Part Number: 002-0246-0010
Product Release: 1.6
September 2007
Page 2
Copyright 2007 Carrier Access Corporation. All rights reserved.
The information presented in this manual is subject to change without notice and does not represent a commitment on the
part of Carrier Access Corporation. The hardware and software described herein are furnished under a license or nondisclosure agreement. The hardware, software, and manual may be used or copied only in accordance with the terms of this
agreement. It is against the law to reproduce, transmit, transcribe, store in a retrieval system, or translate into any medium
- electronic, mechanical, magnetic, optical, chemical, manual, or otherwise - any part of this manual or software supplied
with the Adit 3200 for any purpose other than the purchaser’s personal use without the express written permission of
Carrier Access Corporation.
The Carrier Access Logo and Adit are registered trademarks of Carrier Access Corporation. All other brand or product
names are trademarks or registration trademarks of their respective companies or organizations.
Contact Information:
Carrier Access Corporation
5395 Pearl Parkway
Boulder, CO 80301-2490
Corporate Phone: (303) 442-5455
Fax: (303) 443-5908
www.carrieraccess.com
Customer Support Direct: (800) 786-9929
E-mail: tech-support@carrieraccess.com
Page 3
QUICK START GUIDE
Quick Start
In this Guide
Unpacking and Inspection
Installation Environment
User Safety
Installation
- Compliant Installation
- Wall Mounting
- Rack Mounting (Optional Feature)
- Adit 3104, 3200, 3300 and 3400 Battery Backup
Chassis Overview
Interface Connectors
Reset Button
Alarm/Status LEDs
Web-Based Management
Setting up a CLI Connection
Log in
Key Enabled Software Features
Basic Configuration
1. Inspect containers for damage during shipment. Report any damage to the freight carrier for
possible insurance claims.
2. Compare packing list with office records. Report any discrepancies to the office.
3. Open shipping containers, be careful not to damage contents.
4. Inspect contents and report any damage.
5. If equipment must be returned for any reason, carefully repack equipment in the original
shipping container with original packing materials if possible.
6. If equipment is to be installed later, replace equipment in original shipping container and store
in a safe place until ready to install.
Electrostatic Discharge (ESD) Precautions
ESD can damage processors, circuit cards, and other electronic components. Always
observe the following precautions before installing a system component.
1. Do not remove a component from its protective packaging until ready to
install it.
2. Wear a wrist grounding strap and attach it to a metal part of the system unit
before handling components. If a wrist strap is not available, maintain contact with the system
unit throughout any procedure requiring ESD protection.
The ESD warning label appears on packages and storage bags that contain static-sensitive products and
components.
Installation Environment
The environment in which you are installing the Adit 3000 must meet the following conditions:
z Operating temperature range: 32° to 104° F (0° to 40° C)
z Storage temperature range: -40° to158° F (-40° to 70° C)
z Maximum operating altitude: 10,000 ft. (3,048 m)
z Maximum non-operating altitude: 40,000 ft. (12,192 m)
z Relative humidity (non-condensing) range: 0 to 95%
WARNING! THE ADIT 3000 ISDESIGNEDFORWALLANDRACKMOUNTINGONLY. ITISNOT
DESIGNEDFORDESKTOPUSE.
4Adit 3200 - Release 1.6
Page 5
Quick Start
User Safety
User Safety
CAUTION! WHEN USING YOUR TELEPHONE EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD
ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE
INCLUDING THE FOLLOWING:
z Do not use this product near water for example, near a bathtub, washbowl, kitchen sink or
laundry tub, in a wet basement or near a swimming pool.
z Avoid using a telephone (other than a cordless type) during an electrical storm. There may be
a remote risk of electric shock from lightning.
z Do not use the telephone to report a gas leak in the vicinity of the leak.
z Use only the power cord and batteries indicated in this manual. Do not dispose of batteries in a
fire. They may explode. Check with local codes for possible special disposal instructions.
z Refer to the installation section of this manual for a safe and proper installation procedure. All
wiring external to this equipment should follow the current provision of the National Electrical
Code.
, ELECTRIC SHOCK AND INJURY TO PERSONS,
Installation
The following are instructions for a compliant installation of the Adit 3200. Please note the following
warnings, before installing the unit.
