SAFETY CONSIDERATIONS
Installing, starting up, and servicing air- conditioning equipment
can be hazardous due to system pressures, electrical components,
and equipment location (roofs, elevated structures, etc.).
Only trained, qualified installers and service mechanics should
install, start- up, and service this equipment.
Untrained personnel can perform basic maintenance functions
such as cleaning coils. All other operations should be performed
by trained service personnel.
When working on the equipment, observe precautions in the
literature and on tags, stickers, and labels attached to the
equipment.
Follow all safety codes. Wear safety glasses and work gloves.
Keep a quenching cloth and fire extinguisher nearby when
brazing. Use care in handling, rigging, and setting bulky
equipment.
Read these instructions thoroughly and follow all warnings or
cautions included in literature and attached to the unit. Consult
local building codes and National Electrical Code (NEC) for
special requirements. Recognize safety information. This is the
!
!
safety- alert symbol
in instructions or manuals, be alert to the potential for personal
injury. Understand these signal words: DANGER, WARNING,
and CAUTION. These words are used with the safety- alert
symbol. DANGER identifies the most serious hazards which will
result in severe personal injury or death. WARNING signifies
hazards which could result in personal injury or death. CAUTION
is used to identify unsafe practices which may result in minor
personal injury or product and property damage. NOTE is used to
highlight suggestions which will result in enhanced installation,
reliability, or operation.
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or
death.
Before beginning any modification or installation of this kit, be
sure the main electrical disconnect is in the OFF position.
Ensure power is disconnected to the fan coil unit. On some
systems both the fan coil and the outdoor unit may be on the
same disconnect. Tag the disconnect switch with a suitable
warning label. There may be more than one disconnect.
EQUIPMENT DAMAGE HAZARD
Failure to follow this warning may result in equipment
damage.
Do not install wired controller in an area subjected to excessive
steam, oil or sulfide gas. Doing so may cause the controller to
deform and/or fail.
. When you see this symbol on the unit and
!
!
WARNING
CAUTION
Wired Remote Controller
Ductless Split Systems
Kit Contents: Confirm that all the following parts are included.
No. Description Qty Remarks
1 Wired Remote Controller 1 n/a
Installation and owner’s
2
manual
3 Screws 3
4 Wall plugs 3 For wall mounting
5 Screws 2
6 Plastic screw bars 2
7 Theconnectivewiresgroup 1 24AWG
Field Supplied Components: Prepare the following on site.
Description
Switch Box 1 n/a n/a
Wiring Tube
(insulating sleeve and
tightening screw)
S This manual contains installation procedures for the wire
controller only. Refer to the indoor unit Installation Manual for
connecting the Wire Controller and the Indoor Unit.
S Install the wire joint (5p) to the appointed position of the electric
controlling box.
S The wired controller circuit is a low voltage circuit. Never
connect it with a standard 220V/380V circuit or place it in the
same wiring tube as the circuit. The interval must be more than
11.8- 19.7in. (300~500mm).
S The shield cable must be connected stable to the ground or the
transmission may fail.
S Do not extend the shield cable by cutting. If necessary, use a
Terminal Connection Block to connect.
S After finishing the connection, do not use a Meggar to perform
the installation check to the signal wire.
Qty
1 n/a n/a
1 n/a
M4X20 (for mounting on the wall)
M4X25 (for mounting on the wall)
For fixing on the
switch box
Type Remarks
CONTROLLER INDICATOR NAMES AND FUNCTIONS
1. OPERATION MODE INDICATION
Press the MODE button to select the following modes: AUTO,
COOL, DRY, HEAT, FAN ONLY, and AUTO. The HEAT mod e
does not exist on the cooling only model.
2.TIMER
Adjust the ON time or ONLY ON time setting and the ON
indicator displays. Adjust the OFF time or the ONLY OFF time
and the OFF indicator displays. If the ON and OFF timer are both
set, both the ON and OFF indicators display.
3. FOLLOW ME
After the temperature is set, the temperature sensor inside the wire
controller compares the two temperatures. The air temperature
around the wire controller determines the unit’s temperature
setting. This function is available in the COOLING, HEATING,
and AUTO modes.
4. ON/OFF INDICATOR
The icon displays when the indicator is on.
5. FAN SPEED INDICATOR
There are four fan modes: low, middle, high, and auto.
NOTE: Some models do not have the middle fan option.
6. LOCK
Press the “LOCK” button to disable the other buttons. Press again
to enable the other buttons.
7. TEMPERATURE DISPLAY ZONE
The zone displays the set temperature. Press the
buttons to adjust the setting. In the fan mode, the temperature
button does not appear.
YBtemperature