
Page 34
Quick Start Guide
Basic Configuration
9. Set the following on the Configure Serial 1 window:
- Network Type to WAN (this is the default setting)
- PPP Authentication to your required preferences
10. Select OK to apply the new settings and exit this window.
11. Select OK again to return to the Network Connections window.
34 Adit 3500 - Release 1.6
Page 35
Quick Start Guide
Basic Configuration
Multiple T1s (Multilink)
To configure Multiple T1s utilizing Multilink PPP:
1. Select Network Connections from the Navigation bar.
2. Select (click) a T1 Interface (from T1 1 - T1 4) to configure.
3. Select the Settings button.
Adit 3500 - Release 1.6 35
Page 36
Quick Start Guide
Basic Configuration
4. Set the proper Framing Type and Line Coding.
5. Select OK to apply the new settings and exit this window.
6. Select OK again to return to the Network Connections window.
7. Repeat steps #1-6 for additional T1s required for the ML-PPP
8. Select (click) the delete icon associated with the Serial 1 connection. Select OK to confirm the deletion of this connection.
36 Adit 3500 - Release 1.6
Page 37
Quick Start Guide
Basic Configuration
9. Select (click) New Connection to create the ML-PPP connection.
10. Select the Multilink Point-to-Point Protocol over DS0 (Multilink), and select Next.
Adit 3500 - Release 1.6 37
Page 38
Quick Start Guide
Basic Configuration
11. Enter User Name and Password.
12. Select the T1s for this Multilink and the channel ranges.
13. Select Next.
14. A summary of the Multilink connection will be displayed. If correct, select Finish.
38 Adit 3500 - Release 1.6
Page 39
Quick Start Guide
Basic Configuration
15. The new Multilink connection will display on the Network Connections window.
16. Select (click) the Multilink 1 connection.
17. Select the Settings button.
Adit 3500 - Release 1.6 39
Page 40
Quick Start Guide
Basic Configuration
18. Set the following on the Configure Multilink 1 window:
- Network Type to WAN (this is the default setting)
- PPP Authentication to your required preferences
19. Select OK to apply the new settings and exit this window.
20. Select OK again to return to the Network Connections window.
40 Adit 3500 - Release 1.6
Page 41
Quick Start Guide
Basic Configuration
Ethernet WAN
To configure the WAN utilizing Ethernet feed:
1. Select Network Connections from the Navigation bar.
2. Select (click) the delete icon associated with the Serial 1 connection.
Select OK to confirm the deletion of this connection.
3. Select (click) the Ethernet 2 (WAN Ethernet) connection to configure.
Adit 3500 - Release 1.6 41
Page 42
Quick Start Guide
Basic Configuration
4. Select the Enable button, to configure the WAN Ethernet up (or in-service).
5. Select the Settings button.
6. Set Network type to WAN.
7. Set Internet Protocol option (method of IP address assignment).
8. Select OK to apply the new settings and exit this window.
9. Select OK again to return to the Network Connections window.
42 Adit 3500 - Release 1.6
Page 43
Quick Start Guide
Basic Configuration

Configure the Adit 3500 as a SIP Gateway

1. Select Voice Over IP from the Navigation bar.
Adit 3500 - Release 1.6 43
Page 44
Quick Start Guide
Basic Configuration
2. On the IP Telephony tab, under Proxy Servers:
- Set Proxy Type to Generic/custom (BroadSoft or Sylantro). Example: BroadSoft
- Select Use SIP Proxy and enter SIP Proxy IP address
- Select supported Codecs
3. Select Apply to save the new settings.
4. Select the Advanced button.
44 Adit 3500 - Release 1.6
Page 45
Quick Start Guide
Basic Configuration
5. Modify any advanced VoIP settings as needed and select Apply.
6. Select OK to exit window.
Adit 3500 - Release 1.6 45
Page 46
Quick Start Guide
Basic Configuration
7. If using the FXS ports, select the Phone Settings tab.
8. Select the Action icon on line #1 to edit.
46 Adit 3500 - Release 1.6
Page 47
Quick Start Guide
Basic Configuration
9. Enter the Phone Number in the User ID field.
10. Enter Authentication information as needed.
11. Select OK to apply and exit this window.
12. Select OK to acknowledge that with these changes, active calls will be dropped.
13. Repeat this step for each FXS Line.
Adit 3500 - Release 1.6 47
Page 48
Quick Start Guide
Basic Configuration
14. The current User ID of the FXS lines will display.
15. Select the Line Monitoring tab. This window displays the SIP status of the FXS ports. Note: When a telephone port is successfully registered the Registration Status column displays "Registered" in green."
16. Select the Trunk Settings tab.
17. Select (click) on the trunk to configure.
18. Set the Trunk Signaling type to PRI or CAS.
48 Adit 3500 - Release 1.6
Page 49
Quick Start Guide
Basic Configuration
19. Set the Signaling Type.
20. Select New Entry to assign numbers to your PRI interface(s).
Adit 3500 - Release 1.6 49
Page 50
Quick Start Guide
Basic Configuration
21. Enter the phone number range for numbers to be routed to the trunk interface for incoming SIP calls, on the Call Destination window. Use Strip and Prefix entries to translate the incoming destination number from SIP to the destination number to be sent to the PRI/CAS interface.
22. Select OK to save and exit this window. Note: this information will display at the bottom of the Trunk Settings window.
23. Select OK again to return to the Voice Over IP window.
50 Adit 3500 - Release 1.6
Page 51
Quick Start Guide
Basic Configuration
24. Select the Trunk Monitoring tab to view the status of any calls on the PRI.
Adit 3500 - Release 1.6 51
Page 52
Quick Start Guide
Basic Configuration
52 Adit 3500 - Release 1.6