For wall and rack mount instructions, use the links listed below to the appropriate section:
z Wall Mounting
z Rack Mounting (Optional Feature)
WARNING! OBSERVEPRECAUTIONSFORHANDLINGELECTROSTATICDEVICES. SEE
SHALLBEPERMANENTLYCONNECTEDTOEARTH. SEEGrounding the UnitONPAGE 12.
4. Connect DS1 (T1) and Ethernet connectors as needed.
5. Connect RS-232 connector and open Terminal Emulator software on your PC. Note: With this
connected first, the boot process can be monitored.
6. Connect Power to the unit.
7. Monitor the boot process on your PC, when complete the status light should be green.
8. For any software enabled features, enter the key command. See the key command in the Adit
3000 CLI Reference Manual, for detailed information.
9. To verify use the show version command.
10. Now you can proceed to provisioning the unit. See Basic Configuration on page 22 for
information.
6Adit 3200 - Release 1.6
Page 7
Quick Start
Mounting Bracket
Leave adequate space
at the front/back for
access to connectors
Back of unit
Front of unit
Installation
Wall Mounting
Before beginning the mounting process, verify that the installation area is a stable environment, clean
and free from extremes of temperature, shock, vibration and EMI. See Installation Environment on
page 4.
The Adit 3000 is delivered with mounting brackets that can easily be attached for quick and easy wall
mounting, as shown in the illustration above.
To install the unit to the wall:
1. Attach the wall mount brackets to the Adit 3000, with wall attachment flange pointing away
from the unit, as shown above. Attach with 4 screws provided (2 for each bracket).
2. Mount the unit to the wall using appropriate mounting screws (not included). Note: it is
acceptable to mount on drywall with suitable anchor-type mounting screws.
NOTE: The Adit 3000 must be mounted with the brackets on the top and bottom, as shown
above.
Adit 3200 - Release 1.67
Page 8
Quick Start
23 in rack
19 in rack
Front
Front
screws
screws
screws
screws
Rack Mount Tray
Rack Mount Tray
Mounting Ear
Mounting EarMounting Ear
Mounting Ear
Mounting Ear
Rack Mounting Tray
Installation
Rack Mounting (Optional Feature)
NOTE: Rack mounting kits are available for both 19 and 23 inch racks. 1 Rack Unit (RU) of
spacing is required above the Adit 3000 in the Rack Mount Unit.
To rack mount the Adit 3000, follow the instructions below:
1. Attach bracket ears to Rack Mounting Tray using four #10-32 x 1/4” screws on each side. The
Mounting Ears can be used for both a 19 or 23 inch rack. The drawing below shows a top view
of the 2 versions.
8Adit 3200 - Release 1.6
2. Attach the Rack Mounting Tray assembly (with mounting ears attached) to rack, using four
#10-32 x 1/4” screws (two on each mounting ear).
3. Remove wall mount and screws, if attached, from Adit 3000 unit.
Note: Adit 3000 and wall mounting bracket are not assembled from the factory.
Page 9
Quick Start
Tray Slide
screws
screws
Installation
4. Place the Adit on the Tray Slide and attach with 4 screws removed in step 2.
5. Slide the assembled piece (Adit 3000 and Tray Slide) onto the installed Rack Mounting Tray.
6. Secure the Tray Slide to the Rack Mounting Tray with the attached screws on the Tray Slide.
Adit 3200 - Release 1.69
Page 10
Quick Start
Installation
Adit 3104, 3200, 3300 and 3400 Battery Backup
The Adit 3104, 3200, 3300 and 3400 Battery Backup (P/N 730-0132), is a wall-mount battery backup
unit to provide up to 8 hours battery backup.
Please see the Battery Backup User Manual for product information and installation instructions, which
is provided with unit.
Note: This is an optional feature.
