Part Number: 002-0246-0010
Product Release: 1.6
September 2007
Copyright 2007 Carrier Access Corporation. All rights reserved.
The information presented in this manual is subject to change without notice and does not represent a commitment on the
part of Carrier Access Corporation. The hardware and software described herein are furnished under a license or nondisclosure agreement. The hardware, software, and manual may be used or copied only in accordance with the terms of this
agreement. It is against the law to reproduce, transmit, transcribe, store in a retrieval system, or translate into any medium
- electronic, mechanical, magnetic, optical, chemical, manual, or otherwise - any part of this manual or software supplied
with the Adit 3200 for any purpose other than the purchaser’s personal use without the express written permission of
Carrier Access Corporation.
The Carrier Access Logo and Adit are registered trademarks of Carrier Access Corporation. All other brand or product
names are trademarks or registration trademarks of their respective companies or organizations.
Contact Information:
Carrier Access Corporation
5395 Pearl Parkway
Boulder, CO 80301-2490
Corporate Phone: (303) 442-5455
Fax: (303) 443-5908
www.carrieraccess.com
Customer Support Direct: (800) 786-9929
E-mail: tech-support@carrieraccess.com
QUICK START GUIDE
Quick Start
In this Guide
Unpacking and Inspection
Installation Environment
User Safety
Installation
- Compliant Installation
- Wall Mounting
- Rack Mounting (Optional Feature)
- Adit 3104, 3200, 3300 and 3400 Battery Backup
Chassis Overview
Interface Connectors
Reset Button
Alarm/Status LEDs
Web-Based Management
Setting up a CLI Connection
Log in
Key Enabled Software Features
Basic Configuration
1. Inspect containers for damage during shipment. Report any damage to the freight carrier for
possible insurance claims.
2. Compare packing list with office records. Report any discrepancies to the office.
3. Open shipping containers, be careful not to damage contents.
4. Inspect contents and report any damage.
5. If equipment must be returned for any reason, carefully repack equipment in the original
shipping container with original packing materials if possible.
6. If equipment is to be installed later, replace equipment in original shipping container and store
in a safe place until ready to install.
Electrostatic Discharge (ESD) Precautions
ESD can damage processors, circuit cards, and other electronic components. Always
observe the following precautions before installing a system component.
1. Do not remove a component from its protective packaging until ready to
install it.
2. Wear a wrist grounding strap and attach it to a metal part of the system unit
before handling components. If a wrist strap is not available, maintain contact with the system
unit throughout any procedure requiring ESD protection.
The ESD warning label appears on packages and storage bags that contain static-sensitive products and
components.
Installation Environment
The environment in which you are installing the Adit 3000 must meet the following conditions:
z Operating temperature range: 32° to 104° F (0° to 40° C)
z Storage temperature range: -40° to158° F (-40° to 70° C)
z Maximum operating altitude: 10,000 ft. (3,048 m)
z Maximum non-operating altitude: 40,000 ft. (12,192 m)
z Relative humidity (non-condensing) range: 0 to 95%
WARNING! THE ADIT 3000 ISDESIGNEDFORWALLANDRACKMOUNTINGONLY. ITISNOT
DESIGNEDFORDESKTOPUSE.
4Adit 3200 - Release 1.6
Quick Start
User Safety
User Safety
CAUTION! WHEN USING YOUR TELEPHONE EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD
ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE
INCLUDING THE FOLLOWING:
z Do not use this product near water for example, near a bathtub, washbowl, kitchen sink or
laundry tub, in a wet basement or near a swimming pool.
z Avoid using a telephone (other than a cordless type) during an electrical storm. There may be
a remote risk of electric shock from lightning.
z Do not use the telephone to report a gas leak in the vicinity of the leak.
z Use only the power cord and batteries indicated in this manual. Do not dispose of batteries in a
fire. They may explode. Check with local codes for possible special disposal instructions.
z Refer to the installation section of this manual for a safe and proper installation procedure. All
wiring external to this equipment should follow the current provision of the National Electrical
Code.
, ELECTRIC SHOCK AND INJURY TO PERSONS,
Installation
The following are instructions for a compliant installation of the Adit 3200. Please note the following
warnings, before installing the unit.
For wall and rack mount instructions, use the links listed below to the appropriate section:
z Wall Mounting
z Rack Mounting (Optional Feature)
WARNING! OBSERVEPRECAUTIONSFORHANDLINGELECTROSTATICDEVICES. SEE
SHALLBEPERMANENTLYCONNECTEDTOEARTH. SEEGrounding the UnitONPAGE 12.
4. Connect DS1 (T1) and Ethernet connectors as needed.
5. Connect RS-232 connector and open Terminal Emulator software on your PC. Note: With this
connected first, the boot process can be monitored.
6. Connect Power to the unit.
7. Monitor the boot process on your PC, when complete the status light should be green.
8. For any software enabled features, enter the key command. See the key command in the Adit
3000 CLI Reference Manual, for detailed information.
9. To verify use the show version command.
10. Now you can proceed to provisioning the unit. See Basic Configuration on page 22 for
information.
6Adit 3200 - Release 1.6
Quick Start
Mounting Bracket
Leave adequate space
at the front/back for
access to connectors
Back of unit
Front of unit
Installation
Wall Mounting
Before beginning the mounting process, verify that the installation area is a stable environment, clean
and free from extremes of temperature, shock, vibration and EMI. See Installation Environment on
page 4.
The Adit 3000 is delivered with mounting brackets that can easily be attached for quick and easy wall
mounting, as shown in the illustration above.
To install the unit to the wall:
1. Attach the wall mount brackets to the Adit 3000, with wall attachment flange pointing away
from the unit, as shown above. Attach with 4 screws provided (2 for each bracket).
2. Mount the unit to the wall using appropriate mounting screws (not included). Note: it is
acceptable to mount on drywall with suitable anchor-type mounting screws.
NOTE: The Adit 3000 must be mounted with the brackets on the top and bottom, as shown
above.
Adit 3200 - Release 1.67
Quick Start
23 in rack
19 in rack
Front
Front
screws
screws
screws
screws
Rack Mount Tray
Rack Mount Tray
Mounting Ear
Mounting EarMounting Ear
Mounting Ear
Mounting Ear
Rack Mounting Tray
Installation
Rack Mounting (Optional Feature)
NOTE: Rack mounting kits are available for both 19 and 23 inch racks. 1 Rack Unit (RU) of
spacing is required above the Adit 3000 in the Rack Mount Unit.
To rack mount the Adit 3000, follow the instructions below:
1. Attach bracket ears to Rack Mounting Tray using four #10-32 x 1/4” screws on each side. The
Mounting Ears can be used for both a 19 or 23 inch rack. The drawing below shows a top view
of the 2 versions.
8Adit 3200 - Release 1.6
2. Attach the Rack Mounting Tray assembly (with mounting ears attached) to rack, using four
#10-32 x 1/4” screws (two on each mounting ear).
3. Remove wall mount and screws, if attached, from Adit 3000 unit.
Note: Adit 3000 and wall mounting bracket are not assembled from the factory.
Quick Start
Tray Slide
screws
screws
Installation
4. Place the Adit on the Tray Slide and attach with 4 screws removed in step 2.
5. Slide the assembled piece (Adit 3000 and Tray Slide) onto the installed Rack Mounting Tray.
6. Secure the Tray Slide to the Rack Mounting Tray with the attached screws on the Tray Slide.
Adit 3200 - Release 1.69