10Adit 3200 - Release 1.6
Page 11
Quick Start
(1) 10/100Base-T
Ethernet (WAN)
(4) 10/100Base-T
Ethernet (LAN)
Alarm
Status
Reset
RS-232
Management
Port
Power/Battery/Status
Ground
Back
Front
(1) DS1/E1 (WAN)
(E1-future)
Chassis Overview
Chassis Overview
Adit 3200 - Release 1.611
Page 12
Quick Start
Chassis
Ground
Interface Connectors
Interface Connectors
The following are the Adit 3200 interface connectors:
Front of Adit
z (1) DS1 WAN port (RJ-48C). Note: E1 will be in a future release.
z (1) 10/100Base-T WAN port (RJ-45)
z (4) 10/100Base-T switched LAN ports (RJ-45)
Back of Adit
z RS-232 craft port connector for local management
z Power input connector
z Ground connector
Grounding the Unit
WARNING! THE ADIT 3200 ISREQUIREDTOBEPERMANENTLYGROUNDEDFORTHE
PROTECTIONOFUSERSANDSERVICEPERSONNEL.
Chassis ground is located on the back of the unit.
To ground the unit:
1. Connect a minimum 14 AWG ground
wire with a #8 ring tongue terminal (not
included) to the chassis ground on the
back of the unit. Secure with the 8-32
screw and lock washer provided.
2. Connect the opposite end of the ground
wire to a suitable earth grounding point
such as a building grounding electrode,
metal water pipe, or metal building
structure that is in compliance with article 250 of NEC.
12Adit 3200 - Release 1.6
Page 13
Quick Start
PIN 10 , ORANGE
PIN 5, BLACK
Interface Connectors
Power
The Adit 3000 is powered by a limited -48 VDC Power source. The
following options are available:
z AC/DC Converter
z Battery Backup module
AC/DC Converter
An AC/DC Converter generates 48VDC from any worldwide AC power source.
To connect AC power:
1. Plug power connector from AC/DC converter into rear of Adit 3000.
2. Connect AC/DC converter to wall outlet.
3. A green light should appear on the Status LED on the front of the unit.
The Adit 3000 Battery connection is provided for Battery Backup. See Adit 3104, 3200, 3300 and 3400
Battery Backup on page 8 for additional information.
Adit 3200 - Release 1.613
Page 14
Quick Start
15
69
Interface Connectors
RS-232 Craft Port (Female DB-9)
The RS-232 craft port connector (female) is for connection to an external PC or Hayes-compatible
modem for local or remote configuration, management, and performance monitoring using the Adit
3000 Command Line Interface (CLI).
The RS-232 craft port connects via a female DB-9 connector on the Adit
3000.
The pinouts are as follows:
Pin NumberDirectionDescription
1OutboundCarrier Detect
2OutboundReceive Data
3InboundTransmit Data
4InboundData Terminal Ready
5N/ASignal Ground
6OutboundData Set Ready
7InboundRequest to Send
8OutboundClear to Send
9N/CNot connected
14Adit 3200 - Release 1.6
Page 15
Quick Start
18
Interface Connectors
DS1/E1 Connection Ports
Each DS1/E1 connection port is equipped with a standard RJ-48C (female) on the
Adit 3000 unit. Note: E1 will be available in a future release.
The pinouts are as follows:
DS1/E1 RJ-48C
The pinouts are as follows:
Note: This is a hub pinout, you will need a straight cable to connect to a PC.
OffOff line
GreenNormal
RedLoss of Signal (LOS)
YellowBipolar Violation (BPV)
Flashing GreenLoopback active
Flashing YellowYellow Alarm (Remote Alarm Indication)
Flashing Red (Slow)Loss of Frame (LOF) or Alarm Indication Signal (AIS)
Flashing Red (Fast)Self-test Failure
Adit 3200 - Release 1.615
Page 16
Quick Start
18
8 1
Reset Button
10/100Base-TX Ethernet
The 10/100Base-TX Ethernet (female) ports provide connectivity for Router
WAN and/or LAN ports and for management connection via Telnet and/or
SNMP to a Network Management System.
Ethernet (RJ-45)
The pinouts are as follows:
Pin Name Description
1 Receive +Receive from network
2 Receive -Receive from network
3 Transmit + Transmit to network
4-5 N/CNot connected
6 Transmit - Transmit to network
7-8N/CNot connected
The LEDs are as follows:
LEDStateDescription
Left LEDThe left LED shall show Link Status.
Right LEDThe right LED shall indicate Link Speed.
Reset Button
The system can be reset by pressing the reset button located on the front panel.
OffLink Down
GreenLink Up
Flashing GreenTraffic on Link
YellowCollision status
Off10 Mbit/sec, down or not connected
Green100 Mbit/sec
user-configured manor environmental inputs, DS1 short, DS1 open, DS1
facility alarm, DS1 RAI, DS1 AIS, DS1 LOF, DS1 LOS, WAN fault,
Ethernet fault and dead card alarms.
MinorOffNo minor alarms present
RedMinor alarms present. Minor alarms include:
user-configured minor environmental inputs, DS1 excessive line code
violations.
StatusOffNo power to system
GreenApplication running, no detected system problems.
Green FlashingPower-On Self Test (POST) successful. System booted. Loading
Application.
Green/YellowFlashing alternate colors. Application Self Test in Process.
YellowYellow while booting. If this stays a steady yellow the Power-On Self Test
(POST) failed.
Yellow FlashingPower-On Self Test (POST) In Process.
RedSystem Failure
Adit 3200 - Release 1.617
Page 18
Quick Start
Web-Based Management
Web-Based Management
The web-based management interface allows you to control various system parameters. The interface
is accessed through a web browser.
To access the management console:
NOTE: The following assumes that you have connected the PC to the LAN port of the Adit
3200.
1. Launch a web browser on your PC in the LAN to which the Adit 3000’s LAN port is connected.
Note: If connection to the 3000 is to be through an Ethernet or T1 WAN, the remote admin
WAN access must be enabled with the following command sequence:
CommandDescription
Username: admin
Password: ********
Adit 3200> enableEnter the Privileged mode.
Password: ********Enter password for the Privileged mode.
#configure terminalEnter the Configuration mode.
(config)# remote-admin web
primary-port enable
Log into the system (username and password).
Enable remote web admin.
2. Type the Adit 3000’s IP address or name in the address bar.
Example: http://192.168.1.1.
z Default IP address is http://192.168.1.1
Note: to display the current IP address of the systems, use the following CLI command:
3. Login to the unit.
Enter User Name and Password. Note: these setting should be changed from the default settings
after the initial login.
z Default user name is admin
z Default password is admin 123
NOTE: After a few minutes of inactivity, the session will automatically timeout and the
operator will be required to log in to continue the session.
WARNING! IFYOUR USER NAMEAND PASSWORDARESETTOTHEDEFAULTSETTING, ITIS
RECOMMENDEDTHATYOUMODIFYTHEMFORSECURITYPURPOSES.
18Adit 3200 - Release 1.6
Page 19
Quick Start
Setting up a CLI Connection
Setting up a CLI Connection
A CLI connection will require the LAN or WAN IP address of the unit. Note: If the WAN IP address
is used, the remote admin WAN access must be enabled with the following command sequence:
CommandDescription
Username: admin
Password: ********
Adit 3200> enableEnter the Privileged mode.
Password: ********Enter password for the Privileged mode.
#configure terminalEnter the Configuration mode.
(config)# remote-admin web
primary-port enable
Log into the system (username and password).
Enable remote web admin.
NOTE: For Adit 3200 CLI commands see the Adit 3000 CLI Reference Manual. This is a
separate document and can be found on the CD that is provided with the product, or on the
Carrier Access customer website.
To connect with CLI, set up the connection:
z If connecting via the Ethernet 100Base-TX connection, use a Telnet TCP/IP program to access
the CLI. This requires an IP address of the unit.
Note: to display the current IP address of the unit, use the ifconfig command.
z If connecting via RS-232, the port settings should be set to:
Bits per second: 115200 Data bits: 8
Parity: None Stop bits: 1
Flow control: None
z Set your Terminal Emulation to: VT100
NOTE: When using Tera Term (Telnet program) TCP/IP, CLI commands will not be
recognized until the following setup is completed.
z In Tera Term go to Setup/Terminal
z Set the New-line/Transmit value CR+LF
Adit 3200 - Release 1.619
Page 20
Quick Start
Log in
Log in
After successful connection, via telnet or HyperTerm, the user must login. Default Logins are:
After successful login the prompt will be displayed as follows:
NOTE: It is recommended that you change your password from the default.
Login: admin
Password: admin123
Adit 3200>
20Adit 3200 - Release 1.6
Page 21
Quick Start
Key Enabled Software Features
Key Enabled Software Features
The Adit 3200 has additional features that are not provided on the base system. These features can be
purchased with the product or added later as needed. These features are enabled via a Software Key
(example: G.729). The number of keyed features may expand with the development of the product,
therefore to see a list of current keyed features, or to purchase a key, contact Carrier Access Customer
Service or Sales.
To enter a software key, use the following CLI command:
Syntax:
Example: (config)# key cxusdfutkj3diosn412C
NOTE: Keys may only be entered through the CLI (not through the GUI).
The Key Enabled Software Features are displayed on the Advanced/Technical Information window.
(config)# key {key-code}
This information is also displayed with the following CLI command:
The following configuration is divided into logical sections, where each section configures an additional
function. The first must be configured before the second and so forth, however, you may stop at any
section and not add the following feature.
NOTE: The order in which commands are entered can affect the successful provisioning of
the Adit 3200.
z Setup Adit 3200 for access via Web-Browser
z Restore Factory Defaults
z Modify Default Admin User
z Configure Ethernet WAN Interface
z Configure Serial 1 as WAN
Setup Adit 3200 for access via Web-Browser
The following steps will configure the Adit 3200 to allow access to the Web Browser for configuration,
through one of the 4 10/100Base-T LAN connections.
Note: for LAN access, no additional configuration is required to access the Adit using the web browser.
To configure the WAN access:
1. Connect to the CLI via the DB-9 RS-232. See Setting up a CLI Connection on page 19.
2. Enable the remote admin WAN access with the following command sequence:
CommandDescription
Username: admin
Password: ********
Adit 3200> enableEnter the Privileged mode.
Password: ********Enter password for the Privileged mode.
#configure terminalEnter the Configuration mode.
(config)# remote-admin web
primary-port enable
Log into the system (username and password).
Enable remote web admin.
22Adit 3200 - Release 1.6
Page 23
Quick Start
Basic Configuration
Restore Factory Defaults
If the unit is not out-of-the-box, you may want to verify that the unit is set to defaults. Note: This will
reset the IP address back to the default setting of 192.168.1.1.
In the web-browser:
z Select Advanced from the Navigation bar
z Select Restore Defaults
z Select OK to restore defaults
Adit 3200 - Release 1.623
Page 24
Quick Start
Basic Configuration
Modify Default Admin User
For security purposes it is recommended that the Administrator User be changed from the default
settings.
Modify the Administrator User in the web-browser:
z Select Advanced from the Navigation bar
z Select Users icon
z Select Administrator, to open the profile.
24Adit 3200 - Release 1.6
Page 25
Quick Start
Basic Configuration
z Modify the User information, and select OK to save. It is important to note that you need to
have a minimum of one user with Administrative Privileges. For users with other access
levels, add a New User.
Note: For security purposes, the password should be changed.
z You will be required to login again, if you have modified the User Profile that you are logged
in with.
Adit 3200 - Release 1.625
Page 26
Quick Start
Basic Configuration
Configure Ethernet WAN Interface
In the web-browser:
1. Select Network Connections from the Navigation bar.
2. It is recommended that you disable/delete the Serial1 port.
3. Select (click) Ethernet 2 (WAN Ethernet) connection to configure.
4. Select the Enable button, to configure the WAN Ethernet up (or in-service).
5. Select the Settings button.
26Adit 3200 - Release 1.6
Page 27
Quick Start
Basic Configuration
6. Set Internet Protocol to Obtain an IP Address Automatically, from the pulldown menu. This
will enable the Adit 3200 as a DHCP Client. Leave the other fields to their default settings.
7. Select Apply to apply the new settings.
Adit 3200 - Release 1.627
Page 28
Quick Start
Basic Configuration
Configure Serial 1 as WAN
In the web-browser:
1. Select Network Connections from the Navigation bar.
2. Select Serial 1.
3. Select Settings button.
4. Set Network to WAN.
5. Select Apply to apply the new settings.
28Adit 3200 - Release 1.6
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.